Cargando…
Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report
Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomogr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127856/ https://www.ncbi.nlm.nih.gov/pubmed/35619750 http://dx.doi.org/10.1177/2050313X221100874 |
_version_ | 1784712443702804480 |
---|---|
author | Miyata, Jun Dateoka, Kaname Yoshioka, Tetsuya |
author_facet | Miyata, Jun Dateoka, Kaname Yoshioka, Tetsuya |
author_sort | Miyata, Jun |
collection | PubMed |
description | Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomography, showing soft tissue opacity between the tip of the tracheostomy tube and the bronchi. A movable mass in the trachea, identified as mucus by pathological examination, was removed using bronchoscopy. Acute airway obstruction by a mucus plug potentially occurred with a long history of insertion of a tracheostomy tube. Emergency imaging studies and bronchoscopy were useful for management. |
format | Online Article Text |
id | pubmed-9127856 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-91278562022-05-25 Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report Miyata, Jun Dateoka, Kaname Yoshioka, Tetsuya SAGE Open Med Case Rep Case Report Acute airway obstruction long after tracheostomy has rarely been reported. An 81-year-old Japanese woman with a tracheostomy tube for 12 years developed a 2-day history of coughing-up sputum with difficulty, foreign body sensation, and mild dyspnea. Dyspnea worsened immediately after computed tomography, showing soft tissue opacity between the tip of the tracheostomy tube and the bronchi. A movable mass in the trachea, identified as mucus by pathological examination, was removed using bronchoscopy. Acute airway obstruction by a mucus plug potentially occurred with a long history of insertion of a tracheostomy tube. Emergency imaging studies and bronchoscopy were useful for management. SAGE Publications 2022-05-20 /pmc/articles/PMC9127856/ /pubmed/35619750 http://dx.doi.org/10.1177/2050313X221100874 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Report Miyata, Jun Dateoka, Kaname Yoshioka, Tetsuya Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title | Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title_full | Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title_fullStr | Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title_full_unstemmed | Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title_short | Acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: A case report |
title_sort | acute airway obstruction by a mucus plug in a patient with a 12-year history of inserting a double cannula tracheostomy tube: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9127856/ https://www.ncbi.nlm.nih.gov/pubmed/35619750 http://dx.doi.org/10.1177/2050313X221100874 |
work_keys_str_mv | AT miyatajun acuteairwayobstructionbyamucuspluginapatientwitha12yearhistoryofinsertingadoublecannulatracheostomytubeacasereport AT dateokakaname acuteairwayobstructionbyamucuspluginapatientwitha12yearhistoryofinsertingadoublecannulatracheostomytubeacasereport AT yoshiokatetsuya acuteairwayobstructionbyamucuspluginapatientwitha12yearhistoryofinsertingadoublecannulatracheostomytubeacasereport |