Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure
OBJECTIVE: The objective of this study is to present our experience using the pressure-regulated volume control and the pressure-control ventilation modes in children. METHODS: Patients with acute respiratory failure ventilated with pressure-regulated volume control or pressure-control modes were re...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Turkish Society of Anaesthesiology and Reanimation
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9153944/ https://www.ncbi.nlm.nih.gov/pubmed/35256341 http://dx.doi.org/10.5152/TJAR.2021.1412 |
_version_ | 1784717939702759424 |
---|---|
author | Serdar Kıhtır, Hasan Akçay, Nihal Şevketoğlu, Esra |
author_facet | Serdar Kıhtır, Hasan Akçay, Nihal Şevketoğlu, Esra |
author_sort | Serdar Kıhtır, Hasan |
collection | PubMed |
description | OBJECTIVE: The objective of this study is to present our experience using the pressure-regulated volume control and the pressure-control ventilation modes in children. METHODS: Patients with acute respiratory failure ventilated with pressure-regulated volume control or pressure-control modes were retrospectively evaluated. The patient’s ventilation parameters (of the first 7 days of ventilation or of the whole ventilation period, if the patient had been ventilated less than 7 days), SpO(2), blood gases, and demographic data were collected from the pediatric intensive care unit database. RESULTS: Sixty-one patients (median age 12 [4.8-36.4] months) were enrolled in the study. The pressure-control ventilation mode was used on 40 patients (65.6%) and the pressure-regulated volume-control mode was used on 21 (34.4%) patients. Twenty-eight patients (45.9%) had hypoxemic respiratory failure and 44 (72.1%) had hypercapnic respiratory failure. The median positive end-expiratory pressure was higher in pressure-control ventilation mode (5.4 [4.2-6.3] cmH(2)O) than the pressure-regulated volume-control mode (4.05 [3.68-4.41] H(2)O, P < .001). Pressure-control mode was used more frequently in hypoxemic cases but both modes were used equally in hypercapnic cases. Hypoxic respiratory failure (yes/no), odds ratio: 3.9 (95% CI 1.2-12.3, P = .02), Ph (nadir), odds ratio: 0.004 (95% CI 0.000-0.275, P = .01), and base excess, odds ratio: 0.88 (95% CI 0.79-0.98, P = .02) were associated with intensive care mortality. CONCLUSIONS: Although the pressure-control ventilation mode was preferred more frequently in hypoxemic respiratory failure, there was no significant difference between the 2 respiratory modes in terms of length of pediatric intensive care unit stay, MV duration, and mortality. The pressure-regulated volume-control mode seems to be a safer option for physicians who do not have enough experience in using pressure-control ventilation mode. |
format | Online Article Text |
id | pubmed-9153944 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Turkish Society of Anaesthesiology and Reanimation |
record_format | MEDLINE/PubMed |
spelling | pubmed-91539442022-06-16 Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure Serdar Kıhtır, Hasan Akçay, Nihal Şevketoğlu, Esra Turk J Anaesthesiol Reanim Original Article Intensive Care OBJECTIVE: The objective of this study is to present our experience using the pressure-regulated volume control and the pressure-control ventilation modes in children. METHODS: Patients with acute respiratory failure ventilated with pressure-regulated volume control or pressure-control modes were retrospectively evaluated. The patient’s ventilation parameters (of the first 7 days of ventilation or of the whole ventilation period, if the patient had been ventilated less than 7 days), SpO(2), blood gases, and demographic data were collected from the pediatric intensive care unit database. RESULTS: Sixty-one patients (median age 12 [4.8-36.4] months) were enrolled in the study. The pressure-control ventilation mode was used on 40 patients (65.6%) and the pressure-regulated volume-control mode was used on 21 (34.4%) patients. Twenty-eight patients (45.9%) had hypoxemic respiratory failure and 44 (72.1%) had hypercapnic respiratory failure. The median positive end-expiratory pressure was higher in pressure-control ventilation mode (5.4 [4.2-6.3] cmH(2)O) than the pressure-regulated volume-control mode (4.05 [3.68-4.41] H(2)O, P < .001). Pressure-control mode was used more frequently in hypoxemic cases but both modes were used equally in hypercapnic cases. Hypoxic respiratory failure (yes/no), odds ratio: 3.9 (95% CI 1.2-12.3, P = .02), Ph (nadir), odds ratio: 0.004 (95% CI 0.000-0.275, P = .01), and base excess, odds ratio: 0.88 (95% CI 0.79-0.98, P = .02) were associated with intensive care mortality. CONCLUSIONS: Although the pressure-control ventilation mode was preferred more frequently in hypoxemic respiratory failure, there was no significant difference between the 2 respiratory modes in terms of length of pediatric intensive care unit stay, MV duration, and mortality. The pressure-regulated volume-control mode seems to be a safer option for physicians who do not have enough experience in using pressure-control ventilation mode. Turkish Society of Anaesthesiology and Reanimation 2022-02-01 /pmc/articles/PMC9153944/ /pubmed/35256341 http://dx.doi.org/10.5152/TJAR.2021.1412 Text en © Copyright 2022 authors https://creativecommons.org/licenses/by/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by/4.0/) |
spellingShingle | Original Article Intensive Care Serdar Kıhtır, Hasan Akçay, Nihal Şevketoğlu, Esra Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title | Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title_full | Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title_fullStr | Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title_full_unstemmed | Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title_short | Pressure-Regulated Volume Control and Pressure-Control Ventilation Modes in Pediatric Acute Respiratory Failure |
title_sort | pressure-regulated volume control and pressure-control ventilation modes in pediatric acute respiratory failure |
topic | Original Article Intensive Care |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9153944/ https://www.ncbi.nlm.nih.gov/pubmed/35256341 http://dx.doi.org/10.5152/TJAR.2021.1412 |
work_keys_str_mv | AT serdarkıhtırhasan pressureregulatedvolumecontrolandpressurecontrolventilationmodesinpediatricacuterespiratoryfailure AT akcaynihal pressureregulatedvolumecontrolandpressurecontrolventilationmodesinpediatricacuterespiratoryfailure AT sevketogluesra pressureregulatedvolumecontrolandpressurecontrolventilationmodesinpediatricacuterespiratoryfailure |