Cargando…

Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling

Traditional liver transplant strategies with cold preservation usually result in ischemia-reperfusion injury (IRI) to the donor liver. Regular normothermic machine perfusion (NMP) donor livers suffer IRI twice. Here, we aimed to introduce a novel technique called continuous NMP without recooling to...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Zhitao, Wang, Tielong, Chen, Chuanbao, Zhao, Qiang, Ma, Yihao, Guo, Yiwen, Hong, Xitao, Yu, Jia, Huang, Changjun, Ju, Weiqiang, Chen, Maogen, He, Xiaoshun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9128617/
https://www.ncbi.nlm.nih.gov/pubmed/34495016
http://dx.doi.org/10.1097/TP.0000000000003945
_version_ 1784712589821870080
author Chen, Zhitao
Wang, Tielong
Chen, Chuanbao
Zhao, Qiang
Ma, Yihao
Guo, Yiwen
Hong, Xitao
Yu, Jia
Huang, Changjun
Ju, Weiqiang
Chen, Maogen
He, Xiaoshun
author_facet Chen, Zhitao
Wang, Tielong
Chen, Chuanbao
Zhao, Qiang
Ma, Yihao
Guo, Yiwen
Hong, Xitao
Yu, Jia
Huang, Changjun
Ju, Weiqiang
Chen, Maogen
He, Xiaoshun
author_sort Chen, Zhitao
collection PubMed
description Traditional liver transplant strategies with cold preservation usually result in ischemia-reperfusion injury (IRI) to the donor liver. Regular normothermic machine perfusion (NMP) donor livers suffer IRI twice. Here, we aimed to introduce a novel technique called continuous NMP without recooling to avoid a second IRI and its application in livers from extended criteria donors. METHODS. Seven donor livers transplanted following continuous NMP without recooling, 7 donor livers transplanted following standard NMP, and 14 livers under static cold storage (SCS) were included in this study. Perioperative outcomes were recorded and analyzed between groups. RESULTS. During the NMP without a recooling procedure, all livers cleared lactate quickly to normal levels in a median time of 100 min (interquartile range, 60–180) and remained stable until the end of perfusion. In the NMP without recooling and standard NMP groups, posttransplant peak aspartate aminotransferase and alanine aminotransferase levels were both significantly lower than those in the SCS group (P = 0.0015 and 0.016, respectively). The occurrence rate of early allograft dysfunction was significantly lower in the NMP without recooling group than in the SCS group (P = 0.022), whereas there was no difference in the NMP group with or without recooling (P = 0.462). CONCLUSIONS: Our pilot study revealed a novel technique designed to avoid secondary IRI. This novel technique is shown to have at least a comparable effect on the standard NMP, although more data are needed to show its superiority in the future.
format Online
Article
Text
id pubmed-9128617
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-91286172022-05-31 Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling Chen, Zhitao Wang, Tielong Chen, Chuanbao Zhao, Qiang Ma, Yihao Guo, Yiwen Hong, Xitao Yu, Jia Huang, Changjun Ju, Weiqiang Chen, Maogen He, Xiaoshun Transplantation Original Clinical Science—Liver Traditional liver transplant strategies with cold preservation usually result in ischemia-reperfusion injury (IRI) to the donor liver. Regular normothermic machine perfusion (NMP) donor livers suffer IRI twice. Here, we aimed to introduce a novel technique called continuous NMP without recooling to avoid a second IRI and its application in livers from extended criteria donors. METHODS. Seven donor livers transplanted following continuous NMP without recooling, 7 donor livers transplanted following standard NMP, and 14 livers under static cold storage (SCS) were included in this study. Perioperative outcomes were recorded and analyzed between groups. RESULTS. During the NMP without a recooling procedure, all livers cleared lactate quickly to normal levels in a median time of 100 min (interquartile range, 60–180) and remained stable until the end of perfusion. In the NMP without recooling and standard NMP groups, posttransplant peak aspartate aminotransferase and alanine aminotransferase levels were both significantly lower than those in the SCS group (P = 0.0015 and 0.016, respectively). The occurrence rate of early allograft dysfunction was significantly lower in the NMP without recooling group than in the SCS group (P = 0.022), whereas there was no difference in the NMP group with or without recooling (P = 0.462). CONCLUSIONS: Our pilot study revealed a novel technique designed to avoid secondary IRI. This novel technique is shown to have at least a comparable effect on the standard NMP, although more data are needed to show its superiority in the future. Lippincott Williams & Wilkins 2022-09-07 2022-06 /pmc/articles/PMC9128617/ /pubmed/34495016 http://dx.doi.org/10.1097/TP.0000000000003945 Text en Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Original Clinical Science—Liver
Chen, Zhitao
Wang, Tielong
Chen, Chuanbao
Zhao, Qiang
Ma, Yihao
Guo, Yiwen
Hong, Xitao
Yu, Jia
Huang, Changjun
Ju, Weiqiang
Chen, Maogen
He, Xiaoshun
Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title_full Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title_fullStr Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title_full_unstemmed Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title_short Transplantation of Extended Criteria Donor Livers Following Continuous Normothermic Machine Perfusion Without Recooling
title_sort transplantation of extended criteria donor livers following continuous normothermic machine perfusion without recooling
topic Original Clinical Science—Liver
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9128617/
https://www.ncbi.nlm.nih.gov/pubmed/34495016
http://dx.doi.org/10.1097/TP.0000000000003945
work_keys_str_mv AT chenzhitao transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT wangtielong transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT chenchuanbao transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT zhaoqiang transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT mayihao transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT guoyiwen transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT hongxitao transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT yujia transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT huangchangjun transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT juweiqiang transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT chenmaogen transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling
AT hexiaoshun transplantationofextendedcriteriadonorliversfollowingcontinuousnormothermicmachineperfusionwithoutrecooling