Cargando…

Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle

OBJECTIVE: To investigate the effect of different body mass indexes (BMIs) on patients' puncture pain, puncture success rate, and image quality in coronary angiography (CAG) performed with an intravenous indwelling needle, and to provide a basis for selecting the appropriate intravenous indwell...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Jiani, Chen, Xiaoyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9135555/
https://www.ncbi.nlm.nih.gov/pubmed/35646398
http://dx.doi.org/10.1155/2022/4105875
_version_ 1784713985347551232
author Ding, Jiani
Chen, Xiaoyu
author_facet Ding, Jiani
Chen, Xiaoyu
author_sort Ding, Jiani
collection PubMed
description OBJECTIVE: To investigate the effect of different body mass indexes (BMIs) on patients' puncture pain, puncture success rate, and image quality in coronary angiography (CAG) performed with an intravenous indwelling needle, and to provide a basis for selecting the appropriate intravenous indwelling needle for CAG in patients with different BMIs in an outpatient clinic. METHOD: In this study, 300 patients undergoing CTA at the department of radiology in the First Affiliated Hospital of Wenzhou Medical University from January to May 2021 were divided into group 1 (BMI 1 ≤ 18.5), group 2 (18.5 < BMI ≤ 24), and group 3 (BMI > 24) according to their BMI, with 100 cases in each group, and a 20 G intravenous indwelling needle was used in each group. The age, sex, height, and weight of each patient were recorded, and the primary puncture success rate, contrast leakage rate, injection success rate, pain perception, and subjective ratings of image quality and objective indicators were compared in patients with different BMI values. RESULTS: There was no statistically significant difference between the age, gender, and heart rate of the patients in the three groups (P > 0.05). There was no statistically significant difference between the primary puncture success rate, injection success rate, and contrast leakage rate of the three groups of patients (P > 0.05). The pain scores of group 3 during contrast injection were significantly higher than those of the remaining two groups (P < 0.05), while the differences between the pain scores of group 2 and group 1 during contrast injection were not statistically significant (P > 0.05); the comparison of the pain scores of the three groups during puncture and during retention was not statistically significant (P > 0.05). The differences between the subjective ratings of image quality and the objective indicators of the three groups were not statistically significant (P > 0.05). CONCLUSION: The 20 G indwelling needle can basically meet the coronary angiography examination of patients with different body mass indexes, but patients with a BMI greater than 24 are recommended to use a larger diameter indwelling needle to reduce contrast leakage as well as to reduce patient pain and improve patient comfort.
format Online
Article
Text
id pubmed-9135555
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91355552022-05-27 Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle Ding, Jiani Chen, Xiaoyu Emerg Med Int Research Article OBJECTIVE: To investigate the effect of different body mass indexes (BMIs) on patients' puncture pain, puncture success rate, and image quality in coronary angiography (CAG) performed with an intravenous indwelling needle, and to provide a basis for selecting the appropriate intravenous indwelling needle for CAG in patients with different BMIs in an outpatient clinic. METHOD: In this study, 300 patients undergoing CTA at the department of radiology in the First Affiliated Hospital of Wenzhou Medical University from January to May 2021 were divided into group 1 (BMI 1 ≤ 18.5), group 2 (18.5 < BMI ≤ 24), and group 3 (BMI > 24) according to their BMI, with 100 cases in each group, and a 20 G intravenous indwelling needle was used in each group. The age, sex, height, and weight of each patient were recorded, and the primary puncture success rate, contrast leakage rate, injection success rate, pain perception, and subjective ratings of image quality and objective indicators were compared in patients with different BMI values. RESULTS: There was no statistically significant difference between the age, gender, and heart rate of the patients in the three groups (P > 0.05). There was no statistically significant difference between the primary puncture success rate, injection success rate, and contrast leakage rate of the three groups of patients (P > 0.05). The pain scores of group 3 during contrast injection were significantly higher than those of the remaining two groups (P < 0.05), while the differences between the pain scores of group 2 and group 1 during contrast injection were not statistically significant (P > 0.05); the comparison of the pain scores of the three groups during puncture and during retention was not statistically significant (P > 0.05). The differences between the subjective ratings of image quality and the objective indicators of the three groups were not statistically significant (P > 0.05). CONCLUSION: The 20 G indwelling needle can basically meet the coronary angiography examination of patients with different body mass indexes, but patients with a BMI greater than 24 are recommended to use a larger diameter indwelling needle to reduce contrast leakage as well as to reduce patient pain and improve patient comfort. Hindawi 2022-05-19 /pmc/articles/PMC9135555/ /pubmed/35646398 http://dx.doi.org/10.1155/2022/4105875 Text en Copyright © 2022 Jiani Ding and Xiaoyu Chen. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ding, Jiani
Chen, Xiaoyu
Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title_full Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title_fullStr Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title_full_unstemmed Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title_short Study on the Relationship between Different Body Mass Indexes and Puncture Pain and Image Quality in Patients Undergoing Coronary Angiography with Intravenous Indwelling Needle
title_sort study on the relationship between different body mass indexes and puncture pain and image quality in patients undergoing coronary angiography with intravenous indwelling needle
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9135555/
https://www.ncbi.nlm.nih.gov/pubmed/35646398
http://dx.doi.org/10.1155/2022/4105875
work_keys_str_mv AT dingjiani studyontherelationshipbetweendifferentbodymassindexesandpuncturepainandimagequalityinpatientsundergoingcoronaryangiographywithintravenousindwellingneedle
AT chenxiaoyu studyontherelationshipbetweendifferentbodymassindexesandpuncturepainandimagequalityinpatientsundergoingcoronaryangiographywithintravenousindwellingneedle