Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis

BACKGROUND: To determine the repeatability and agreement using corneal tomography of a swept-source optical coherence tomographer (SS-OCT) compared to a rotating Scheimpflug camera (RSC) in normal eyes and keratoconus (KC) eyes. METHODS: This prospective repeatability analysis was performed at the D...

Descripción completa

Detalles Bibliográficos
Autores principales: Herber, Robert, Lenk, Janine, Pillunat, Lutz E., Raiskup, Frederik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9128256/
https://www.ncbi.nlm.nih.gov/pubmed/35606839
http://dx.doi.org/10.1186/s40662-022-00290-6
_version_ 1784712526600077312
author Herber, Robert
Lenk, Janine
Pillunat, Lutz E.
Raiskup, Frederik
author_facet Herber, Robert
Lenk, Janine
Pillunat, Lutz E.
Raiskup, Frederik
author_sort Herber, Robert
collection PubMed
description BACKGROUND: To determine the repeatability and agreement using corneal tomography of a swept-source optical coherence tomographer (SS-OCT) compared to a rotating Scheimpflug camera (RSC) in normal eyes and keratoconus (KC) eyes. METHODS: This prospective repeatability analysis was performed at the Department of Ophthalmology of University Hospital Carl Gustav Carus, Dresden, Germany. Forty-three normal and 57 KC eyes were enrolled in the study. Three consecutive measurements were performed by the same operator on each device. Corneal parameters of anterior and posterior corneal surface, such as simulated keratometry (SimK), as well as central and thinnest corneal thickness were evaluated. Repeatability and agreement were assessed by using the coefficient of repeatability and Bland-Altman analysis. RESULTS: The repeatability of anterior corneal parameters was comparable between RSC and SS-OCT in normal eyes (repeatability < 0.5 D). Repeatability was increased in mild and moderate KC for all parameters using both devices. In moderate KC, repeatability of Kmax was 1.33 D and 0.78 D for RSC and SS-OCT, respectively. Repeatability of posterior corneal parameters was consistently better for SS-OCT. Significant offsets and wide ranges of limits of agreement were found between the devices for SimK and corneal thickness values. CONCLUSIONS: SS-OCT showed highly repeatable measurements of anterior and posterior corneal parameters in normal and KC eyes. Compared to RSC, the SS-OCT had a better repeatability of anterior corneal parameters in mild and moderate KC as well as posterior corneal parameters in all groups. Both devices should not be used interchangeably in the diagnostic process of patients. Trial registration NCT04251143 at Clinicaltrials.gov, registered on 12 March 2018, https://clinicaltrials.gov/ct2/show/NCT04251143?cond=Keratoconus&cntry=DE&city=Dresden&draw=2&rank=1 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-022-00290-6.
format Online
Article
Text
id pubmed-9128256
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91282562022-05-25 Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis Herber, Robert Lenk, Janine Pillunat, Lutz E. Raiskup, Frederik Eye Vis (Lond) Research BACKGROUND: To determine the repeatability and agreement using corneal tomography of a swept-source optical coherence tomographer (SS-OCT) compared to a rotating Scheimpflug camera (RSC) in normal eyes and keratoconus (KC) eyes. METHODS: This prospective repeatability analysis was performed at the Department of Ophthalmology of University Hospital Carl Gustav Carus, Dresden, Germany. Forty-three normal and 57 KC eyes were enrolled in the study. Three consecutive measurements were performed by the same operator on each device. Corneal parameters of anterior and posterior corneal surface, such as simulated keratometry (SimK), as well as central and thinnest corneal thickness were evaluated. Repeatability and agreement were assessed by using the coefficient of repeatability and Bland-Altman analysis. RESULTS: The repeatability of anterior corneal parameters was comparable between RSC and SS-OCT in normal eyes (repeatability < 0.5 D). Repeatability was increased in mild and moderate KC for all parameters using both devices. In moderate KC, repeatability of Kmax was 1.33 D and 0.78 D for RSC and SS-OCT, respectively. Repeatability of posterior corneal parameters was consistently better for SS-OCT. Significant offsets and wide ranges of limits of agreement were found between the devices for SimK and corneal thickness values. CONCLUSIONS: SS-OCT showed highly repeatable measurements of anterior and posterior corneal parameters in normal and KC eyes. Compared to RSC, the SS-OCT had a better repeatability of anterior corneal parameters in mild and moderate KC as well as posterior corneal parameters in all groups. Both devices should not be used interchangeably in the diagnostic process of patients. Trial registration NCT04251143 at Clinicaltrials.gov, registered on 12 March 2018, https://clinicaltrials.gov/ct2/show/NCT04251143?cond=Keratoconus&cntry=DE&city=Dresden&draw=2&rank=1 SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40662-022-00290-6. BioMed Central 2022-05-23 /pmc/articles/PMC9128256/ /pubmed/35606839 http://dx.doi.org/10.1186/s40662-022-00290-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Herber, Robert
Lenk, Janine
Pillunat, Lutz E.
Raiskup, Frederik
Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title_full Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title_fullStr Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title_full_unstemmed Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title_short Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
title_sort comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9128256/
https://www.ncbi.nlm.nih.gov/pubmed/35606839
http://dx.doi.org/10.1186/s40662-022-00290-6
work_keys_str_mv AT herberrobert comparisonofcornealtomographyusinganovelsweptsourceopticalcoherencetomographerandrotatingscheimpflugsysteminnormalandkeratoconuseyesrepeatabilityandagreementanalysis
AT lenkjanine comparisonofcornealtomographyusinganovelsweptsourceopticalcoherencetomographerandrotatingscheimpflugsysteminnormalandkeratoconuseyesrepeatabilityandagreementanalysis
AT pillunatlutze comparisonofcornealtomographyusinganovelsweptsourceopticalcoherencetomographerandrotatingscheimpflugsysteminnormalandkeratoconuseyesrepeatabilityandagreementanalysis
AT raiskupfrederik comparisonofcornealtomographyusinganovelsweptsourceopticalcoherencetomographerandrotatingscheimpflugsysteminnormalandkeratoconuseyesrepeatabilityandagreementanalysis