Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study

BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Ohmori, Kazuo, Terayama, Sei, Ono, Koichiro, Sakamoto, Miyuki, Horikoshi, Yukie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9130105/
https://www.ncbi.nlm.nih.gov/pubmed/35634131
http://dx.doi.org/10.1016/j.xnsj.2022.100121
_version_ 1784712916039106560
author Ohmori, Kazuo
Terayama, Sei
Ono, Koichiro
Sakamoto, Miyuki
Horikoshi, Yukie
author_facet Ohmori, Kazuo
Terayama, Sei
Ono, Koichiro
Sakamoto, Miyuki
Horikoshi, Yukie
author_sort Ohmori, Kazuo
collection PubMed
description BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw-insertion time and number of fluoroscopic observations during screw insertion between the groups. METHODS: A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. RESULTS: The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3–19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P=0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P<0.001). There were no device-related or study treatment-related adverse events in either group. CONCLUSIONS: The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted.
format Online
Article
Text
id pubmed-9130105
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91301052022-05-26 Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study Ohmori, Kazuo Terayama, Sei Ono, Koichiro Sakamoto, Miyuki Horikoshi, Yukie N Am Spine Soc J Clinical Studies BACKGROUND: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw-insertion time and number of fluoroscopic observations during screw insertion between the groups. METHODS: A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. RESULTS: The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3–19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P=0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P<0.001). There were no device-related or study treatment-related adverse events in either group. CONCLUSIONS: The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted. Elsevier 2022-05-08 /pmc/articles/PMC9130105/ /pubmed/35634131 http://dx.doi.org/10.1016/j.xnsj.2022.100121 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Clinical Studies
Ohmori, Kazuo
Terayama, Sei
Ono, Koichiro
Sakamoto, Miyuki
Horikoshi, Yukie
Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title_full Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title_fullStr Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title_full_unstemmed Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title_short Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study
title_sort accuracy and safety of percutaneous pedicle screw placement using the k-wireless minimally invasive spine percutaneous pedicle screw system in japan: a randomized active controlled study
topic Clinical Studies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9130105/
https://www.ncbi.nlm.nih.gov/pubmed/35634131
http://dx.doi.org/10.1016/j.xnsj.2022.100121
work_keys_str_mv AT ohmorikazuo accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy
AT terayamasei accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy
AT onokoichiro accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy
AT sakamotomiyuki accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy
AT horikoshiyukie accuracyandsafetyofpercutaneouspediclescrewplacementusingthekwirelessminimallyinvasivespinepercutaneouspediclescrewsysteminjapanarandomizedactivecontrolledstudy