New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9145760/ https://www.ncbi.nlm.nih.gov/pubmed/35631825 http://dx.doi.org/10.3390/polym14101942 |
_version_ | 1784716394334519296 |
---|---|
author | Abd-Rabboh, Hisham S. M. E. Amr, Abdel El-Galil Almehizia, Abdulrahman A. Naglah, Ahmed M. H. Kamel, Ayman |
author_facet | Abd-Rabboh, Hisham S. M. E. Amr, Abdel El-Galil Almehizia, Abdulrahman A. Naglah, Ahmed M. H. Kamel, Ayman |
author_sort | Abd-Rabboh, Hisham S. M. |
collection | PubMed |
description | Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R(2) = 0.997) over the linear range of 4.5 × 10(−6)–1.0 × 10(−3) M with a detection limit of 3.0 × 10(−6) M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection. |
format | Online Article Text |
id | pubmed-9145760 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91457602022-05-29 New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment Abd-Rabboh, Hisham S. M. E. Amr, Abdel El-Galil Almehizia, Abdulrahman A. Naglah, Ahmed M. H. Kamel, Ayman Polymers (Basel) Article Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R(2) = 0.997) over the linear range of 4.5 × 10(−6)–1.0 × 10(−3) M with a detection limit of 3.0 × 10(−6) M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection. MDPI 2022-05-10 /pmc/articles/PMC9145760/ /pubmed/35631825 http://dx.doi.org/10.3390/polym14101942 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Abd-Rabboh, Hisham S. M. E. Amr, Abdel El-Galil Almehizia, Abdulrahman A. Naglah, Ahmed M. H. Kamel, Ayman New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title | New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title_full | New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title_fullStr | New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title_full_unstemmed | New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title_short | New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment |
title_sort | new potentiometric screen-printed platforms modified with reduced graphene oxide and based on man-made imprinted receptors for caffeine assessment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9145760/ https://www.ncbi.nlm.nih.gov/pubmed/35631825 http://dx.doi.org/10.3390/polym14101942 |
work_keys_str_mv | AT abdrabbohhishamsm newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment AT eamrabdelelgalil newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment AT almehiziaabdulrahmana newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment AT naglahahmedm newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment AT hkamelayman newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment |