Cargando…
A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions †
Flow injection analysis–tandem mass spectrometry (FIA-TMS) has been applied in a first-tier test of newborn screening (NBS). Although isovalerylcarnitine (i-C5), which is a diagnostic indicator of isovaleric acidemia (IVA), is isobaric with pivaloylcarnitine (p-C5), 2-methylbutyrylcarnitine, and n-v...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139860/ https://www.ncbi.nlm.nih.gov/pubmed/35626871 http://dx.doi.org/10.3390/children9050694 |
_version_ | 1784714958967144448 |
---|---|
author | Hattori, Takanari Notsu, Yoshitomo Tanaka, Misa Matsui, Miki Iida, Tetsuo Watanabe, Jun Osawa, Yoshimitsu Yamaguchi, Seiji Yano, Shozo Taketani, Takeshi Kobayashi, Hironori |
author_facet | Hattori, Takanari Notsu, Yoshitomo Tanaka, Misa Matsui, Miki Iida, Tetsuo Watanabe, Jun Osawa, Yoshimitsu Yamaguchi, Seiji Yano, Shozo Taketani, Takeshi Kobayashi, Hironori |
author_sort | Hattori, Takanari |
collection | PubMed |
description | Flow injection analysis–tandem mass spectrometry (FIA-TMS) has been applied in a first-tier test of newborn screening (NBS). Although isovalerylcarnitine (i-C5), which is a diagnostic indicator of isovaleric acidemia (IVA), is isobaric with pivaloylcarnitine (p-C5), 2-methylbutyrylcarnitine, and n-valerylcarnitine, these isomers cannot be distinguished by the FIA-TMS. There are many reports of false positives derived from p-C5 due to the use of pivalate-conjugated antibiotics. In this study, we developed a new FIA-TMS method to distinguish i-C5 and p-C5. We found that the intensity ratio of product ions for i-C5 and p-C5 was different in a certain range even under the same analytical conditions. The product ions with the most distinct differences in ionic intensity between the isomers and the collision energies that produce them were determined to be m/z 246.2 > 187.1 and −15 V, respectively. In addition to the quantification ion, a reference ion was defined, and the similarity of the i-C5 and p-C5 reference ion ratios (i-C5 score and p-C5 score, respectively) were used to estimate which isomer (i-C5 and p-C5) was responsible for elevated C5 acylcarnitine in dried blood spots (DBSs). As a result of analyses of 11 DBS samples derived from pivalate-conjugated antibiotics and four DBS samples from IVA patients using our method, it was found that our method was able to correctly determine the type of C5-acylcarnitine (i-C5 or p-C5) in the DBS samples. Implementation of this new FIA-TMS method into the current NBS protocol will allow for a reduction in false positives in IVA. |
format | Online Article Text |
id | pubmed-9139860 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91398602022-05-28 A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † Hattori, Takanari Notsu, Yoshitomo Tanaka, Misa Matsui, Miki Iida, Tetsuo Watanabe, Jun Osawa, Yoshimitsu Yamaguchi, Seiji Yano, Shozo Taketani, Takeshi Kobayashi, Hironori Children (Basel) Article Flow injection analysis–tandem mass spectrometry (FIA-TMS) has been applied in a first-tier test of newborn screening (NBS). Although isovalerylcarnitine (i-C5), which is a diagnostic indicator of isovaleric acidemia (IVA), is isobaric with pivaloylcarnitine (p-C5), 2-methylbutyrylcarnitine, and n-valerylcarnitine, these isomers cannot be distinguished by the FIA-TMS. There are many reports of false positives derived from p-C5 due to the use of pivalate-conjugated antibiotics. In this study, we developed a new FIA-TMS method to distinguish i-C5 and p-C5. We found that the intensity ratio of product ions for i-C5 and p-C5 was different in a certain range even under the same analytical conditions. The product ions with the most distinct differences in ionic intensity between the isomers and the collision energies that produce them were determined to be m/z 246.2 > 187.1 and −15 V, respectively. In addition to the quantification ion, a reference ion was defined, and the similarity of the i-C5 and p-C5 reference ion ratios (i-C5 score and p-C5 score, respectively) were used to estimate which isomer (i-C5 and p-C5) was responsible for elevated C5 acylcarnitine in dried blood spots (DBSs). As a result of analyses of 11 DBS samples derived from pivalate-conjugated antibiotics and four DBS samples from IVA patients using our method, it was found that our method was able to correctly determine the type of C5-acylcarnitine (i-C5 or p-C5) in the DBS samples. Implementation of this new FIA-TMS method into the current NBS protocol will allow for a reduction in false positives in IVA. MDPI 2022-05-10 /pmc/articles/PMC9139860/ /pubmed/35626871 http://dx.doi.org/10.3390/children9050694 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hattori, Takanari Notsu, Yoshitomo Tanaka, Misa Matsui, Miki Iida, Tetsuo Watanabe, Jun Osawa, Yoshimitsu Yamaguchi, Seiji Yano, Shozo Taketani, Takeshi Kobayashi, Hironori A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title | A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title_full | A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title_fullStr | A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title_full_unstemmed | A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title_short | A Simple Flow Injection Analysis–Tandem Mass Spectrometry Method to Reduce False Positives of C5-Acylcarnitines Due to Pivaloylcarnitine Using Reference Ions † |
title_sort | simple flow injection analysis–tandem mass spectrometry method to reduce false positives of c5-acylcarnitines due to pivaloylcarnitine using reference ions † |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9139860/ https://www.ncbi.nlm.nih.gov/pubmed/35626871 http://dx.doi.org/10.3390/children9050694 |
work_keys_str_mv | AT hattoritakanari asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT notsuyoshitomo asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT tanakamisa asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT matsuimiki asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT iidatetsuo asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT watanabejun asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT osawayoshimitsu asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT yamaguchiseiji asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT yanoshozo asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT taketanitakeshi asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT kobayashihironori asimpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT hattoritakanari simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT notsuyoshitomo simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT tanakamisa simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT matsuimiki simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT iidatetsuo simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT watanabejun simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT osawayoshimitsu simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT yamaguchiseiji simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT yanoshozo simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT taketanitakeshi simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions AT kobayashihironori simpleflowinjectionanalysistandemmassspectrometrymethodtoreducefalsepositivesofc5acylcarnitinesduetopivaloylcarnitineusingreferenceions |