Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment

Background and Objectives: Spine surgery using a percutaneous pedicle screw placement (PPSP) is widely implemented for spinal trauma. However, percutaneous systems have been reported to have weak screw–rod connections. In this study, conventional open and percutaneous systems were biomechanically ev...

Descripción completa

Detalles Bibliográficos
Autores principales: Oda, Yoshiaki, Takigawa, Tomoyuki, Ito, Yasuo, Misawa, Haruo, Tetsunaga, Tomoko, Uotani, Koji, Ozaki, Toshifumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9143153/
https://www.ncbi.nlm.nih.gov/pubmed/35629982
http://dx.doi.org/10.3390/medicina58050565
_version_ 1784715735438721024
author Oda, Yoshiaki
Takigawa, Tomoyuki
Ito, Yasuo
Misawa, Haruo
Tetsunaga, Tomoko
Uotani, Koji
Ozaki, Toshifumi
author_facet Oda, Yoshiaki
Takigawa, Tomoyuki
Ito, Yasuo
Misawa, Haruo
Tetsunaga, Tomoko
Uotani, Koji
Ozaki, Toshifumi
author_sort Oda, Yoshiaki
collection PubMed
description Background and Objectives: Spine surgery using a percutaneous pedicle screw placement (PPSP) is widely implemented for spinal trauma. However, percutaneous systems have been reported to have weak screw–rod connections. In this study, conventional open and percutaneous systems were biomechanically evaluated and compared. Material and Methods: The experiments were performed in two stages: the first stage was a break test, whereas the second stage was a fatigue test. Four systems were used for the experiments. System 1 was intended for conventional open surgery (titanium rod with a 6.0 mm diameter, using a clamp connecting mechanism). System 2 was a percutaneous pedicle screw (PPS) system for trauma (titanium alloy rod with a 6.0 mm diameter, using ball ring connections). System 3 was a PPS system for trauma (cobalt–chromium alloy rod with a 6.0 mm diameter, using sagittal adjusting screw connections). System 4 was a general-purpose PPS system (titanium alloy rod with a 5.5 mm diameter, using a mechanism where the adapter in the head holds down the screw). Results: Stiffness values of 54.8 N/mm, 43.1 N/mm, 90.9 N/mm, and 39.3 N/mm were reported for systems 1, 2, 3, and 4, respectively. The average number of load cycles in the fatigue test was 134,393, 40,980, 1,550,389, and 147,724 for systems 1 to 4, respectively. At the end of the test, the displacements were 0.2 mm, 16.9 mm, 1.2 mm, and 8.6 mm, respectively. System 1, with a locking mechanism, showed the least displacement at the end of the test. Conclusion: A few PPS systems showed better results in terms on stiffness and life than the open system. The experiments showed that mechanical strength varies depending on the spinal implant. The experiments conducted are essential and significant to provide the mechanical strength required for surgical reconstruction.
format Online
Article
Text
id pubmed-9143153
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91431532022-05-29 Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment Oda, Yoshiaki Takigawa, Tomoyuki Ito, Yasuo Misawa, Haruo Tetsunaga, Tomoko Uotani, Koji Ozaki, Toshifumi Medicina (Kaunas) Article Background and Objectives: Spine surgery using a percutaneous pedicle screw placement (PPSP) is widely implemented for spinal trauma. However, percutaneous systems have been reported to have weak screw–rod connections. In this study, conventional open and percutaneous systems were biomechanically evaluated and compared. Material and Methods: The experiments were performed in two stages: the first stage was a break test, whereas the second stage was a fatigue test. Four systems were used for the experiments. System 1 was intended for conventional open surgery (titanium rod with a 6.0 mm diameter, using a clamp connecting mechanism). System 2 was a percutaneous pedicle screw (PPS) system for trauma (titanium alloy rod with a 6.0 mm diameter, using ball ring connections). System 3 was a PPS system for trauma (cobalt–chromium alloy rod with a 6.0 mm diameter, using sagittal adjusting screw connections). System 4 was a general-purpose PPS system (titanium alloy rod with a 5.5 mm diameter, using a mechanism where the adapter in the head holds down the screw). Results: Stiffness values of 54.8 N/mm, 43.1 N/mm, 90.9 N/mm, and 39.3 N/mm were reported for systems 1, 2, 3, and 4, respectively. The average number of load cycles in the fatigue test was 134,393, 40,980, 1,550,389, and 147,724 for systems 1 to 4, respectively. At the end of the test, the displacements were 0.2 mm, 16.9 mm, 1.2 mm, and 8.6 mm, respectively. System 1, with a locking mechanism, showed the least displacement at the end of the test. Conclusion: A few PPS systems showed better results in terms on stiffness and life than the open system. The experiments showed that mechanical strength varies depending on the spinal implant. The experiments conducted are essential and significant to provide the mechanical strength required for surgical reconstruction. MDPI 2022-04-20 /pmc/articles/PMC9143153/ /pubmed/35629982 http://dx.doi.org/10.3390/medicina58050565 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oda, Yoshiaki
Takigawa, Tomoyuki
Ito, Yasuo
Misawa, Haruo
Tetsunaga, Tomoko
Uotani, Koji
Ozaki, Toshifumi
Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title_full Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title_fullStr Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title_full_unstemmed Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title_short Mechanical Study of Various Pedicle Screw Systems including Percutaneous Pedicle Screw in Trauma Treatment
title_sort mechanical study of various pedicle screw systems including percutaneous pedicle screw in trauma treatment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9143153/
https://www.ncbi.nlm.nih.gov/pubmed/35629982
http://dx.doi.org/10.3390/medicina58050565
work_keys_str_mv AT odayoshiaki mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT takigawatomoyuki mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT itoyasuo mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT misawaharuo mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT tetsunagatomoko mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT uotanikoji mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment
AT ozakitoshifumi mechanicalstudyofvariouspediclescrewsystemsincludingpercutaneouspediclescrewintraumatreatment