Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis

Aim The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. Methodology A mech...

Descripción completa

Detalles Bibliográficos
Autores principales: Ellendula, Yashaswini, Chandra Sekar, Anam, Nalla, Sandeep, Basany, Ram B, Sailasri, Kunchala, Thandu, Ashwini
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9148546/
https://www.ncbi.nlm.nih.gov/pubmed/35664406
http://dx.doi.org/10.7759/cureus.24591
_version_ 1784717056683278336
author Ellendula, Yashaswini
Chandra Sekar, Anam
Nalla, Sandeep
Basany, Ram B
Sailasri, Kunchala
Thandu, Ashwini
author_facet Ellendula, Yashaswini
Chandra Sekar, Anam
Nalla, Sandeep
Basany, Ram B
Sailasri, Kunchala
Thandu, Ashwini
author_sort Ellendula, Yashaswini
collection PubMed
description Aim The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. Methodology A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. Results On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Conclusion Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant.
format Online
Article
Text
id pubmed-9148546
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-91485462022-06-02 Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis Ellendula, Yashaswini Chandra Sekar, Anam Nalla, Sandeep Basany, Ram B Sailasri, Kunchala Thandu, Ashwini Cureus Dentistry Aim The aim of the study was to assess the effect of implant placement depth on stress distribution in bone around a platform-switched and Morse taper dental implants placed at the equi-crestal and 1 mm and 2 mm sub-crestal levels in a D3 bone using the 3D finite element analysis. Methodology A mechanical model of a partially edentulous maxilla was generated from a computerized tomography (CT) scan of an edentulous patient, as it can give exact bony contours of cortical bone. Also, from accurate geometric measurements obtained from the manufacturer, 3D models of Morse taper and platform-switched implants were manually drawn. The implant and bone models were then superimposed to simulate implant insertion in bone. Three implant positioning levels such as the equi-crestal, 1 mm sub-crestal, and 2 mm sub-crestal models were created, and meshing was done to create the number of elements for distribution of applying loads. The elastic properties of cortical bone and implant, such as Young's modulus and Poisson's ratio (µ), were determined. A load (axial and oblique) of 200N that simulated masticatory force was applied. Results On comparing stresses within the bone around the equi-crestal and 1 mm and 2 mm sub-crestal implants, it was observed that the maximum stresses were seen within cortical bone around the equi-crestally placed implant (21.694), the least in the 2 mm sub-crestally placed implant (18.85), and intermediate stresses were seen within the 1 mm sub-crestally placed implant (18.876). Conclusion Sub-crestal (1-2mm) placement of a Morse taper and a platform-switched implant is recommended for long-term success, as maximum von Mises stresses were found within cortical bone around the equi-crestal implant followed by the 1 mm sub-crestal implant and then the 2 mm sub-crestal implant. Cureus 2022-04-29 /pmc/articles/PMC9148546/ /pubmed/35664406 http://dx.doi.org/10.7759/cureus.24591 Text en Copyright © 2022, Ellendula et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Ellendula, Yashaswini
Chandra Sekar, Anam
Nalla, Sandeep
Basany, Ram B
Sailasri, Kunchala
Thandu, Ashwini
Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title_full Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title_fullStr Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title_full_unstemmed Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title_short Biomechanical Evaluation of Stress Distribution in Equicrestal and Sub-crestally Placed, Platform-Switched Morse Taper Dental Implants in D3 Bone: Finite Element Analysis
title_sort biomechanical evaluation of stress distribution in equicrestal and sub-crestally placed, platform-switched morse taper dental implants in d3 bone: finite element analysis
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9148546/
https://www.ncbi.nlm.nih.gov/pubmed/35664406
http://dx.doi.org/10.7759/cureus.24591
work_keys_str_mv AT ellendulayashaswini biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis
AT chandrasekaranam biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis
AT nallasandeep biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis
AT basanyramb biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis
AT sailasrikunchala biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis
AT thanduashwini biomechanicalevaluationofstressdistributioninequicrestalandsubcrestallyplacedplatformswitchedmorsetaperdentalimplantsind3bonefiniteelementanalysis