Cargando…

Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code

The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test...

Descripción completa

Detalles Bibliográficos
Autores principales: Martín-Martín, Jaime, Jiménez-Partinen, Ariadna, De-Torres, Irene, Escriche-Escuder, Adrian, González-Sánchez, Manuel, Muro-Culebras, Antonio, Roldán-Jiménez, Cristina, Ruiz-Muñoz, María, Mayoral-Cleries, Fermín, Biró, Attila, Tang, Wen, Nikolova, Borjanka, Salvatore, Alfredo, Cuesta-Vargas, Antonio I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147434/
https://www.ncbi.nlm.nih.gov/pubmed/35629171
http://dx.doi.org/10.3390/jpm12050749
_version_ 1784716806543376384
author Martín-Martín, Jaime
Jiménez-Partinen, Ariadna
De-Torres, Irene
Escriche-Escuder, Adrian
González-Sánchez, Manuel
Muro-Culebras, Antonio
Roldán-Jiménez, Cristina
Ruiz-Muñoz, María
Mayoral-Cleries, Fermín
Biró, Attila
Tang, Wen
Nikolova, Borjanka
Salvatore, Alfredo
Cuesta-Vargas, Antonio I.
author_facet Martín-Martín, Jaime
Jiménez-Partinen, Ariadna
De-Torres, Irene
Escriche-Escuder, Adrian
González-Sánchez, Manuel
Muro-Culebras, Antonio
Roldán-Jiménez, Cristina
Ruiz-Muñoz, María
Mayoral-Cleries, Fermín
Biró, Attila
Tang, Wen
Nikolova, Borjanka
Salvatore, Alfredo
Cuesta-Vargas, Antonio I.
author_sort Martín-Martín, Jaime
collection PubMed
description The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test consisted of a 1 min walk for participants to become accustomed to the treadmill, followed by a 2 min trial at ten pre-set speeds. Data from both sensors were collected in real-time. Intraclass correlation coefficient (ICC) was used to evaluate the equality of characteristics obtained by both sensors: maximum peaks, minimum peaks, and the mean of the complete signal (sequence of acceleration values along the time) by each axis and speed were extracted to evaluate the equality of characteristics obtained with LIS2DH12 compared to Actigraph. Intraclass correlation coefficient (ICC) was extracted, and a standard deviation of the mean was obtained from the data. Our results show that LIS2DH12 measurements present more reliability than Actigraph GT9X, ICC > 0.8 at three axes. This study concludes that LIS2DH12 is as reliable and accurate as Actigraph GT9X Link and, therefore, would be a suitable tool for future kinematic studies.
format Online
Article
Text
id pubmed-9147434
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91474342022-05-29 Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code Martín-Martín, Jaime Jiménez-Partinen, Ariadna De-Torres, Irene Escriche-Escuder, Adrian González-Sánchez, Manuel Muro-Culebras, Antonio Roldán-Jiménez, Cristina Ruiz-Muñoz, María Mayoral-Cleries, Fermín Biró, Attila Tang, Wen Nikolova, Borjanka Salvatore, Alfredo Cuesta-Vargas, Antonio I. J Pers Med Article The study’s purpose was to assess the reliability of the LIS2DH12 in two different positions, using the commercial sensor Actigraph GT9X as a reference instrument. Five participants completed two gait tests on a treadmill. Firstly, both sensors were worn on the wrist and around the thigh. Each test consisted of a 1 min walk for participants to become accustomed to the treadmill, followed by a 2 min trial at ten pre-set speeds. Data from both sensors were collected in real-time. Intraclass correlation coefficient (ICC) was used to evaluate the equality of characteristics obtained by both sensors: maximum peaks, minimum peaks, and the mean of the complete signal (sequence of acceleration values along the time) by each axis and speed were extracted to evaluate the equality of characteristics obtained with LIS2DH12 compared to Actigraph. Intraclass correlation coefficient (ICC) was extracted, and a standard deviation of the mean was obtained from the data. Our results show that LIS2DH12 measurements present more reliability than Actigraph GT9X, ICC > 0.8 at three axes. This study concludes that LIS2DH12 is as reliable and accurate as Actigraph GT9X Link and, therefore, would be a suitable tool for future kinematic studies. MDPI 2022-05-05 /pmc/articles/PMC9147434/ /pubmed/35629171 http://dx.doi.org/10.3390/jpm12050749 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Martín-Martín, Jaime
Jiménez-Partinen, Ariadna
De-Torres, Irene
Escriche-Escuder, Adrian
González-Sánchez, Manuel
Muro-Culebras, Antonio
Roldán-Jiménez, Cristina
Ruiz-Muñoz, María
Mayoral-Cleries, Fermín
Biró, Attila
Tang, Wen
Nikolova, Borjanka
Salvatore, Alfredo
Cuesta-Vargas, Antonio I.
Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title_full Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title_fullStr Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title_full_unstemmed Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title_short Reliability Study of Inertial Sensors LIS2DH12 Compared to ActiGraph GT9X: Based on Free Code
title_sort reliability study of inertial sensors lis2dh12 compared to actigraph gt9x: based on free code
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9147434/
https://www.ncbi.nlm.nih.gov/pubmed/35629171
http://dx.doi.org/10.3390/jpm12050749
work_keys_str_mv AT martinmartinjaime reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT jimenezpartinenariadna reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT detorresirene reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT escricheescuderadrian reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT gonzalezsanchezmanuel reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT muroculebrasantonio reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT roldanjimenezcristina reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT ruizmunozmaria reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT mayoralcleriesfermin reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT biroattila reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT tangwen reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT nikolovaborjanka reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT salvatorealfredo reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode
AT cuestavargasantonioi reliabilitystudyofinertialsensorslis2dh12comparedtoactigraphgt9xbasedonfreecode