Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry
INTRODUCTION: In the context of randomized clinical trials, subcutaneous implantable cardiac defibrillators (S-ICDs) are non-inferior to transvenous ICDs (T-ICDs) concerning device-related complications or inappropriate shocks in patients with an indication for defibrillator therapy and not in need...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9150501/ https://www.ncbi.nlm.nih.gov/pubmed/35651910 http://dx.doi.org/10.3389/fcvm.2022.879918 |
_version_ | 1784717413880692736 |
---|---|
author | Russo, Vincenzo Rago, Anna Ruggiero, Vincenzo Cavaliere, Francesca Bianchi, Valter Ammendola, Ernesto Papa, Andrea Antonio Tavoletta, Vincenzo De Vivo, Stefano Golino, Paolo D'Onofrio, Antonio Nigro, Gerardo |
author_facet | Russo, Vincenzo Rago, Anna Ruggiero, Vincenzo Cavaliere, Francesca Bianchi, Valter Ammendola, Ernesto Papa, Andrea Antonio Tavoletta, Vincenzo De Vivo, Stefano Golino, Paolo D'Onofrio, Antonio Nigro, Gerardo |
author_sort | Russo, Vincenzo |
collection | PubMed |
description | INTRODUCTION: In the context of randomized clinical trials, subcutaneous implantable cardiac defibrillators (S-ICDs) are non-inferior to transvenous ICDs (T-ICDs) concerning device-related complications or inappropriate shocks in patients with an indication for defibrillator therapy and not in need of pacing. We aimed at describing the clinical features of patients who underwent S-ICD implantation in our clinical practice, as well as the ICD-related complications and the inappropriate therapies among S-ICD vs. T-ICD recipients during a long-term follow-up. MATERIALS AND METHODS: All patients undergoing ICD, both S-ICD and TV-ICD, at Monaldi Hospital from January 1, 2015 to January 1, 2019 and followed up at our institution were included in the present analysis. The clinical variables associated with S-ICD implantation were evaluated by logistic regression analyses. We collected the ICD inappropriate therapies, ICD-related complications (including both pulse generator and lead-related complications), ICD-related infections, appropriate ICD therapies, and overall mortality. Kaplan-Meier (KM) analyses were performed to assess the risk of clinical outcome events between the two subgroups. A time-dependent Cox regression analysis was performed to adjust the results. RESULTS: Total 607 consecutive patients (mean age 53.8 ± 16.8, male 77.8%) with both TV-ICD (n: 290, 47.8%) and S-ICD (n: 317, 52.2%), implanted and followed at our center for a mean follow-up of 1614 ± 1018 days, were included in the study. At multivariate logistic regression analysis, an independent association between S-ICD implantation and ionic channel disease [OR: 6.01 (2.26–15.87); p < 0.0001] and ischemic cardiomyopathy [OR: 0.20 (0.12–0.35); p < 0.0001] was shown. The KM analysis did not show a significantly different risk of the inappropriate ICD therapies (log rank p = 0.64) between the two subgroups; conversely, a significant increase in the risk of ICD-related complications (log rank p = 0.02) and infections (log rank p = 0.02) in TV-ICD group was shown. The adjusted risk for ICD-related infections [OR: 0.07 (0.009–0.55), p = 0.01] and complications [0.31 (0.12–0.81), p = 0.01] was significantly lower among patients with S-ICD. CONCLUSIONS: The choice to implant S-ICD was mainly driven by younger age and the presence of ionic channel disease; conversely ischemic cardiomyopathy reduces the probability to use this technology. No significant differences in inappropriate ICD therapies were shown among S-ICD vs. TV-ICD group; moreover, S-ICD is characterized by a lower rate of infectious and non-infectious complications leading to surgical revision or extraction. |
format | Online Article Text |
id | pubmed-9150501 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-91505012022-05-31 Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry Russo, Vincenzo Rago, Anna Ruggiero, Vincenzo Cavaliere, Francesca Bianchi, Valter Ammendola, Ernesto Papa, Andrea Antonio Tavoletta, Vincenzo De Vivo, Stefano Golino, Paolo D'Onofrio, Antonio Nigro, Gerardo Front Cardiovasc Med Cardiovascular Medicine INTRODUCTION: In the context of randomized clinical trials, subcutaneous implantable cardiac defibrillators (S-ICDs) are non-inferior to transvenous ICDs (T-ICDs) concerning device-related complications or inappropriate shocks in patients with an indication for defibrillator therapy and not in need of pacing. We aimed at describing the clinical features of patients who underwent S-ICD implantation in our clinical practice, as well as the ICD-related complications and the inappropriate therapies among S-ICD vs. T-ICD recipients during a long-term follow-up. MATERIALS AND METHODS: All patients undergoing ICD, both S-ICD and TV-ICD, at Monaldi Hospital from January 1, 2015 to January 1, 2019 and followed up at our institution were included in the present analysis. The clinical variables associated with S-ICD implantation were evaluated by logistic regression analyses. We collected the ICD inappropriate therapies, ICD-related complications (including both pulse generator and lead-related complications), ICD-related infections, appropriate ICD therapies, and overall mortality. Kaplan-Meier (KM) analyses were performed to assess the risk of clinical outcome events between the two subgroups. A time-dependent Cox regression analysis was performed to adjust the results. RESULTS: Total 607 consecutive patients (mean age 53.8 ± 16.8, male 77.8%) with both TV-ICD (n: 290, 47.8%) and S-ICD (n: 317, 52.2%), implanted and followed at our center for a mean follow-up of 1614 ± 1018 days, were included in the study. At multivariate logistic regression analysis, an independent association between S-ICD implantation and ionic channel disease [OR: 6.01 (2.26–15.87); p < 0.0001] and ischemic cardiomyopathy [OR: 0.20 (0.12–0.35); p < 0.0001] was shown. The KM analysis did not show a significantly different risk of the inappropriate ICD therapies (log rank p = 0.64) between the two subgroups; conversely, a significant increase in the risk of ICD-related complications (log rank p = 0.02) and infections (log rank p = 0.02) in TV-ICD group was shown. The adjusted risk for ICD-related infections [OR: 0.07 (0.009–0.55), p = 0.01] and complications [0.31 (0.12–0.81), p = 0.01] was significantly lower among patients with S-ICD. CONCLUSIONS: The choice to implant S-ICD was mainly driven by younger age and the presence of ionic channel disease; conversely ischemic cardiomyopathy reduces the probability to use this technology. No significant differences in inappropriate ICD therapies were shown among S-ICD vs. TV-ICD group; moreover, S-ICD is characterized by a lower rate of infectious and non-infectious complications leading to surgical revision or extraction. Frontiers Media S.A. 2022-05-16 /pmc/articles/PMC9150501/ /pubmed/35651910 http://dx.doi.org/10.3389/fcvm.2022.879918 Text en Copyright © 2022 Russo, Rago, Ruggiero, Cavaliere, Bianchi, Ammendola, Papa, Tavoletta, De Vivo, Golino, D'Onofrio and Nigro. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Russo, Vincenzo Rago, Anna Ruggiero, Vincenzo Cavaliere, Francesca Bianchi, Valter Ammendola, Ernesto Papa, Andrea Antonio Tavoletta, Vincenzo De Vivo, Stefano Golino, Paolo D'Onofrio, Antonio Nigro, Gerardo Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title | Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title_full | Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title_fullStr | Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title_full_unstemmed | Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title_short | Device-Related Complications and Inappropriate Therapies Among Subcutaneous vs. Transvenous Implantable Defibrillator Recipients: Insight Monaldi Rhythm Registry |
title_sort | device-related complications and inappropriate therapies among subcutaneous vs. transvenous implantable defibrillator recipients: insight monaldi rhythm registry |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9150501/ https://www.ncbi.nlm.nih.gov/pubmed/35651910 http://dx.doi.org/10.3389/fcvm.2022.879918 |
work_keys_str_mv | AT russovincenzo devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT ragoanna devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT ruggierovincenzo devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT cavalierefrancesca devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT bianchivalter devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT ammendolaernesto devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT papaandreaantonio devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT tavolettavincenzo devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT devivostefano devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT golinopaolo devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT donofrioantonio devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry AT nigrogerardo devicerelatedcomplicationsandinappropriatetherapiesamongsubcutaneousvstransvenousimplantabledefibrillatorrecipientsinsightmonaldirhythmregistry |