Cargando…

Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model

Treatment of benign biliary strictures (BBS) using fully covered self-expandable metal stents (FCSEMS) has a high success rate, but recurrence can occur. Corticosteroids may be useful based on their anti-fibrotic and anti-inflammatory effects. We investigated the safety and efficacy of corticosteroi...

Descripción completa

Detalles Bibliográficos
Autores principales: Jang, Sung Ill, Fang, Sungsoon, Nahm, Ji Hae, Cho, Jae Hee, Do, Min Young, Lee, Su Yeon, Jeong, Seok, Lee, Don Haeng, Lee, Dong Ki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9132970/
https://www.ncbi.nlm.nih.gov/pubmed/35614115
http://dx.doi.org/10.1038/s41598-022-12957-0
_version_ 1784713495170777088
author Jang, Sung Ill
Fang, Sungsoon
Nahm, Ji Hae
Cho, Jae Hee
Do, Min Young
Lee, Su Yeon
Jeong, Seok
Lee, Don Haeng
Lee, Dong Ki
author_facet Jang, Sung Ill
Fang, Sungsoon
Nahm, Ji Hae
Cho, Jae Hee
Do, Min Young
Lee, Su Yeon
Jeong, Seok
Lee, Don Haeng
Lee, Dong Ki
author_sort Jang, Sung Ill
collection PubMed
description Treatment of benign biliary strictures (BBS) using fully covered self-expandable metal stents (FCSEMS) has a high success rate, but recurrence can occur. Corticosteroids may be useful based on their anti-fibrotic and anti-inflammatory effects. We investigated the safety and efficacy of corticosteroid-eluting FCSEMS in an animal model. BBSs were created by radiofrequency ablation in 12 mini-pigs. Four weeks later, FCSEMS coated with 0 mg (control), 15 mg (steroid 1 × group), or 30 mg (steroid 2 × group) triamcinolone were inserted endoscopically. The in vitro drug release assay revealed that the optimal stent had 15 mg of triamcinolone and a hydrophilic membrane. No transmural necrosis or perforation occurred in any animal. Fibrous wall thickness tended to decrease macroscopically and microscopically in a triamcinolone dose-dependent manner (control vs. steroid 2 × group: 773.1 vs. 468.5 µm, P = 0.037). Thickness also decreased over time in the steroid 2 × group (3 days vs. 4 weeks: 907.9 vs. 468.5 µm, P = 0.025). Blood parameters tended to improve after stent insertion. In a porcine BBS model, steroid-eluting FCSEMS showed potential as a safe and effective treatment modality to reduce fibrotic tissue. Studies are required to confirm their safety and efficacy in humans with refractory BBS.
format Online
Article
Text
id pubmed-9132970
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-91329702022-05-27 Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model Jang, Sung Ill Fang, Sungsoon Nahm, Ji Hae Cho, Jae Hee Do, Min Young Lee, Su Yeon Jeong, Seok Lee, Don Haeng Lee, Dong Ki Sci Rep Article Treatment of benign biliary strictures (BBS) using fully covered self-expandable metal stents (FCSEMS) has a high success rate, but recurrence can occur. Corticosteroids may be useful based on their anti-fibrotic and anti-inflammatory effects. We investigated the safety and efficacy of corticosteroid-eluting FCSEMS in an animal model. BBSs were created by radiofrequency ablation in 12 mini-pigs. Four weeks later, FCSEMS coated with 0 mg (control), 15 mg (steroid 1 × group), or 30 mg (steroid 2 × group) triamcinolone were inserted endoscopically. The in vitro drug release assay revealed that the optimal stent had 15 mg of triamcinolone and a hydrophilic membrane. No transmural necrosis or perforation occurred in any animal. Fibrous wall thickness tended to decrease macroscopically and microscopically in a triamcinolone dose-dependent manner (control vs. steroid 2 × group: 773.1 vs. 468.5 µm, P = 0.037). Thickness also decreased over time in the steroid 2 × group (3 days vs. 4 weeks: 907.9 vs. 468.5 µm, P = 0.025). Blood parameters tended to improve after stent insertion. In a porcine BBS model, steroid-eluting FCSEMS showed potential as a safe and effective treatment modality to reduce fibrotic tissue. Studies are required to confirm their safety and efficacy in humans with refractory BBS. Nature Publishing Group UK 2022-05-25 /pmc/articles/PMC9132970/ /pubmed/35614115 http://dx.doi.org/10.1038/s41598-022-12957-0 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Jang, Sung Ill
Fang, Sungsoon
Nahm, Ji Hae
Cho, Jae Hee
Do, Min Young
Lee, Su Yeon
Jeong, Seok
Lee, Don Haeng
Lee, Dong Ki
Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title_full Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title_fullStr Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title_full_unstemmed Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title_short Preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
title_sort preclinical evaluation of endoscopic placement of a steroid-eluting metal stent in an in vivo porcine benign biliary stricture model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9132970/
https://www.ncbi.nlm.nih.gov/pubmed/35614115
http://dx.doi.org/10.1038/s41598-022-12957-0
work_keys_str_mv AT jangsungill preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT fangsungsoon preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT nahmjihae preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT chojaehee preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT dominyoung preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT leesuyeon preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT jeongseok preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT leedonhaeng preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel
AT leedongki preclinicalevaluationofendoscopicplacementofasteroidelutingmetalstentinaninvivoporcinebenignbiliarystricturemodel