Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)

Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized. A printed pholcodinium (PHL)(2+)/5-nitrobarbiturate (NB)(−) ion-association complex as a sensory material-based all-solid-state io...

Descripción completa

Detalles Bibliográficos
Autores principales: Abd-Rabboh, Hisham S. M., El-Galil E. Amr, Abd, A. Elsayed, Elsayed, Sayed, Ahmed Y. A., Kamel, Ayman H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9131362/
https://www.ncbi.nlm.nih.gov/pubmed/35685818
http://dx.doi.org/10.1039/d1ra00581b
_version_ 1784713159005700096
author Abd-Rabboh, Hisham S. M.
El-Galil E. Amr, Abd
A. Elsayed, Elsayed
Sayed, Ahmed Y. A.
Kamel, Ayman H.
author_facet Abd-Rabboh, Hisham S. M.
El-Galil E. Amr, Abd
A. Elsayed, Elsayed
Sayed, Ahmed Y. A.
Kamel, Ayman H.
author_sort Abd-Rabboh, Hisham S. M.
collection PubMed
description Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized. A printed pholcodinium (PHL)(2+)/5-nitrobarbiturate (NB)(−) ion-association complex as a sensory material-based all-solid-state ion-selective electrode (ISE) on a chemically reduced graphene oxide (CRGO) solid-contact, and a printed all-solid-state Ag/AgCl reference electrode, has been combined on a hydrophobic paper substrate coated with fluorinated alkyl silane (CF(3)(CF(2))(7)CH(2)CH(2)SiCl(3), C(F)(10)). The sensors revealed a potentiometric slope of 28.7 ± 0.3 mV dec(−1) (R(2) = 0.9998) over a linear range starting from 2.0 × 10(−7) M to 1.0 × 10(−2) M and a detection limit of 0.04 μg mL(−1). The repeatability and stability of the pholcodine paper-based sensor was found to be 2.32%. The RSD% (n = 6) was found to be 2.67% when using five different paper-based sensors. The sensor revealed an excellent selectivity towards PHL over dextromethorphan, codeine, ephedrine, carbinoxamine, caffeine, ketamine, and K(+), Na(+) and Ca(2+) ions. It showed a good recovery (94–104%) for the determination of PHL in different artificial serum samples. The presented paper-based analytical device was successfully introduced for PHL determination in different pharmaceutical formulations (i.e. syrups and suspensions) containing pholcodine. The current work can be considered as a promising possible analytical tool to obtain cost-effective and disposable paper-based potentiometric sensing devices. These devices can be potentially manufacturable at large scales in pharmaceutical, clinical and forensic applications for opiate drug assessment.
format Online
Article
Text
id pubmed-9131362
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-91313622022-06-08 Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug) Abd-Rabboh, Hisham S. M. El-Galil E. Amr, Abd A. Elsayed, Elsayed Sayed, Ahmed Y. A. Kamel, Ayman H. RSC Adv Chemistry Robust, reliable and cost-effective paper-based analytical device for potentiometric pholcodine (opiate derivative drug) ion sensing has been prepared and characterized. A printed pholcodinium (PHL)(2+)/5-nitrobarbiturate (NB)(−) ion-association complex as a sensory material-based all-solid-state ion-selective electrode (ISE) on a chemically reduced graphene oxide (CRGO) solid-contact, and a printed all-solid-state Ag/AgCl reference electrode, has been combined on a hydrophobic paper substrate coated with fluorinated alkyl silane (CF(3)(CF(2))(7)CH(2)CH(2)SiCl(3), C(F)(10)). The sensors revealed a potentiometric slope of 28.7 ± 0.3 mV dec(−1) (R(2) = 0.9998) over a linear range starting from 2.0 × 10(−7) M to 1.0 × 10(−2) M and a detection limit of 0.04 μg mL(−1). The repeatability and stability of the pholcodine paper-based sensor was found to be 2.32%. The RSD% (n = 6) was found to be 2.67% when using five different paper-based sensors. The sensor revealed an excellent selectivity towards PHL over dextromethorphan, codeine, ephedrine, carbinoxamine, caffeine, ketamine, and K(+), Na(+) and Ca(2+) ions. It showed a good recovery (94–104%) for the determination of PHL in different artificial serum samples. The presented paper-based analytical device was successfully introduced for PHL determination in different pharmaceutical formulations (i.e. syrups and suspensions) containing pholcodine. The current work can be considered as a promising possible analytical tool to obtain cost-effective and disposable paper-based potentiometric sensing devices. These devices can be potentially manufacturable at large scales in pharmaceutical, clinical and forensic applications for opiate drug assessment. The Royal Society of Chemistry 2021-03-26 /pmc/articles/PMC9131362/ /pubmed/35685818 http://dx.doi.org/10.1039/d1ra00581b Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Abd-Rabboh, Hisham S. M.
El-Galil E. Amr, Abd
A. Elsayed, Elsayed
Sayed, Ahmed Y. A.
Kamel, Ayman H.
Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title_full Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title_fullStr Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title_full_unstemmed Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title_short Paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (CRGO) for trace level determination of pholcodine (opiate derivative drug)
title_sort paper-based potentiometric sensing devices modified with chemically reduced graphene oxide (crgo) for trace level determination of pholcodine (opiate derivative drug)
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9131362/
https://www.ncbi.nlm.nih.gov/pubmed/35685818
http://dx.doi.org/10.1039/d1ra00581b
work_keys_str_mv AT abdrabbohhishamsm paperbasedpotentiometricsensingdevicesmodifiedwithchemicallyreducedgrapheneoxidecrgofortraceleveldeterminationofpholcodineopiatederivativedrug
AT elgalileamrabd paperbasedpotentiometricsensingdevicesmodifiedwithchemicallyreducedgrapheneoxidecrgofortraceleveldeterminationofpholcodineopiatederivativedrug
AT aelsayedelsayed paperbasedpotentiometricsensingdevicesmodifiedwithchemicallyreducedgrapheneoxidecrgofortraceleveldeterminationofpholcodineopiatederivativedrug
AT sayedahmedya paperbasedpotentiometricsensingdevicesmodifiedwithchemicallyreducedgrapheneoxidecrgofortraceleveldeterminationofpholcodineopiatederivativedrug
AT kamelaymanh paperbasedpotentiometricsensingdevicesmodifiedwithchemicallyreducedgrapheneoxidecrgofortraceleveldeterminationofpholcodineopiatederivativedrug