Cargando…

A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor

Direct potentiometric measurements using solid-state sensors have a great potential for thiabendazole (TBZ) determination, considering simplicity, accuracy, and low cost. Modifying the sensing material of the sensor with multi-walled carbon nanotubes (MWCNTs) leads to improved analytical properties...

Descripción completa

Detalles Bibliográficos
Autores principales: Dandić, Andrea, Novak, Ivana, Jozanović, Marija, Pukleš, Iva, Széchenyi, Aleksandar, Budetić, Mateja, Samardžić, Mirela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147095/
https://www.ncbi.nlm.nih.gov/pubmed/35632191
http://dx.doi.org/10.3390/s22103785
_version_ 1784716723900907520
author Dandić, Andrea
Novak, Ivana
Jozanović, Marija
Pukleš, Iva
Széchenyi, Aleksandar
Budetić, Mateja
Samardžić, Mirela
author_facet Dandić, Andrea
Novak, Ivana
Jozanović, Marija
Pukleš, Iva
Széchenyi, Aleksandar
Budetić, Mateja
Samardžić, Mirela
author_sort Dandić, Andrea
collection PubMed
description Direct potentiometric measurements using solid-state sensors have a great potential for thiabendazole (TBZ) determination, considering simplicity, accuracy, and low cost. Modifying the sensing material of the sensor with multi-walled carbon nanotubes (MWCNTs) leads to improved analytical properties of the sensor. In this study, a new potentiometric solid-state sensor for TBZ determination, based on MWCNTs modified with a sulfate group, and TBZ ion as sensing material was developed. The sensor exhibited a Nernstian response for TBZ (60.4 mV/decade of activity) in a working range between 8.6 × 10(−7) and 1.0 × 10(−3) M. The detection limit for TBZ was 6.2 × 10(−7) M. The response time of the sensor for TBZ was 8 s, and its signal drift was only 1.7 mV/h. The new sensor is applicable for direct potentiometric determination of TBZ in complex real samples, such as fruit peel. The accuracy of TBZ determination is confirmed using the standard addition method.
format Online
Article
Text
id pubmed-9147095
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91470952022-05-29 A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor Dandić, Andrea Novak, Ivana Jozanović, Marija Pukleš, Iva Széchenyi, Aleksandar Budetić, Mateja Samardžić, Mirela Sensors (Basel) Article Direct potentiometric measurements using solid-state sensors have a great potential for thiabendazole (TBZ) determination, considering simplicity, accuracy, and low cost. Modifying the sensing material of the sensor with multi-walled carbon nanotubes (MWCNTs) leads to improved analytical properties of the sensor. In this study, a new potentiometric solid-state sensor for TBZ determination, based on MWCNTs modified with a sulfate group, and TBZ ion as sensing material was developed. The sensor exhibited a Nernstian response for TBZ (60.4 mV/decade of activity) in a working range between 8.6 × 10(−7) and 1.0 × 10(−3) M. The detection limit for TBZ was 6.2 × 10(−7) M. The response time of the sensor for TBZ was 8 s, and its signal drift was only 1.7 mV/h. The new sensor is applicable for direct potentiometric determination of TBZ in complex real samples, such as fruit peel. The accuracy of TBZ determination is confirmed using the standard addition method. MDPI 2022-05-16 /pmc/articles/PMC9147095/ /pubmed/35632191 http://dx.doi.org/10.3390/s22103785 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dandić, Andrea
Novak, Ivana
Jozanović, Marija
Pukleš, Iva
Széchenyi, Aleksandar
Budetić, Mateja
Samardžić, Mirela
A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title_full A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title_fullStr A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title_full_unstemmed A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title_short A New, MWCNT-Based, Solid-State Thiabendazole-Selective Sensor
title_sort new, mwcnt-based, solid-state thiabendazole-selective sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147095/
https://www.ncbi.nlm.nih.gov/pubmed/35632191
http://dx.doi.org/10.3390/s22103785
work_keys_str_mv AT dandicandrea anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT novakivana anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT jozanovicmarija anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT puklesiva anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT szechenyialeksandar anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT budeticmateja anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT samardzicmirela anewmwcntbasedsolidstatethiabendazoleselectivesensor
AT dandicandrea newmwcntbasedsolidstatethiabendazoleselectivesensor
AT novakivana newmwcntbasedsolidstatethiabendazoleselectivesensor
AT jozanovicmarija newmwcntbasedsolidstatethiabendazoleselectivesensor
AT puklesiva newmwcntbasedsolidstatethiabendazoleselectivesensor
AT szechenyialeksandar newmwcntbasedsolidstatethiabendazoleselectivesensor
AT budeticmateja newmwcntbasedsolidstatethiabendazoleselectivesensor
AT samardzicmirela newmwcntbasedsolidstatethiabendazoleselectivesensor