Cargando…

Endobronchial blood-patch: A novel technique for a persistent pleural air leak

INTRODUCTION: Patients with severe COVID-19 Pneumonia requiring prolonged mechanical ventilation have an increased incidence of pneumothorax. Mechanically ventilated patients who are critically ill and develop a persistent air leak from pneumothorax are poor candidates for surgical repair. As the pe...

Descripción completa

Detalles Bibliográficos
Autores principales: Durrance, Richard J., D'Souza, Kenneth G., Obata, Reiichiro, Bradley, Ellen C., Perwaiz, Muhammad K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9142177/
https://www.ncbi.nlm.nih.gov/pubmed/35656093
http://dx.doi.org/10.1016/j.rmcr.2022.101670
_version_ 1784715514973519872
author Durrance, Richard J.
D'Souza, Kenneth G.
Obata, Reiichiro
Bradley, Ellen C.
Perwaiz, Muhammad K.
author_facet Durrance, Richard J.
D'Souza, Kenneth G.
Obata, Reiichiro
Bradley, Ellen C.
Perwaiz, Muhammad K.
author_sort Durrance, Richard J.
collection PubMed
description INTRODUCTION: Patients with severe COVID-19 Pneumonia requiring prolonged mechanical ventilation have an increased incidence of pneumothorax. Mechanically ventilated patients who are critically ill and develop a persistent air leak from pneumothorax are poor candidates for surgical repair. As the persistent air leak can be a significant barrier to vent-weaning and clinical stability, these patients present a unique clinical challenge. CLINICAL CASE: A 65-year-old male intubated and on prolonged mechanical ventilation for severe COVID-19 Pneumonia developed a pneumothorax complicated by a persistent alveolar-pleural fistula with a persistent air-leak. Given his critical state with ongoing pressor requirements and elevated vent requirements, surgical repair was not an option. A bedside bronchoscopy occlusion study with isolation of the air leak, and subsequent autologous endobronchial blood-patch repair with thrombin was performed with rapid and definitive resolution of the air leak. The patient progressed favorably, ultimately being weaned from the ventilator, decannulated, and walking out of the hospital. CONCLUSION: In critically ill ventilated patients with pneumothorax complicated by a persistent air-leak, bedside endobronchial evaluation and blood-patch repair is a feasible approach to management.
format Online
Article
Text
id pubmed-9142177
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91421772022-05-31 Endobronchial blood-patch: A novel technique for a persistent pleural air leak Durrance, Richard J. D'Souza, Kenneth G. Obata, Reiichiro Bradley, Ellen C. Perwaiz, Muhammad K. Respir Med Case Rep Case Report INTRODUCTION: Patients with severe COVID-19 Pneumonia requiring prolonged mechanical ventilation have an increased incidence of pneumothorax. Mechanically ventilated patients who are critically ill and develop a persistent air leak from pneumothorax are poor candidates for surgical repair. As the persistent air leak can be a significant barrier to vent-weaning and clinical stability, these patients present a unique clinical challenge. CLINICAL CASE: A 65-year-old male intubated and on prolonged mechanical ventilation for severe COVID-19 Pneumonia developed a pneumothorax complicated by a persistent alveolar-pleural fistula with a persistent air-leak. Given his critical state with ongoing pressor requirements and elevated vent requirements, surgical repair was not an option. A bedside bronchoscopy occlusion study with isolation of the air leak, and subsequent autologous endobronchial blood-patch repair with thrombin was performed with rapid and definitive resolution of the air leak. The patient progressed favorably, ultimately being weaned from the ventilator, decannulated, and walking out of the hospital. CONCLUSION: In critically ill ventilated patients with pneumothorax complicated by a persistent air-leak, bedside endobronchial evaluation and blood-patch repair is a feasible approach to management. Elsevier 2022-05-28 /pmc/articles/PMC9142177/ /pubmed/35656093 http://dx.doi.org/10.1016/j.rmcr.2022.101670 Text en © 2022 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Durrance, Richard J.
D'Souza, Kenneth G.
Obata, Reiichiro
Bradley, Ellen C.
Perwaiz, Muhammad K.
Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title_full Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title_fullStr Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title_full_unstemmed Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title_short Endobronchial blood-patch: A novel technique for a persistent pleural air leak
title_sort endobronchial blood-patch: a novel technique for a persistent pleural air leak
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9142177/
https://www.ncbi.nlm.nih.gov/pubmed/35656093
http://dx.doi.org/10.1016/j.rmcr.2022.101670
work_keys_str_mv AT durrancerichardj endobronchialbloodpatchanoveltechniqueforapersistentpleuralairleak
AT dsouzakennethg endobronchialbloodpatchanoveltechniqueforapersistentpleuralairleak
AT obatareiichiro endobronchialbloodpatchanoveltechniqueforapersistentpleuralairleak
AT bradleyellenc endobronchialbloodpatchanoveltechniqueforapersistentpleuralairleak
AT perwaizmuhammadk endobronchialbloodpatchanoveltechniqueforapersistentpleuralairleak