Cargando…

Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study

BACKGROUND: The head-elevated laryngoscopy position has been described to be optimal for intubation, particularly in obese patients and those with anticipated difficult airways. Horizontal alignment of the external auditory meatus and sternal notch (AM-S) can be used as endpoints for optimal positio...

Descripción completa

Detalles Bibliográficos
Autores principales: Chun, Eun Hee, Chung, Mi Hwa, Kim, Jung Eun, Kim, Kyung Mi, Lee, Hye Sun, Son, Jung Mo, Park, Jiho, Jun, Joo Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9150377/
https://www.ncbi.nlm.nih.gov/pubmed/35637437
http://dx.doi.org/10.1186/s12871-022-01706-5
_version_ 1784717403699019776
author Chun, Eun Hee
Chung, Mi Hwa
Kim, Jung Eun
Kim, Kyung Mi
Lee, Hye Sun
Son, Jung Mo
Park, Jiho
Jun, Joo Hyun
author_facet Chun, Eun Hee
Chung, Mi Hwa
Kim, Jung Eun
Kim, Kyung Mi
Lee, Hye Sun
Son, Jung Mo
Park, Jiho
Jun, Joo Hyun
author_sort Chun, Eun Hee
collection PubMed
description BACKGROUND: The head-elevated laryngoscopy position has been described to be optimal for intubation, particularly in obese patients and those with anticipated difficult airways. Horizontal alignment of the external auditory meatus and sternal notch (AM-S) can be used as endpoints for optimal positioning. Thus, we aligned the head-elevated position with the AM-S in the horizontal plane and evaluated its effect on laryngeal visualization and ease of intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway. METHODS: Sixty-four patients were included in this prospective, crossover, randomized controlled trial. A cervical collar was used to restrict neck movement and mouth opening. The head-elevated position was achieved by raising the back section of the operation room table and ensuring that the end point was horizontally aligned with the AM-S (table-ramp method). The laryngeal view was randomly assessed in both head-flat and head-elevated positions based on the percentage of glottic opening (POGO) score and modified Cormack–Lehane (MCL) grade. External laryngeal manipulation was not permitted when laryngeal visualization was scored. The trachea was intubated only once (in the second position). The ease of intubation was assessed based on the need for optimization maneuvers, intubation difficulty scale (IDS) scores and time to intubation. RESULTS: The mean table-ramp angle required to achieve the horizontal alignment of AM-S was 17.5 ± 4.1°. The mean POGO score improved significantly in the head-elevated position (59.4 ± 23.8%) when compared with the head-flat position (37.5 ± 24%) (P <  0.0001). MCL grade 1 or 2a was achieved in 56 (85.9%) and 28 (43.7%) of patients in the head-elevated and head-flat positions, respectively (P <  0.0001). Optimization maneuvers for intubation were required in 7 (21.9%) and 17 (53.1%) patients in the head-elevated and head-flat positions, respectively (P <  0.0001). The IDS scores and time to intubation did not differ significantly between the two positions. CONCLUSION: In the head-elevated position, aligning the AM-S in the horizontal plane consistently improved laryngeal visualization without worsening the view when the McGrath MAC videolaryngoscope was used in patients with simulated difficult airways. It also improved the ease of intubation, which reduced the need for optimization maneuvers. TRIAL REGISTRATION: This trial was registered with www.clinicaltrials.gov, NCT04716218, on 20/01/2021. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01706-5.
format Online
Article
Text
id pubmed-9150377
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91503772022-05-31 Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study Chun, Eun Hee Chung, Mi Hwa Kim, Jung Eun Kim, Kyung Mi Lee, Hye Sun Son, Jung Mo Park, Jiho Jun, Joo Hyun BMC Anesthesiol Research BACKGROUND: The head-elevated laryngoscopy position has been described to be optimal for intubation, particularly in obese patients and those with anticipated difficult airways. Horizontal alignment of the external auditory meatus and sternal notch (AM-S) can be used as endpoints for optimal positioning. Thus, we aligned the head-elevated position with the AM-S in the horizontal plane and evaluated its effect on laryngeal visualization and ease of intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway. METHODS: Sixty-four patients were included in this prospective, crossover, randomized controlled trial. A cervical collar was used to restrict neck movement and mouth opening. The head-elevated position was achieved by raising the back section of the operation room table and ensuring that the end point was horizontally aligned with the AM-S (table-ramp method). The laryngeal view was randomly assessed in both head-flat and head-elevated positions based on the percentage of glottic opening (POGO) score and modified Cormack–Lehane (MCL) grade. External laryngeal manipulation was not permitted when laryngeal visualization was scored. The trachea was intubated only once (in the second position). The ease of intubation was assessed based on the need for optimization maneuvers, intubation difficulty scale (IDS) scores and time to intubation. RESULTS: The mean table-ramp angle required to achieve the horizontal alignment of AM-S was 17.5 ± 4.1°. The mean POGO score improved significantly in the head-elevated position (59.4 ± 23.8%) when compared with the head-flat position (37.5 ± 24%) (P <  0.0001). MCL grade 1 or 2a was achieved in 56 (85.9%) and 28 (43.7%) of patients in the head-elevated and head-flat positions, respectively (P <  0.0001). Optimization maneuvers for intubation were required in 7 (21.9%) and 17 (53.1%) patients in the head-elevated and head-flat positions, respectively (P <  0.0001). The IDS scores and time to intubation did not differ significantly between the two positions. CONCLUSION: In the head-elevated position, aligning the AM-S in the horizontal plane consistently improved laryngeal visualization without worsening the view when the McGrath MAC videolaryngoscope was used in patients with simulated difficult airways. It also improved the ease of intubation, which reduced the need for optimization maneuvers. TRIAL REGISTRATION: This trial was registered with www.clinicaltrials.gov, NCT04716218, on 20/01/2021. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-022-01706-5. BioMed Central 2022-05-30 /pmc/articles/PMC9150377/ /pubmed/35637437 http://dx.doi.org/10.1186/s12871-022-01706-5 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chun, Eun Hee
Chung, Mi Hwa
Kim, Jung Eun
Kim, Kyung Mi
Lee, Hye Sun
Son, Jung Mo
Park, Jiho
Jun, Joo Hyun
Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title_full Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title_fullStr Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title_full_unstemmed Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title_short Effects of head-elevated position on tracheal intubation using a McGrath MAC videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
title_sort effects of head-elevated position on tracheal intubation using a mcgrath mac videolaryngoscope in patients with a simulated difficult airway: a prospective randomized crossover study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9150377/
https://www.ncbi.nlm.nih.gov/pubmed/35637437
http://dx.doi.org/10.1186/s12871-022-01706-5
work_keys_str_mv AT chuneunhee effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT chungmihwa effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT kimjungeun effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT kimkyungmi effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT leehyesun effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT sonjungmo effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT parkjiho effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy
AT junjoohyun effectsofheadelevatedpositionontrachealintubationusingamcgrathmacvideolaryngoscopeinpatientswithasimulateddifficultairwayaprospectiverandomizedcrossoverstudy