Cargando…

Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study

(1) Background: The purpose of this prospective study was to determine the changes in primary hemodynamic parameters and oxygen saturation in systemically healthy patients during the surgical procedure involving crown lengthening. (2) Methods: A total of 44 patients who required a crown-lengthening...

Descripción completa

Detalles Bibliográficos
Autores principales: Alqahtani, Abdullah Saad, Sharanesha, Rajashekhara Bhari, Gufran, Khalid, Alqhtani, Nasser Raqe, Abushanan, Alwaleed, Alasqah, Mohammed, Alsakr, Abdulaziz Mohammad, Alkharaan, Hassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9141731/
https://www.ncbi.nlm.nih.gov/pubmed/35628056
http://dx.doi.org/10.3390/healthcare10050919
_version_ 1784715414957195264
author Alqahtani, Abdullah Saad
Sharanesha, Rajashekhara Bhari
Gufran, Khalid
Alqhtani, Nasser Raqe
Abushanan, Alwaleed
Alasqah, Mohammed
Alsakr, Abdulaziz Mohammad
Alkharaan, Hassan
author_facet Alqahtani, Abdullah Saad
Sharanesha, Rajashekhara Bhari
Gufran, Khalid
Alqhtani, Nasser Raqe
Abushanan, Alwaleed
Alasqah, Mohammed
Alsakr, Abdulaziz Mohammad
Alkharaan, Hassan
author_sort Alqahtani, Abdullah Saad
collection PubMed
description (1) Background: The purpose of this prospective study was to determine the changes in primary hemodynamic parameters and oxygen saturation in systemically healthy patients during the surgical procedure involving crown lengthening. (2) Methods: A total of 44 patients who required a crown-lengthening procedure in a single tooth in the maxillary arch were included in this study. Heart rate (HR), blood pressure (BP) and oxygen saturation (SpO(2)) were measured in all the subjects at three different intervals: before injecting the anesthetic (T1), after the anesthetic injection (T2) and after the procedure (T3). Descriptive statistics were computed, and observations were recorded as mean and standard deviation (SD). Analysis of variance (ANOVA) was used to compare the mean observation within parameters at different time intervals. (3) Results: All primary hemodynamic parameters were increased in the T2 phase over T1 and decreased in the T3 phase over T2. However, SpO(2) decreased in both the T2 and T3 phases compared to the initial T1 phase. No significant differences were observed among the primary hemodynamic variables. However, SpO(2) showed a significant difference (p = 0.013) among the T1, T2 and T3 phases. (4) Conclusions: Further study with larger sample size is required in order to analyze the accurate hemodynamic alterations.
format Online
Article
Text
id pubmed-9141731
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91417312022-05-28 Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study Alqahtani, Abdullah Saad Sharanesha, Rajashekhara Bhari Gufran, Khalid Alqhtani, Nasser Raqe Abushanan, Alwaleed Alasqah, Mohammed Alsakr, Abdulaziz Mohammad Alkharaan, Hassan Healthcare (Basel) Article (1) Background: The purpose of this prospective study was to determine the changes in primary hemodynamic parameters and oxygen saturation in systemically healthy patients during the surgical procedure involving crown lengthening. (2) Methods: A total of 44 patients who required a crown-lengthening procedure in a single tooth in the maxillary arch were included in this study. Heart rate (HR), blood pressure (BP) and oxygen saturation (SpO(2)) were measured in all the subjects at three different intervals: before injecting the anesthetic (T1), after the anesthetic injection (T2) and after the procedure (T3). Descriptive statistics were computed, and observations were recorded as mean and standard deviation (SD). Analysis of variance (ANOVA) was used to compare the mean observation within parameters at different time intervals. (3) Results: All primary hemodynamic parameters were increased in the T2 phase over T1 and decreased in the T3 phase over T2. However, SpO(2) decreased in both the T2 and T3 phases compared to the initial T1 phase. No significant differences were observed among the primary hemodynamic variables. However, SpO(2) showed a significant difference (p = 0.013) among the T1, T2 and T3 phases. (4) Conclusions: Further study with larger sample size is required in order to analyze the accurate hemodynamic alterations. MDPI 2022-05-16 /pmc/articles/PMC9141731/ /pubmed/35628056 http://dx.doi.org/10.3390/healthcare10050919 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Alqahtani, Abdullah Saad
Sharanesha, Rajashekhara Bhari
Gufran, Khalid
Alqhtani, Nasser Raqe
Abushanan, Alwaleed
Alasqah, Mohammed
Alsakr, Abdulaziz Mohammad
Alkharaan, Hassan
Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title_full Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title_fullStr Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title_full_unstemmed Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title_short Variation in Hemodynamic Characteristics during Periodontal Crown-Lengthening Surgical Procedure: An Uncontrolled Cohort Study
title_sort variation in hemodynamic characteristics during periodontal crown-lengthening surgical procedure: an uncontrolled cohort study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9141731/
https://www.ncbi.nlm.nih.gov/pubmed/35628056
http://dx.doi.org/10.3390/healthcare10050919
work_keys_str_mv AT alqahtaniabdullahsaad variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT sharanesharajashekharabhari variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT gufrankhalid variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT alqhtaninasserraqe variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT abushananalwaleed variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT alasqahmohammed variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT alsakrabdulazizmohammad variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy
AT alkharaanhassan variationinhemodynamiccharacteristicsduringperiodontalcrownlengtheningsurgicalprocedureanuncontrolledcohortstudy