Cargando…

Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years

Adjuvanted vaccines are administered through intramuscular injection. To perform appropriate injection using an appropriate needle in different age groups or different daily living activities, we investigated the depth from the skin surface to muscle fascia and bone in the deltoid muscle area in 156...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakayama, Tetsuo, Sekino, Hisakuni, Aihara, Hirokazu, Kino, Minoru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9140583/
https://www.ncbi.nlm.nih.gov/pubmed/35627937
http://dx.doi.org/10.3390/healthcare10050800
_version_ 1784715133334847488
author Nakayama, Tetsuo
Sekino, Hisakuni
Aihara, Hirokazu
Kino, Minoru
author_facet Nakayama, Tetsuo
Sekino, Hisakuni
Aihara, Hirokazu
Kino, Minoru
author_sort Nakayama, Tetsuo
collection PubMed
description Adjuvanted vaccines are administered through intramuscular injection. To perform appropriate injection using an appropriate needle in different age groups or different daily living activities, we investigated the depth from the skin surface to muscle fascia and bone in the deltoid muscle area in 156 elderly aged ≥ 50 years by ultrasonic echography. Subjects consisted of 50 healthy elderly aged 50–64 years, 50 subjects aged 65–74 years, and 56 subjects aged ≥ 75 years (20 outpatients, 18 who needed nursing care, and 18 bedridden in a nursing home). The mean depth ± 1.0 SD from the skin surface to muscle fascia was 7.52 ± 2.13 mm for subjects aged ≥ 75 years, being shorter than 9.16 ± 3.02 mm in those aged 50–64years (p < 0.01). The depth from the skin surface to bone was 22.54 ± 3.85 mm for subjects aged ≥ 75 years and 25.41 ± 4.24 mm for those aged 65–74 years, significantly shorter than those aged 50–64 years (p < 0.01), depending on the reduced muscle volume. The subcutaneous volume length was greater in females (8.29 ± 2.63 mm) than in males (5.62 ± 2.80 mm) aged 50–64 years (p < 0.01). A similar result was obtained in those aged 65–74 years, but there was no difference in the muscle volume length. Our study found that a five-eighths of an inch (16 mm) needle was an appropriate length for average-sized elderly aged ≥ 50 years, but it should be longer for those with large body sizes.
format Online
Article
Text
id pubmed-9140583
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91405832022-05-28 Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years Nakayama, Tetsuo Sekino, Hisakuni Aihara, Hirokazu Kino, Minoru Healthcare (Basel) Article Adjuvanted vaccines are administered through intramuscular injection. To perform appropriate injection using an appropriate needle in different age groups or different daily living activities, we investigated the depth from the skin surface to muscle fascia and bone in the deltoid muscle area in 156 elderly aged ≥ 50 years by ultrasonic echography. Subjects consisted of 50 healthy elderly aged 50–64 years, 50 subjects aged 65–74 years, and 56 subjects aged ≥ 75 years (20 outpatients, 18 who needed nursing care, and 18 bedridden in a nursing home). The mean depth ± 1.0 SD from the skin surface to muscle fascia was 7.52 ± 2.13 mm for subjects aged ≥ 75 years, being shorter than 9.16 ± 3.02 mm in those aged 50–64years (p < 0.01). The depth from the skin surface to bone was 22.54 ± 3.85 mm for subjects aged ≥ 75 years and 25.41 ± 4.24 mm for those aged 65–74 years, significantly shorter than those aged 50–64 years (p < 0.01), depending on the reduced muscle volume. The subcutaneous volume length was greater in females (8.29 ± 2.63 mm) than in males (5.62 ± 2.80 mm) aged 50–64 years (p < 0.01). A similar result was obtained in those aged 65–74 years, but there was no difference in the muscle volume length. Our study found that a five-eighths of an inch (16 mm) needle was an appropriate length for average-sized elderly aged ≥ 50 years, but it should be longer for those with large body sizes. MDPI 2022-04-25 /pmc/articles/PMC9140583/ /pubmed/35627937 http://dx.doi.org/10.3390/healthcare10050800 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nakayama, Tetsuo
Sekino, Hisakuni
Aihara, Hirokazu
Kino, Minoru
Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title_full Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title_fullStr Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title_full_unstemmed Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title_short Appropriate Needle Length Determined by Ultrasonic Echography for Intramuscular Injection in Japanese Elderly over 50 Years
title_sort appropriate needle length determined by ultrasonic echography for intramuscular injection in japanese elderly over 50 years
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9140583/
https://www.ncbi.nlm.nih.gov/pubmed/35627937
http://dx.doi.org/10.3390/healthcare10050800
work_keys_str_mv AT nakayamatetsuo appropriateneedlelengthdeterminedbyultrasonicechographyforintramuscularinjectioninjapaneseelderlyover50years
AT sekinohisakuni appropriateneedlelengthdeterminedbyultrasonicechographyforintramuscularinjectioninjapaneseelderlyover50years
AT aiharahirokazu appropriateneedlelengthdeterminedbyultrasonicechographyforintramuscularinjectioninjapaneseelderlyover50years
AT kinominoru appropriateneedlelengthdeterminedbyultrasonicechographyforintramuscularinjectioninjapaneseelderlyover50years