Cargando…

Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows

SIMPLE SUMMARY: Methane that is breathed out and eructed from ruminants is a potent greenhouse gas that contributes to climate change. Although metabolic chambers are the “gold standard” for measuring methane from livestock, their application in production farms is very limited. There is a need to d...

Descripción completa

Detalles Bibliográficos
Autores principales: Boré, Raphaël, Bruder, Thiphaine, El Jabri, Mohammed, March, Margaret, Hargreaves, Paul R., Rouillé, Benoît, Dewhurst, Richard J., Chagunda, Mizeck G. G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9138097/
https://www.ncbi.nlm.nih.gov/pubmed/35625141
http://dx.doi.org/10.3390/ani12101295
_version_ 1784714541638090752
author Boré, Raphaël
Bruder, Thiphaine
El Jabri, Mohammed
March, Margaret
Hargreaves, Paul R.
Rouillé, Benoît
Dewhurst, Richard J.
Chagunda, Mizeck G. G.
author_facet Boré, Raphaël
Bruder, Thiphaine
El Jabri, Mohammed
March, Margaret
Hargreaves, Paul R.
Rouillé, Benoît
Dewhurst, Richard J.
Chagunda, Mizeck G. G.
author_sort Boré, Raphaël
collection PubMed
description SIMPLE SUMMARY: Methane that is breathed out and eructed from ruminants is a potent greenhouse gas that contributes to climate change. Although metabolic chambers are the “gold standard” for measuring methane from livestock, their application in production farms is very limited. There is a need to develop proxy methods that can be applied in such production environments. The proprietary Laser Methane Detector (LMD) has been trialed for the previous decade and has demonstrated its usefulness as a non-invasive and portable instrument to determine methane output from ruminants. In validating the reliability and stability of the data generated by the LMD, the current study gives answers to some very practical assumptions used in the use of the LMD and enhances the confidence in its use in ruminants. ABSTRACT: The laser methane detector (LMD), is a proprietary hand-held open path laser measuring device. Its measurements are based on infrared absorption spectroscopy using a semiconductor laser as a collimated excitation source. In the current study, LMD measurements were carried out in two experiments using 20 and 71 lactating dairy cows in Spain and Scotland, respectively. The study aimed at testing four assumptions that may impact on the reliability and repeatability of the LMD measurements of ruminants. The study has verified that there is no difference in enteric methane measurements taken from a distance of 3 m than from those taken at a distance of 2 m; there was no effect to the measurements when the measurement angle was adjusted from 90° to 45°; that the presence of an adjacent animal had no effect on the methane measurements; and that measurements lasting up to 240 s are more precise than those taken for a shorter duration. The results indicate that angle, proximity to other animals, and distance had no effects and that measurements need to last a minimum of 240 s to maintain precision.
format Online
Article
Text
id pubmed-9138097
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91380972022-05-28 Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows Boré, Raphaël Bruder, Thiphaine El Jabri, Mohammed March, Margaret Hargreaves, Paul R. Rouillé, Benoît Dewhurst, Richard J. Chagunda, Mizeck G. G. Animals (Basel) Article SIMPLE SUMMARY: Methane that is breathed out and eructed from ruminants is a potent greenhouse gas that contributes to climate change. Although metabolic chambers are the “gold standard” for measuring methane from livestock, their application in production farms is very limited. There is a need to develop proxy methods that can be applied in such production environments. The proprietary Laser Methane Detector (LMD) has been trialed for the previous decade and has demonstrated its usefulness as a non-invasive and portable instrument to determine methane output from ruminants. In validating the reliability and stability of the data generated by the LMD, the current study gives answers to some very practical assumptions used in the use of the LMD and enhances the confidence in its use in ruminants. ABSTRACT: The laser methane detector (LMD), is a proprietary hand-held open path laser measuring device. Its measurements are based on infrared absorption spectroscopy using a semiconductor laser as a collimated excitation source. In the current study, LMD measurements were carried out in two experiments using 20 and 71 lactating dairy cows in Spain and Scotland, respectively. The study aimed at testing four assumptions that may impact on the reliability and repeatability of the LMD measurements of ruminants. The study has verified that there is no difference in enteric methane measurements taken from a distance of 3 m than from those taken at a distance of 2 m; there was no effect to the measurements when the measurement angle was adjusted from 90° to 45°; that the presence of an adjacent animal had no effect on the methane measurements; and that measurements lasting up to 240 s are more precise than those taken for a shorter duration. The results indicate that angle, proximity to other animals, and distance had no effects and that measurements need to last a minimum of 240 s to maintain precision. MDPI 2022-05-18 /pmc/articles/PMC9138097/ /pubmed/35625141 http://dx.doi.org/10.3390/ani12101295 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Boré, Raphaël
Bruder, Thiphaine
El Jabri, Mohammed
March, Margaret
Hargreaves, Paul R.
Rouillé, Benoît
Dewhurst, Richard J.
Chagunda, Mizeck G. G.
Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title_full Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title_fullStr Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title_full_unstemmed Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title_short Measurement Duration but Not Distance, Angle, and Neighbour-Proximity Affects Precision in Enteric Methane Emissions when Using the Laser Methane Detector Technique in Lactating Dairy Cows
title_sort measurement duration but not distance, angle, and neighbour-proximity affects precision in enteric methane emissions when using the laser methane detector technique in lactating dairy cows
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9138097/
https://www.ncbi.nlm.nih.gov/pubmed/35625141
http://dx.doi.org/10.3390/ani12101295
work_keys_str_mv AT boreraphael measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT bruderthiphaine measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT eljabrimohammed measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT marchmargaret measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT hargreavespaulr measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT rouillebenoit measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT dewhurstrichardj measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows
AT chagundamizeckgg measurementdurationbutnotdistanceangleandneighbourproximityaffectsprecisioninentericmethaneemissionswhenusingthelasermethanedetectortechniqueinlactatingdairycows