Cargando…

New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment

Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from...

Descripción completa

Detalles Bibliográficos
Autores principales: Abd-Rabboh, Hisham S. M., E. Amr, Abdel El-Galil, Almehizia, Abdulrahman A., Naglah, Ahmed M., H. Kamel, Ayman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9145760/
https://www.ncbi.nlm.nih.gov/pubmed/35631825
http://dx.doi.org/10.3390/polym14101942
_version_ 1784716394334519296
author Abd-Rabboh, Hisham S. M.
E. Amr, Abdel El-Galil
Almehizia, Abdulrahman A.
Naglah, Ahmed M.
H. Kamel, Ayman
author_facet Abd-Rabboh, Hisham S. M.
E. Amr, Abdel El-Galil
Almehizia, Abdulrahman A.
Naglah, Ahmed M.
H. Kamel, Ayman
author_sort Abd-Rabboh, Hisham S. M.
collection PubMed
description Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R(2) = 0.997) over the linear range of 4.5 × 10(−6)–1.0 × 10(−3) M with a detection limit of 3.0 × 10(−6) M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection.
format Online
Article
Text
id pubmed-9145760
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91457602022-05-29 New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment Abd-Rabboh, Hisham S. M. E. Amr, Abdel El-Galil Almehizia, Abdulrahman A. Naglah, Ahmed M. H. Kamel, Ayman Polymers (Basel) Article Caffeine is a psychoactive drug that is administered as a class II psychotropic substance. It is also considered a component of analgesics and cold medicines. Excessive intake of caffeine may lead to severe health damage or drug addiction problems. The assessment of normal caffeine consumption from abusive use is not conclusive, and the cut-off value for biological samples has not been established. Herein, new cost-effective and robust all-solid-state platforms based on potentiometric transduction were fabricated and successfully utilized for caffeine assessment. The platforms were modified with reduced graphene oxide (rGO). Tailored caffeine-imprinted polymeric beads (MIPs) based on methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) were prepared, characterized, and used as recognition receptors in the presented potentiometric sensing devices. In 50 mM MES buffer, the sensors exhibited a slope response of 51.2 ± 0.9 mV/decade (n = 6, R(2) = 0.997) over the linear range of 4.5 × 10(−6)–1.0 × 10(−3) M with a detection limit of 3.0 × 10(−6) M. They exhibited fast detection of caffeinium ions with less than 5 s response time (<5 s). The behavior of the presented sensors towards caffeinium ions over many common organic and inorganic cations was evaluated using the modified separate solution method (MSSM). Inter-day and intra-day precision for the presented analytical device was also evaluated. Successful applications of the presented caffeine sensors for caffeine determination in commercial tea and coffee and different pharmaceutical formulations were carried out. The data obtained were compared with those obtained by the standard liquid chromatographic approach. The presented analytical device can be considered an attractive tool for caffeine determination because of its affordability and vast availability, particularly when combined with potentiometric detection. MDPI 2022-05-10 /pmc/articles/PMC9145760/ /pubmed/35631825 http://dx.doi.org/10.3390/polym14101942 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abd-Rabboh, Hisham S. M.
E. Amr, Abdel El-Galil
Almehizia, Abdulrahman A.
Naglah, Ahmed M.
H. Kamel, Ayman
New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title_full New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title_fullStr New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title_full_unstemmed New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title_short New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment
title_sort new potentiometric screen-printed platforms modified with reduced graphene oxide and based on man-made imprinted receptors for caffeine assessment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9145760/
https://www.ncbi.nlm.nih.gov/pubmed/35631825
http://dx.doi.org/10.3390/polym14101942
work_keys_str_mv AT abdrabbohhishamsm newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment
AT eamrabdelelgalil newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment
AT almehiziaabdulrahmana newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment
AT naglahahmedm newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment
AT hkamelayman newpotentiometricscreenprintedplatformsmodifiedwithreducedgrapheneoxideandbasedonmanmadeimprintedreceptorsforcaffeineassessment