Cargando…

The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour

Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressi...

Descripción completa

Detalles Bibliográficos
Autores principales: Callejas, Juan Antonio, Brizuela, Aritza, Ríos-Carrasco, Blanca, Gil, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9148149/
https://www.ncbi.nlm.nih.gov/pubmed/35629663
http://dx.doi.org/10.3390/ma15103636
_version_ 1784716981982724096
author Callejas, Juan Antonio
Brizuela, Aritza
Ríos-Carrasco, Blanca
Gil, Javier
author_facet Callejas, Juan Antonio
Brizuela, Aritza
Ríos-Carrasco, Blanca
Gil, Javier
author_sort Callejas, Juan Antonio
collection PubMed
description Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 μm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 μm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m(2)/g) corresponds to the particles larger than 30 μm being higher than 0.4969 and 0.4802 m(2)/g of those that are 5 and 15 μm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, −395 MPa for the 5 μm particles, and −369 for the 15 μm particles, and the lowest residual stresses were found for the 30 μm particles with values of −267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 μm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts.
format Online
Article
Text
id pubmed-9148149
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91481492022-05-29 The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour Callejas, Juan Antonio Brizuela, Aritza Ríos-Carrasco, Blanca Gil, Javier Materials (Basel) Article Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 μm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 μm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m(2)/g) corresponds to the particles larger than 30 μm being higher than 0.4969 and 0.4802 m(2)/g of those that are 5 and 15 μm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, −395 MPa for the 5 μm particles, and −369 for the 15 μm particles, and the lowest residual stresses were found for the 30 μm particles with values of −267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 μm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts. MDPI 2022-05-19 /pmc/articles/PMC9148149/ /pubmed/35629663 http://dx.doi.org/10.3390/ma15103636 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Callejas, Juan Antonio
Brizuela, Aritza
Ríos-Carrasco, Blanca
Gil, Javier
The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title_full The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title_fullStr The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title_full_unstemmed The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title_short The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour
title_sort characterization of titanium particles released from bone-level titanium dental implants: effect of the size of particles on the ion release and cytotoxicity behaviour
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9148149/
https://www.ncbi.nlm.nih.gov/pubmed/35629663
http://dx.doi.org/10.3390/ma15103636
work_keys_str_mv AT callejasjuanantonio thecharacterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT brizuelaaritza thecharacterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT rioscarrascoblanca thecharacterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT giljavier thecharacterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT callejasjuanantonio characterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT brizuelaaritza characterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT rioscarrascoblanca characterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour
AT giljavier characterizationoftitaniumparticlesreleasedfromboneleveltitaniumdentalimplantseffectofthesizeofparticlesontheionreleaseandcytotoxicitybehaviour