Cargando…
Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function
Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139480/ https://www.ncbi.nlm.nih.gov/pubmed/35621541 http://dx.doi.org/10.3390/dj10050088 |
_version_ | 1784714868895514624 |
---|---|
author | D'haese, Jan Matthys, Carine Sahak, Hamed Besseler, Jos De Bruyn, Hugo |
author_facet | D'haese, Jan Matthys, Carine Sahak, Hamed Besseler, Jos De Bruyn, Hugo |
author_sort | D'haese, Jan |
collection | PubMed |
description | Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator(®) Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used. |
format | Online Article Text |
id | pubmed-9139480 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91394802022-05-28 Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function D'haese, Jan Matthys, Carine Sahak, Hamed Besseler, Jos De Bruyn, Hugo Dent J (Basel) Article Denture wearers often complain about jeopardized function and reduced quality of life due to lack of prosthesis’ retention. Implant-retained mandibular overdentures, on two non-connected implants (2IOD) are well-proven solutions to overcome these issues. We prospectively assessed 69 patients and scrutinized clinical records until at least seven years of function. Thirty-six were retained on Locator(®) Abutments (LA) and thirty-tree on Ball Abutments (BA). Both systems were compared regarding the type, amount, and total cost of required maintenance. One implant was lost, yielding 98.7% survival after seven years. In total, 438 technical issues occurred: 121 (27.35%) in BA and 317 (72.4%) in LA. Out of these, 343 events (78%) were solved chairside: 191 (43.6%) were replacements of retention caps, 113 (25.8%) were minor acrylic repairs, 26 (5.9%) pressure ulcers had to be relieved, and 13 (3%) were related to abutments. LA required 179 insert replacements compared to 12 in the BA group. The overall initial treatment cost was EUR 3850 (base year of the analysis: 2003). The average total maintenance cost in relation to the initial cost for the LA and BA groups was 19.11 (range 0–82.24%) and 18.91% (range 0–113.26%) respectively (p = 0.540). Conclusions: The seven-year maintenance costs for a 2IOD is acceptable when the patient is regularly checked and professionally maintained. Most events are easily solvable chairside, but a few patients required more expensive interventions, regardless of the type of attachment used. MDPI 2022-05-16 /pmc/articles/PMC9139480/ /pubmed/35621541 http://dx.doi.org/10.3390/dj10050088 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article D'haese, Jan Matthys, Carine Sahak, Hamed Besseler, Jos De Bruyn, Hugo Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title | Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title_full | Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title_fullStr | Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title_full_unstemmed | Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title_short | Implant-Retained Mandibular Overdentures: Patient-Related Outcome Measurements after Seven Years of Function |
title_sort | implant-retained mandibular overdentures: patient-related outcome measurements after seven years of function |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139480/ https://www.ncbi.nlm.nih.gov/pubmed/35621541 http://dx.doi.org/10.3390/dj10050088 |
work_keys_str_mv | AT dhaesejan implantretainedmandibularoverdenturespatientrelatedoutcomemeasurementsaftersevenyearsoffunction AT matthyscarine implantretainedmandibularoverdenturespatientrelatedoutcomemeasurementsaftersevenyearsoffunction AT sahakhamed implantretainedmandibularoverdenturespatientrelatedoutcomemeasurementsaftersevenyearsoffunction AT besselerjos implantretainedmandibularoverdenturespatientrelatedoutcomemeasurementsaftersevenyearsoffunction AT debruynhugo implantretainedmandibularoverdenturespatientrelatedoutcomemeasurementsaftersevenyearsoffunction |