Cargando…

Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a sys...

Descripción completa

Detalles Bibliográficos
Autores principales: Hung, Yu-Hui, Lai, Tai-Shuan, Belmouaz, Mohamed, Tu, Ya-Chun, Lai, Chun-Fu, Lin, Shuei-Liong, Chen, Yung-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144787/
https://www.ncbi.nlm.nih.gov/pubmed/35629769
http://dx.doi.org/10.3390/membranes12050443
_version_ 1784716133314592768
author Hung, Yu-Hui
Lai, Tai-Shuan
Belmouaz, Mohamed
Tu, Ya-Chun
Lai, Chun-Fu
Lin, Shuei-Liong
Chen, Yung-Ming
author_facet Hung, Yu-Hui
Lai, Tai-Shuan
Belmouaz, Mohamed
Tu, Ya-Chun
Lai, Chun-Fu
Lin, Shuei-Liong
Chen, Yung-Ming
author_sort Hung, Yu-Hui
collection PubMed
description The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a systematic literature review and meta-analysis of randomized controlled trials to investigate whether MCO membranes efficiently increase the reduction ratio of middle molecules, and to explore the potential clinical applications of MCO membranes. We selected articles that compared beta 2-microglobulin (β2M), kappa free light chain (κFLC), lambda free light chain (λFLC), interleukin-6 (IL-6), and albumin levels among patients undergoing hemodialysis. Five randomized studies with 328 patients were included. The meta-analysis demonstrated a significantly higher reduction ratio of serum β2M (p < 0.0001), κFLC (p < 0.0001), and λFLC (p = 0.02) in the MCO group. No significant difference was found in serum IL-6 levels after hemodialysis. Albumin loss was observed in the MCO group (p = 0.04). In conclusion, this meta-analysis study demonstrated the MCO membranes’ superior ability to clear β2M, κFLC, and λFLC. Serum albumin loss is an issue and should be monitored. Further studies are expected to identify whether MCO membranes could significantly improve clinical outcomes and overall survival.
format Online
Article
Text
id pubmed-9144787
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91447872022-05-29 Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials Hung, Yu-Hui Lai, Tai-Shuan Belmouaz, Mohamed Tu, Ya-Chun Lai, Chun-Fu Lin, Shuei-Liong Chen, Yung-Ming Membranes (Basel) Systematic Review The use of medium cut-off (MCO) polyarylethersulfone and polyvinylpyrrolidone blend membrane is an emerging mode in hemodialysis. Recent studies have shown that MCO membranes exhibit a middle high molecular weight uremic toxin clearance superior to standard high flux hemodialysis. We conducted a systematic literature review and meta-analysis of randomized controlled trials to investigate whether MCO membranes efficiently increase the reduction ratio of middle molecules, and to explore the potential clinical applications of MCO membranes. We selected articles that compared beta 2-microglobulin (β2M), kappa free light chain (κFLC), lambda free light chain (λFLC), interleukin-6 (IL-6), and albumin levels among patients undergoing hemodialysis. Five randomized studies with 328 patients were included. The meta-analysis demonstrated a significantly higher reduction ratio of serum β2M (p < 0.0001), κFLC (p < 0.0001), and λFLC (p = 0.02) in the MCO group. No significant difference was found in serum IL-6 levels after hemodialysis. Albumin loss was observed in the MCO group (p = 0.04). In conclusion, this meta-analysis study demonstrated the MCO membranes’ superior ability to clear β2M, κFLC, and λFLC. Serum albumin loss is an issue and should be monitored. Further studies are expected to identify whether MCO membranes could significantly improve clinical outcomes and overall survival. MDPI 2022-04-20 /pmc/articles/PMC9144787/ /pubmed/35629769 http://dx.doi.org/10.3390/membranes12050443 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Hung, Yu-Hui
Lai, Tai-Shuan
Belmouaz, Mohamed
Tu, Ya-Chun
Lai, Chun-Fu
Lin, Shuei-Liong
Chen, Yung-Ming
Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title_full Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title_fullStr Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title_full_unstemmed Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title_short Effects of Medium Cut-Off Polyarylethersulfone and Polyvinylpyrrolidone Blend Membrane Dialyzers in Hemodialysis Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
title_sort effects of medium cut-off polyarylethersulfone and polyvinylpyrrolidone blend membrane dialyzers in hemodialysis patients: a systematic review and meta-analysis of randomized controlled trials
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144787/
https://www.ncbi.nlm.nih.gov/pubmed/35629769
http://dx.doi.org/10.3390/membranes12050443
work_keys_str_mv AT hungyuhui effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT laitaishuan effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT belmouazmohamed effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT tuyachun effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT laichunfu effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT linshueiliong effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials
AT chenyungming effectsofmediumcutoffpolyarylethersulfoneandpolyvinylpyrrolidoneblendmembranedialyzersinhemodialysispatientsasystematicreviewandmetaanalysisofrandomizedcontrolledtrials