Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function

OBJECTIVE: To explore the value of color Doppler echocardiography (CDE) combined with serum heart-type fatty acid-binding protein (h-FABP) and cardiac troponin I (cTnI) in the diagnosis of myocardial infarction and its evaluation value in left ventricular function. METHODS: A total of 44 patients wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Miao, Yanling, Liu, Ying, Liu, Chao, Yao, Lei, Kang, Xiaoning, Lv, Maoting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9155908/
https://www.ncbi.nlm.nih.gov/pubmed/35656464
http://dx.doi.org/10.1155/2022/8809708
_version_ 1784718336924319744
author Miao, Yanling
Liu, Ying
Liu, Chao
Yao, Lei
Kang, Xiaoning
Lv, Maoting
author_facet Miao, Yanling
Liu, Ying
Liu, Chao
Yao, Lei
Kang, Xiaoning
Lv, Maoting
author_sort Miao, Yanling
collection PubMed
description OBJECTIVE: To explore the value of color Doppler echocardiography (CDE) combined with serum heart-type fatty acid-binding protein (h-FABP) and cardiac troponin I (cTnI) in the diagnosis of myocardial infarction and its evaluation value in left ventricular function. METHODS: A total of 44 patients with myocardial infarction who were treated in Cangzhou Central Hospital from October 2018 to February 2020 were included in the observation group, and 45 healthy subjects were included in the control group. The serum h-FABP and cTnI levels of the two groups were compared and analyzed. The coincidence rate of echocardiography plus serum h-FABP and cTnI for single diagnosis and combined diagnosis was analyzed. The left ventricular function indexes of patients with myocardial infarction in different cardiac function grades were compared, including left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), stroke volume (SV), cardiac index (CI), and the ratio of peak velocity blood flow from left ventricular relaxation in early diastole to peak velocity flow in late diastole (E/A). The value of echocardiography combined with serum h-FABP and cTnI in the left ventricular function in patients with myocardial infarction was analyzed. RESULTS: The levels of serum h-FABP and cTnI in the observation group were significantly higher than those in the control group (P < 0.05). CDE plus serum h-FABP and cTnI was associated with significantly higher sensitivity, specificity, and accuracy in diagnosing myocardial infarction versus single detection (P < 0.05). The LVEDV, SV, and CI parameters were similar in patients with different cardiac function grades (P > 0.05). Compared with cardiac function grades I and II, the level of LVEF in patients with myocardial infarction in grades III and IV of cardiac function decreased, while the levels of LVEDD, LVESD, LVESV, and E/A increased (P < 0.05). The levels of serum h-FABP and cTnI in patients with myocardial infarction increased with the increase of cardiac function grades (P < 0.05). CONCLUSION: Patients with myocardial infarction show high levels of h-FABP and cTnI, and CDE plus the detection of serum h-FABP and cTnI levels can significantly improve the detection accuracy and effectively evaluate the left ventricular function of patients with myocardial infarction, with a certain predictive value for cardiac function grading in myocardial infarction.
format Online
Article
Text
id pubmed-9155908
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91559082022-06-01 Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function Miao, Yanling Liu, Ying Liu, Chao Yao, Lei Kang, Xiaoning Lv, Maoting Evid Based Complement Alternat Med Research Article OBJECTIVE: To explore the value of color Doppler echocardiography (CDE) combined with serum heart-type fatty acid-binding protein (h-FABP) and cardiac troponin I (cTnI) in the diagnosis of myocardial infarction and its evaluation value in left ventricular function. METHODS: A total of 44 patients with myocardial infarction who were treated in Cangzhou Central Hospital from October 2018 to February 2020 were included in the observation group, and 45 healthy subjects were included in the control group. The serum h-FABP and cTnI levels of the two groups were compared and analyzed. The coincidence rate of echocardiography plus serum h-FABP and cTnI for single diagnosis and combined diagnosis was analyzed. The left ventricular function indexes of patients with myocardial infarction in different cardiac function grades were compared, including left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), stroke volume (SV), cardiac index (CI), and the ratio of peak velocity blood flow from left ventricular relaxation in early diastole to peak velocity flow in late diastole (E/A). The value of echocardiography combined with serum h-FABP and cTnI in the left ventricular function in patients with myocardial infarction was analyzed. RESULTS: The levels of serum h-FABP and cTnI in the observation group were significantly higher than those in the control group (P < 0.05). CDE plus serum h-FABP and cTnI was associated with significantly higher sensitivity, specificity, and accuracy in diagnosing myocardial infarction versus single detection (P < 0.05). The LVEDV, SV, and CI parameters were similar in patients with different cardiac function grades (P > 0.05). Compared with cardiac function grades I and II, the level of LVEF in patients with myocardial infarction in grades III and IV of cardiac function decreased, while the levels of LVEDD, LVESD, LVESV, and E/A increased (P < 0.05). The levels of serum h-FABP and cTnI in patients with myocardial infarction increased with the increase of cardiac function grades (P < 0.05). CONCLUSION: Patients with myocardial infarction show high levels of h-FABP and cTnI, and CDE plus the detection of serum h-FABP and cTnI levels can significantly improve the detection accuracy and effectively evaluate the left ventricular function of patients with myocardial infarction, with a certain predictive value for cardiac function grading in myocardial infarction. Hindawi 2022-05-24 /pmc/articles/PMC9155908/ /pubmed/35656464 http://dx.doi.org/10.1155/2022/8809708 Text en Copyright © 2022 Yanling Miao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Miao, Yanling
Liu, Ying
Liu, Chao
Yao, Lei
Kang, Xiaoning
Lv, Maoting
Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title_full Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title_fullStr Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title_full_unstemmed Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title_short Diagnostic Value of Echocardiography Combined with Serum h-FABP and cTnI in Myocardial Infarction and Its Evaluation Value in Left Ventricular Function
title_sort diagnostic value of echocardiography combined with serum h-fabp and ctni in myocardial infarction and its evaluation value in left ventricular function
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9155908/
https://www.ncbi.nlm.nih.gov/pubmed/35656464
http://dx.doi.org/10.1155/2022/8809708
work_keys_str_mv AT miaoyanling diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction
AT liuying diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction
AT liuchao diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction
AT yaolei diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction
AT kangxiaoning diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction
AT lvmaoting diagnosticvalueofechocardiographycombinedwithserumhfabpandctniinmyocardialinfarctionanditsevaluationvalueinleftventricularfunction