Cargando…

Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes

Objective Despite the decline in the incidence of rheumatic heart disease in developed countries, the disease still remains endemic among individuals of low socioeconomic status. The aim of the study is to assess immediate and one-year outcomes of balloon mitral valvotomy using the double-lumen Accu...

Descripción completa

Detalles Bibliográficos
Autores principales: Khanal, Suraj, Yamasandi Siddegowda, Shrimanth, Kumar, Basant
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9138188/
https://www.ncbi.nlm.nih.gov/pubmed/35651439
http://dx.doi.org/10.7759/cureus.24610
_version_ 1784714562739634176
author Khanal, Suraj
Yamasandi Siddegowda, Shrimanth
Kumar, Basant
author_facet Khanal, Suraj
Yamasandi Siddegowda, Shrimanth
Kumar, Basant
author_sort Khanal, Suraj
collection PubMed
description Objective Despite the decline in the incidence of rheumatic heart disease in developed countries, the disease still remains endemic among individuals of low socioeconomic status. The aim of the study is to assess immediate and one-year outcomes of balloon mitral valvotomy using the double-lumen Accura balloon (Vascular Innovations Co., Nonthaburi, Thailand) in patients with mitral valve stenosis. Methods This was a single-centre, observational, investigator-initiated retrospective study. All consecutive patients undergoing balloon mitral valvotomy with the Accura balloon between January 2015 and June 2020 were included. The primary endpoint was procedural success defined as an increase in mitral valve area (MVA) ≥50% from basal valve area or final valve area of ≥1.5 cm(2), in the absence of mitral regurgitation grade >2. Clinical, echocardiographic, and haemodynamic parameters were assessed at the one-year follow-up. Results A total of 62 patients underwent balloon mitral valvotomy. The mean age was 34.9 ± 8.0 years, and 54 (87.1%) patients were female. Mean Wilkins' echo score was 7.5 ± 0.5. Procedural success was achieved in 59 (96.7%) patients. Mean MVA increased from 0.75 ± 0.14 cm(2) to 1.64 ± 0.21 cm(2), and mean mitral valve gradient decreased from 24.9 ± 5.5 mmHg to 7.30 ± 1.40 mmHg. Atrial fibrillation, mitral valve replacement, and moderate to severe mitral regurgitation occurred in 36 (59.0%), two (3.3%), and two (3.3%) patients, respectively. No death, cerebrovascular accidents, restenosis, or redo procedures occurred. Conclusion Balloon mitral valvotomy using the double-lumen Accura balloon is safe in patients with mitral valve stenosis.
format Online
Article
Text
id pubmed-9138188
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-91381882022-05-31 Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes Khanal, Suraj Yamasandi Siddegowda, Shrimanth Kumar, Basant Cureus Cardiology Objective Despite the decline in the incidence of rheumatic heart disease in developed countries, the disease still remains endemic among individuals of low socioeconomic status. The aim of the study is to assess immediate and one-year outcomes of balloon mitral valvotomy using the double-lumen Accura balloon (Vascular Innovations Co., Nonthaburi, Thailand) in patients with mitral valve stenosis. Methods This was a single-centre, observational, investigator-initiated retrospective study. All consecutive patients undergoing balloon mitral valvotomy with the Accura balloon between January 2015 and June 2020 were included. The primary endpoint was procedural success defined as an increase in mitral valve area (MVA) ≥50% from basal valve area or final valve area of ≥1.5 cm(2), in the absence of mitral regurgitation grade >2. Clinical, echocardiographic, and haemodynamic parameters were assessed at the one-year follow-up. Results A total of 62 patients underwent balloon mitral valvotomy. The mean age was 34.9 ± 8.0 years, and 54 (87.1%) patients were female. Mean Wilkins' echo score was 7.5 ± 0.5. Procedural success was achieved in 59 (96.7%) patients. Mean MVA increased from 0.75 ± 0.14 cm(2) to 1.64 ± 0.21 cm(2), and mean mitral valve gradient decreased from 24.9 ± 5.5 mmHg to 7.30 ± 1.40 mmHg. Atrial fibrillation, mitral valve replacement, and moderate to severe mitral regurgitation occurred in 36 (59.0%), two (3.3%), and two (3.3%) patients, respectively. No death, cerebrovascular accidents, restenosis, or redo procedures occurred. Conclusion Balloon mitral valvotomy using the double-lumen Accura balloon is safe in patients with mitral valve stenosis. Cureus 2022-04-29 /pmc/articles/PMC9138188/ /pubmed/35651439 http://dx.doi.org/10.7759/cureus.24610 Text en Copyright © 2022, Khanal et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiology
Khanal, Suraj
Yamasandi Siddegowda, Shrimanth
Kumar, Basant
Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title_full Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title_fullStr Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title_full_unstemmed Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title_short Balloon Mitral Valvotomy With the Accura Double-Lumen Balloon Catheter: Immediate and One-Year Clinical Outcomes
title_sort balloon mitral valvotomy with the accura double-lumen balloon catheter: immediate and one-year clinical outcomes
topic Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9138188/
https://www.ncbi.nlm.nih.gov/pubmed/35651439
http://dx.doi.org/10.7759/cureus.24610
work_keys_str_mv AT khanalsuraj balloonmitralvalvotomywiththeaccuradoublelumenballooncatheterimmediateandoneyearclinicaloutcomes
AT yamasandisiddegowdashrimanth balloonmitralvalvotomywiththeaccuradoublelumenballooncatheterimmediateandoneyearclinicaloutcomes
AT kumarbasant balloonmitralvalvotomywiththeaccuradoublelumenballooncatheterimmediateandoneyearclinicaloutcomes