Cargando…
Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147434/ https://www.ncbi.nlm.nih.gov/pubmed/35629171 http://dx.doi.org/10.3390/jpm12050749 |
_version_ | 1784716806543376384 |
---|---|
author | Martín-Martín, Jaime Jiménez-Partinen, Ariadna De-Torres, Irene Escriche-Escuder, Adrian González-Sánchez, Manuel Muro-Culebras, Antonio Roldán-Jiménez, Cristina Ruiz-Muñoz, María Mayoral-Cleries, Fermín Biró, Attila Tang, Wen Nikolova, Borjanka Salvatore, Alfredo Cuesta-Vargas, Antonio I. |
author_facet | Martín-Martín, Jaime Jiménez-Partinen, Ariadna De-Torres, Irene Escriche-Escuder, Adrian González-Sánchez, Manuel Muro-Culebras, Antonio Roldán-Jiménez, Cristina Ruiz-Muñoz, María Mayoral-Cleries, Fermín Biró, Attila Tang, Wen Nikolova, Borjanka Salvatore, Alfredo Cuesta-Vargas, Antonio I. |
author_sort | Martín-Martín, Jaime |
collection | PubMed |
description | The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test consisted of a 1 min walk for participants to become accustomed to the treadmill, followed by a 2 min trial at ten pre-set speeds. Data from both sensors were collected in real-time. Intraclass correlation coefficient (ICC) was used to evaluate the equality of characteristics obtained by both sensors: maximum peaks, minimum peaks, and the mean of the complete signal (sequence of acceleration values along the time) by each axis and speed were extracted to evaluate the equality of characteristics obtained with LIS2DH12 compared to Actigraph. Intraclass correlation coefficient (ICC) was extracted, and a standard deviation of the mean was obtained from the data. Our results show that LIS2DH12 measurements present more reliability than Actigraph GT9X, ICC > 0.8 at three axes. This study concludes that LIS2DH12 is as reliable and accurate as Actigraph GT9X Link and, therefore, would be a suitable tool for future kinematic studies. |
format | Online Article Text |
id | pubmed-9147434 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91474342022-05-29 Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code Martín-Martín, Jaime Jiménez-Partinen, Ariadna De-Torres, Irene Escriche-Escuder, Adrian González-Sánchez, Manuel Muro-Culebras, Antonio Roldán-Jiménez, Cristina Ruiz-Muñoz, María Mayoral-Cleries, Fermín Biró, Attila Tang, Wen Nikolova, Borjanka Salvatore, Alfredo Cuesta-Vargas, Antonio I. J Pers Med Article The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test consisted of a 1 min walk for participants to become accustomed to the treadmill, followed by a 2 min trial at ten pre-set speeds. Data from both sensors were collected in real-time. Intraclass correlation coefficient (ICC) was used to evaluate the equality of characteristics obtained by both sensors: maximum peaks, minimum peaks, and the mean of the complete signal (sequence of acceleration values along the time) by each axis and speed were extracted to evaluate the equality of characteristics obtained with LIS2DH12 compared to Actigraph. Intraclass correlation coefficient (ICC) was extracted, and a standard deviation of the mean was obtained from the data. Our results show that LIS2DH12 measurements present more reliability than Actigraph GT9X, ICC > 0.8 at three axes. This study concludes that LIS2DH12 is as reliable and accurate as Actigraph GT9X Link and, therefore, would be a suitable tool for future kinematic studies. MDPI 2022-05-05 /pmc/articles/PMC9147434/ /pubmed/35629171 http://dx.doi.org/10.3390/jpm12050749 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Martín-Martín, Jaime Jiménez-Partinen, Ariadna De-Torres, Irene Escriche-Escuder, Adrian González-Sánchez, Manuel Muro-Culebras, Antonio Roldán-Jiménez, Cristina Ruiz-Muñoz, María Mayoral-Cleries, Fermín Biró, Attila Tang, Wen Nikolova, Borjanka Salvatore, Alfredo Cuesta-Vargas, Antonio I. Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title | Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title_full | Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title_fullStr | Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title_full_unstemmed | Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title_short | Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code |
title_sort | reliability study of inertial sensors lis2dh12 compared to actigraph gt9x: based on free code |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147434/ https://www.ncbi.nlm.nih.gov/pubmed/35629171 http://dx.doi.org/10.3390/jpm12050749 |
work_keys_str_mv | AT martinmartinjaime reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT jimenezpartinenariadna reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT detorresirene reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT escricheescuderadrian reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT gonzalezsanchezmanuel reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT muroculebrasantonio reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT roldanjimenezcristina reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT ruizmunozmaria reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT mayoralcleriesfermin reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT biroattila reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT tangwen reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT nikolovaborjanka reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT salvatorealfredo reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode AT cuestavargasantonioi reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode |