Cargando…
Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9130105/ https://www.ncbi.nlm.nih.gov/pubmed/35634131 http://dx.doi.org/10.1016/j.xnsj.2022.100121 |
_version_ | 1784712916039106560 |
---|---|
author | Ohmori, Kazuo Terayama, Sei Ono, Koichiro Sakamoto, Miyuki Horikoshi, Yukie |
author_facet | Ohmori, Kazuo Terayama, Sei Ono, Koichiro Sakamoto, Miyuki Horikoshi, Yukie |
author_sort | Ohmori, Kazuo |
collection | PubMed |
description | BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw-insertion time and number of fluoroscopic observations during screw insertion between the groups. METHODS: A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. RESULTS: The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3–19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P=0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P<0.001). There were no device-related or study treatment-related adverse events in either group. CONCLUSIONS: The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted. |
format | Online Article Text |
id | pubmed-9130105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-91301052022-05-26 Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study Ohmori, Kazuo Terayama, Sei Ono, Koichiro Sakamoto, Miyuki Horikoshi, Yukie N Am Spine Soc J Clinical Studies BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw-insertion time and number of fluoroscopic observations during screw insertion between the groups. METHODS: A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. RESULTS: The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3–19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P=0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P<0.001). There were no device-related or study treatment-related adverse events in either group. CONCLUSIONS: The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted. Elsevier 2022-05-08 /pmc/articles/PMC9130105/ /pubmed/35634131 http://dx.doi.org/10.1016/j.xnsj.2022.100121 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Clinical Studies Ohmori, Kazuo Terayama, Sei Ono, Koichiro Sakamoto, Miyuki Horikoshi, Yukie Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title | Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title_full | Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title_fullStr | Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title_full_unstemmed | Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title_short | Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study |
title_sort | accuracy and safety of percutaneous pedicle screw placement using the k-wireless minimally invasive spine percutaneous pedicle screw system in japan: a randomized active controlled study |
topic | Clinical Studies |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9130105/ https://www.ncbi.nlm.nih.gov/pubmed/35634131 http://dx.doi.org/10.1016/j.xnsj.2022.100121 |
work_keys_str_mv | AT ohmorikazuo accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy AT terayamasei accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy AT onokoichiro accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy AT sakamotomiyuki accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy AT horikoshiyukie accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy |