Cargando…

Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement

Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the...

Descripción completa

Detalles Bibliográficos
Autores principales: Pop, Silvia Izabella, Dudescu, Mircea, Mihali, Sorin Gheorghe, Păcurar, Mariana, Bratu, Dana Cristina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144921/
https://www.ncbi.nlm.nih.gov/pubmed/35631989
http://dx.doi.org/10.3390/polym14102107
_version_ 1784716166233587712
author Pop, Silvia Izabella
Dudescu, Mircea
Mihali, Sorin Gheorghe
Păcurar, Mariana
Bratu, Dana Cristina
author_facet Pop, Silvia Izabella
Dudescu, Mircea
Mihali, Sorin Gheorghe
Păcurar, Mariana
Bratu, Dana Cristina
author_sort Pop, Silvia Izabella
collection PubMed
description Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides.
format Online
Article
Text
id pubmed-9144921
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91449212022-05-29 Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement Pop, Silvia Izabella Dudescu, Mircea Mihali, Sorin Gheorghe Păcurar, Mariana Bratu, Dana Cristina Polymers (Basel) Article Three-dimensional printed surgical guides increase the precision of orthodontic mini-implant placement. The purpose of this research was to investigate the effects of disinfection and of two types of autoclave sterilization on the mechanical properties of 3D printed surgical guides obtained via the SLA (stereolithography) and DLP (digital light processing) printing methods. A total of 96 standard specimens (48 SLA and 48 DLP) were printed to analyze the tensile and flexural properties of the materials. A total of 80 surgical guide (40 SLA and 40 DLP) specimens from each printing method were classified into four groups: CG (control group); G1, disinfected with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany); G2, autoclave-sterilized (121 °C); and G3, autoclave-sterilized (134 °C). Significant differences in the maximum compressive load were determined between the groups comprising the DLP-(p < 0.001) and the SLA- (p < 0.001) printed surgical guides. Groups G2 (p = 0.001) and G3 (p = 0.029) showed significant parameter modifications compared with the CG. Disinfection with 4% Gigasept (Gigasept Instru AF; Schülke & Mayer Gmbh, Norderstedt, Germany) is suitable both for SLA- and DLP-printed surgical guides. Heat sterilization at both 121 °C and 134 °C modified the mechanical properties of the surgical guides. MDPI 2022-05-21 /pmc/articles/PMC9144921/ /pubmed/35631989 http://dx.doi.org/10.3390/polym14102107 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pop, Silvia Izabella
Dudescu, Mircea
Mihali, Sorin Gheorghe
Păcurar, Mariana
Bratu, Dana Cristina
Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title_full Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title_fullStr Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title_full_unstemmed Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title_short Effects of Disinfection and Steam Sterilization on the Mechanical Properties of 3D SLA- and DLP-Printed Surgical Guides for Orthodontic Implant Placement
title_sort effects of disinfection and steam sterilization on the mechanical properties of 3d sla- and dlp-printed surgical guides for orthodontic implant placement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9144921/
https://www.ncbi.nlm.nih.gov/pubmed/35631989
http://dx.doi.org/10.3390/polym14102107
work_keys_str_mv AT popsilviaizabella effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement
AT dudescumircea effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement
AT mihalisoringheorghe effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement
AT pacurarmariana effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement
AT bratudanacristina effectsofdisinfectionandsteamsterilizationonthemechanicalpropertiesof3dslaanddlpprintedsurgicalguidesfororthodonticimplantplacement