Cargando…
Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144921/ https://www.ncbi.nlm.nih.gov/pubmed/35631989 http://dx.doi.org/10.3390/polym14102107 |
_version_ | 1784716166233587712 |
---|---|
author | Pop, Silvia Izabella Dudescu, Mircea Mihali, Sorin Gheorghe Păcurar, Mariana Bratu, Dana Cristina |
author_facet | Pop, Silvia Izabella Dudescu, Mircea Mihali, Sorin Gheorghe Păcurar, Mariana Bratu, Dana Cristina |
author_sort | Pop, Silvia Izabella |
collection | PubMed |
description | Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides. |
format | Online Article Text |
id | pubmed-9144921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91449212022-05-29 Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement Pop, Silvia Izabella Dudescu, Mircea Mihali, Sorin Gheorghe Păcurar, Mariana Bratu, Dana Cristina Polymers (Basel) Article Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides. MDPI 2022-05-21 /pmc/articles/PMC9144921/ /pubmed/35631989 http://dx.doi.org/10.3390/polym14102107 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Pop, Silvia Izabella Dudescu, Mircea Mihali, Sorin Gheorghe Păcurar, Mariana Bratu, Dana Cristina Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title | Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title_full | Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title_fullStr | Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title_full_unstemmed | Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title_short | Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement |
title_sort | effects of disinfection and steam sterilization on the mechanical properties of 3d sla- and dlp-printed surgical guides for orthodontic implant placement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144921/ https://www.ncbi.nlm.nih.gov/pubmed/35631989 http://dx.doi.org/10.3390/polym14102107 |
work_keys_str_mv | AT popsilviaizabella effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement AT dudescumircea effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement AT mihalisoringheorghe effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement AT pacurarmariana effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement AT bratudanacristina effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement |