Cargando…
Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent
A novel extraction procedure was developed using polystyrene (PS) nanofibers as a solid-phase extraction sorbent to collect atypical antipsychotics (AAPs) from human plasma. The extraction targets were then monitored by ultra high performance liquid chromatography with an ultraviolet detector system...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Royal Society of Chemistry
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9155176/ https://www.ncbi.nlm.nih.gov/pubmed/35733678 http://dx.doi.org/10.1039/d2ra02457h |
_version_ | 1784718186519724032 |
---|---|
author | Fan, Liju An, Jing Gao, Jin Cui, Yanjun Dong, Zhanjun |
author_facet | Fan, Liju An, Jing Gao, Jin Cui, Yanjun Dong, Zhanjun |
author_sort | Fan, Liju |
collection | PubMed |
description | A novel extraction procedure was developed using polystyrene (PS) nanofibers as a solid-phase extraction sorbent to collect atypical antipsychotics (AAPs) from human plasma. The extraction targets were then monitored by ultra high performance liquid chromatography with an ultraviolet detector system. Parameters affecting extraction efficiency such as fiber packing amount, wash solution, and eluted solvent were investigated. Under optimized conditions, the linear range of seven AAPs was 1–50 μgmL(−1) (R(2) > 0.996). Inter-day and intra-day relative standard deviations were less than 15.1%, and relative error varied from −17.1% to 12.0%. Furthermore, 50.5–79.3% extraction recoveries were obtained. The lower limit of quantification was 1 μg mL(−1), and detection limit was 0.5 μg mL(−1). The method developed in this study may be applied to simultaneous quantification of seven AAPs in human plasma due to its simplicity, selectivity, and efficiency. |
format | Online Article Text |
id | pubmed-9155176 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-91551762022-06-21 Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent Fan, Liju An, Jing Gao, Jin Cui, Yanjun Dong, Zhanjun RSC Adv Chemistry A novel extraction procedure was developed using polystyrene (PS) nanofibers as a solid-phase extraction sorbent to collect atypical antipsychotics (AAPs) from human plasma. The extraction targets were then monitored by ultra high performance liquid chromatography with an ultraviolet detector system. Parameters affecting extraction efficiency such as fiber packing amount, wash solution, and eluted solvent were investigated. Under optimized conditions, the linear range of seven AAPs was 1–50 μgmL(−1) (R(2) > 0.996). Inter-day and intra-day relative standard deviations were less than 15.1%, and relative error varied from −17.1% to 12.0%. Furthermore, 50.5–79.3% extraction recoveries were obtained. The lower limit of quantification was 1 μg mL(−1), and detection limit was 0.5 μg mL(−1). The method developed in this study may be applied to simultaneous quantification of seven AAPs in human plasma due to its simplicity, selectivity, and efficiency. The Royal Society of Chemistry 2022-05-31 /pmc/articles/PMC9155176/ /pubmed/35733678 http://dx.doi.org/10.1039/d2ra02457h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/ |
spellingShingle | Chemistry Fan, Liju An, Jing Gao, Jin Cui, Yanjun Dong, Zhanjun Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title | Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title_full | Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title_fullStr | Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title_full_unstemmed | Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title_short | Determination of atypical antipsychotics in human plasma by UPLC-UV with polystyrene nanofibers as a solid-phase extraction sorbent |
title_sort | determination of atypical antipsychotics in human plasma by uplc-uv with polystyrene nanofibers as a solid-phase extraction sorbent |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9155176/ https://www.ncbi.nlm.nih.gov/pubmed/35733678 http://dx.doi.org/10.1039/d2ra02457h |
work_keys_str_mv | AT fanliju determinationofatypicalantipsychoticsinhumanplasmabyuplcuvwithpolystyrenenanofibersasasolidphaseextractionsorbent AT anjing determinationofatypicalantipsychoticsinhumanplasmabyuplcuvwithpolystyrenenanofibersasasolidphaseextractionsorbent AT gaojin determinationofatypicalantipsychoticsinhumanplasmabyuplcuvwithpolystyrenenanofibersasasolidphaseextractionsorbent AT cuiyanjun determinationofatypicalantipsychoticsinhumanplasmabyuplcuvwithpolystyrenenanofibersasasolidphaseextractionsorbent AT dongzhanjun determinationofatypicalantipsychoticsinhumanplasmabyuplcuvwithpolystyrenenanofibersasasolidphaseextractionsorbent |