Cargando…
Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report
Hoffa fracture is a general term for single condylar or double condylar coronal fractures of the distal femur. It is a rare intra-articular fracture. At present, there is no specific fixation method for such fractures. The traditional method to fix Hoffa fracture mainly includes cannulated screws, h...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9157014/ https://www.ncbi.nlm.nih.gov/pubmed/35665196 http://dx.doi.org/10.1016/j.tcr.2022.100656 |
_version_ | 1784718557236428800 |
---|---|
author | Pei, Xuan Zheng, Yifan Zhou, Wei Wang, Guodong Liu, Ximing |
author_facet | Pei, Xuan Zheng, Yifan Zhou, Wei Wang, Guodong Liu, Ximing |
author_sort | Pei, Xuan |
collection | PubMed |
description | Hoffa fracture is a general term for single condylar or double condylar coronal fractures of the distal femur. It is a rare intra-articular fracture. At present, there is no specific fixation method for such fractures. The traditional method to fix Hoffa fracture mainly includes cannulated screws, however, failures of this type of internal fixation have been reported from time to time. Therefore, many scholars have proposed a more solid internal fixation that used cannulated screws combined with a buttress plate or lateral plate to treat this type of fracture, which has been widely recognized. Currently, there is no specially designed anatomical plate for lateral fixation of comminuted Hoffa fractures. In this report, we demonstrate a comminuted Hoffa fracture fixed by cannulated screws combined with a calcaneal reticular plate. The patient was followed up for 14 months. The knee joint ROM was 0– 120°, and the KSS score was 90 at the last follow-up. The efficacy was excellent according to the evaluation of Letenneur function. There was no pain after the activity and recovered to the pre-injury movement and exercise ability. |
format | Online Article Text |
id | pubmed-9157014 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-91570142022-06-02 Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report Pei, Xuan Zheng, Yifan Zhou, Wei Wang, Guodong Liu, Ximing Trauma Case Rep Case Report Hoffa fracture is a general term for single condylar or double condylar coronal fractures of the distal femur. It is a rare intra-articular fracture. At present, there is no specific fixation method for such fractures. The traditional method to fix Hoffa fracture mainly includes cannulated screws, however, failures of this type of internal fixation have been reported from time to time. Therefore, many scholars have proposed a more solid internal fixation that used cannulated screws combined with a buttress plate or lateral plate to treat this type of fracture, which has been widely recognized. Currently, there is no specially designed anatomical plate for lateral fixation of comminuted Hoffa fractures. In this report, we demonstrate a comminuted Hoffa fracture fixed by cannulated screws combined with a calcaneal reticular plate. The patient was followed up for 14 months. The knee joint ROM was 0– 120°, and the KSS score was 90 at the last follow-up. The efficacy was excellent according to the evaluation of Letenneur function. There was no pain after the activity and recovered to the pre-injury movement and exercise ability. Elsevier 2022-05-25 /pmc/articles/PMC9157014/ /pubmed/35665196 http://dx.doi.org/10.1016/j.tcr.2022.100656 Text en © 2022 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Pei, Xuan Zheng, Yifan Zhou, Wei Wang, Guodong Liu, Ximing Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title | Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title_full | Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title_fullStr | Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title_full_unstemmed | Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title_short | Calcaneal reticular plate with cannulated screws fixation for comminuted Hoffa fracture: A case report |
title_sort | calcaneal reticular plate with cannulated screws fixation for comminuted hoffa fracture: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9157014/ https://www.ncbi.nlm.nih.gov/pubmed/35665196 http://dx.doi.org/10.1016/j.tcr.2022.100656 |
work_keys_str_mv | AT peixuan calcanealreticularplatewithcannulatedscrewsfixationforcomminutedhoffafractureacasereport AT zhengyifan calcanealreticularplatewithcannulatedscrewsfixationforcomminutedhoffafractureacasereport AT zhouwei calcanealreticularplatewithcannulatedscrewsfixationforcomminutedhoffafractureacasereport AT wangguodong calcanealreticularplatewithcannulatedscrewsfixationforcomminutedhoffafractureacasereport AT liuximing calcanealreticularplatewithcannulatedscrewsfixationforcomminutedhoffafractureacasereport |