Cargando…

Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis

AIMS: The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadekar, Vilas, Watts, Arun T., Moulder, Elizabeth, Souroullas, Panayiotis, Hadland, Yvonne, Barron, Elizabeth, Muir, Ross, Sharma, Hemant K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9134831/
https://www.ncbi.nlm.nih.gov/pubmed/35491551
http://dx.doi.org/10.1302/2633-1462.35.BJO-2021-0179.R1
_version_ 1784713837786693632
author Sadekar, Vilas
Watts, Arun T.
Moulder, Elizabeth
Souroullas, Panayiotis
Hadland, Yvonne
Barron, Elizabeth
Muir, Ross
Sharma, Hemant K.
author_facet Sadekar, Vilas
Watts, Arun T.
Moulder, Elizabeth
Souroullas, Panayiotis
Hadland, Yvonne
Barron, Elizabeth
Muir, Ross
Sharma, Hemant K.
author_sort Sadekar, Vilas
collection PubMed
description AIMS: The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. METHODS: We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture. RESULTS: There were 244 frames (230 patients) included in the analyses, of which 90 were Ilizarov type frames and 154 were hexapods. There were 149 frames which underwent single-stage reloading and 95 frames which underwent a two-stage reloading protocol. Mechanical failure occurred after frame removal in 13 frames (5%), which suffered refracture. There were no cases of change in alignment. There was no difference between refracture patients who underwent single-stage or two-stage reloading protocols (p = 0.772). In all, 14 patients had failure prevented through identification with the reloading protocol. CONCLUSION: Our reloading protocol is a simple and effective way to confirm the timing of frame removal and minimize the rate of mechanical failure. Similar failure rates occurred between patients undergoing single-stage and two-stage reloading protocols. If the surgeon is confident with clinical and radiological assessment, it may be possible to progress directly to stage two and decrease frame time and patient morbidity. Cite this article: Bone Jt Open 2022;3(5):359–366.
format Online
Article
Text
id pubmed-9134831
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-91348312022-06-09 Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis Sadekar, Vilas Watts, Arun T. Moulder, Elizabeth Souroullas, Panayiotis Hadland, Yvonne Barron, Elizabeth Muir, Ross Sharma, Hemant K. Bone Jt Open General Orthopaedics AIMS: The timing of when to remove a circular frame is crucial; early removal results in refracture or deformity, while late removal increases the patient morbidity and delay in return to work. This study was designed to assess the effectiveness of a staged reloading protocol. We report the incidence of mechanical failure following both single-stage and two stage reloading protocols and analyze the associated risk factors. METHODS: We identified consecutive patients from our departmental database. Both trauma and elective cases were included, of all ages, frame types, and pathologies who underwent circular frame treatment. Our protocol is either a single-stage or two-stage process implemented by defunctioning the frame, in order to progressively increase the weightbearing load through the bone, and promote full loading prior to frame removal. Before progression, through the process we monitor patients for any increase in pain and assess radiographs for deformity or refracture. RESULTS: There were 244 frames (230 patients) included in the analyses, of which 90 were Ilizarov type frames and 154 were hexapods. There were 149 frames which underwent single-stage reloading and 95 frames which underwent a two-stage reloading protocol. Mechanical failure occurred after frame removal in 13 frames (5%), which suffered refracture. There were no cases of change in alignment. There was no difference between refracture patients who underwent single-stage or two-stage reloading protocols (p = 0.772). In all, 14 patients had failure prevented through identification with the reloading protocol. CONCLUSION: Our reloading protocol is a simple and effective way to confirm the timing of frame removal and minimize the rate of mechanical failure. Similar failure rates occurred between patients undergoing single-stage and two-stage reloading protocols. If the surgeon is confident with clinical and radiological assessment, it may be possible to progress directly to stage two and decrease frame time and patient morbidity. Cite this article: Bone Jt Open 2022;3(5):359–366. The British Editorial Society of Bone & Joint Surgery 2022-04-30 /pmc/articles/PMC9134831/ /pubmed/35491551 http://dx.doi.org/10.1302/2633-1462.35.BJO-2021-0179.R1 Text en © 2022 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle General Orthopaedics
Sadekar, Vilas
Watts, Arun T.
Moulder, Elizabeth
Souroullas, Panayiotis
Hadland, Yvonne
Barron, Elizabeth
Muir, Ross
Sharma, Hemant K.
Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title_full Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title_fullStr Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title_full_unstemmed Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title_short Is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
title_sort is a staged reloading protocol effective to time the removal of circular frames?: a retrospective analysis
topic General Orthopaedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9134831/
https://www.ncbi.nlm.nih.gov/pubmed/35491551
http://dx.doi.org/10.1302/2633-1462.35.BJO-2021-0179.R1
work_keys_str_mv AT sadekarvilas isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT wattsarunt isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT moulderelizabeth isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT souroullaspanayiotis isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT hadlandyvonne isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT barronelizabeth isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT muirross isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis
AT sharmahemantk isastagedreloadingprotocoleffectivetotimetheremovalofcircularframesaretrospectiveanalysis