Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy

OBJECTIVE: The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. METHODS: This prospective study included 102 patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Zhiying, Wang, Fenglei, Dong, Fang, Li, Na, Wang, Dabo, Wang, Ling
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9159221/
https://www.ncbi.nlm.nih.gov/pubmed/35685518
http://dx.doi.org/10.1155/2022/7599631
_version_ 1784719009871036416
author Yu, Zhiying
Wang, Fenglei
Dong, Fang
Li, Na
Wang, Dabo
Wang, Ling
author_facet Yu, Zhiying
Wang, Fenglei
Dong, Fang
Li, Na
Wang, Dabo
Wang, Ling
author_sort Yu, Zhiying
collection PubMed
description OBJECTIVE: The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. METHODS: This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS-OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris-lens contact distance (ILCD) and iris-lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired-sample t-test was used to compare ACD, ILCD, and ILA measurements of the two methods, while Pearson's linear correlation and Bland-Altman analyses were used to analyze the correlation and consistency of the two results. RESULTS: The horizontal (2.499 ± 0.464 mm) and vertical (2.531 ± 0.463 mm) ACD measured using AS-OCT and the horizontal (2.556 ± 0.467 mm) and vertical (2.563 ± 0.479 mm) ACD measured using UBM were significantly different (P < 0.001); moreover, the results showed good correlation and agreement. A significant difference was observed between the two methods in terms of ILCD measured in inferior, superior, nasal, and temporal quadrants (P < 0.001), and a significant correlation was found between measurements of both methods (P < 0.001). Approximately 3.92% (4/102), 0.98% (1/102), 3.92% (4/102), and 2.94% (3/102) of points were outside the 95% limits of agreement in the four quadrants, respectively, and the agreement of the results was good. ILA measured using both methods differed in inferior, superior, nasal, and temporal quadrants (P=0.003, 0.011, 0.001, 0.001, respectively), and the correlation was good (P < 0.001). The percentage of points outside the 95% limit was higher in inferior, superior, nasal, and temporal quadrants (4.90% (5/102), 5.88% (6/102), 5.88% (6/102), and 6.86% (7/102)) with poor agreement of the results. CONCLUSIONS: The correlation between AS-OCT and UBM in terms of measuring lens position-related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and/or measurement methods (optics and ultrasound) may lead to variability in results.
format Online
Article
Text
id pubmed-9159221
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91592212022-06-07 Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy Yu, Zhiying Wang, Fenglei Dong, Fang Li, Na Wang, Dabo Wang, Ling Int J Clin Pract Research Article OBJECTIVE: The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. METHODS: This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS-OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris-lens contact distance (ILCD) and iris-lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired-sample t-test was used to compare ACD, ILCD, and ILA measurements of the two methods, while Pearson's linear correlation and Bland-Altman analyses were used to analyze the correlation and consistency of the two results. RESULTS: The horizontal (2.499 ± 0.464 mm) and vertical (2.531 ± 0.463 mm) ACD measured using AS-OCT and the horizontal (2.556 ± 0.467 mm) and vertical (2.563 ± 0.479 mm) ACD measured using UBM were significantly different (P < 0.001); moreover, the results showed good correlation and agreement. A significant difference was observed between the two methods in terms of ILCD measured in inferior, superior, nasal, and temporal quadrants (P < 0.001), and a significant correlation was found between measurements of both methods (P < 0.001). Approximately 3.92% (4/102), 0.98% (1/102), 3.92% (4/102), and 2.94% (3/102) of points were outside the 95% limits of agreement in the four quadrants, respectively, and the agreement of the results was good. ILA measured using both methods differed in inferior, superior, nasal, and temporal quadrants (P=0.003, 0.011, 0.001, 0.001, respectively), and the correlation was good (P < 0.001). The percentage of points outside the 95% limit was higher in inferior, superior, nasal, and temporal quadrants (4.90% (5/102), 5.88% (6/102), 5.88% (6/102), and 6.86% (7/102)) with poor agreement of the results. CONCLUSIONS: The correlation between AS-OCT and UBM in terms of measuring lens position-related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and/or measurement methods (optics and ultrasound) may lead to variability in results. Hindawi 2022-03-20 /pmc/articles/PMC9159221/ /pubmed/35685518 http://dx.doi.org/10.1155/2022/7599631 Text en Copyright © 2022 Zhiying Yu et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yu, Zhiying
Wang, Fenglei
Dong, Fang
Li, Na
Wang, Dabo
Wang, Ling
Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title_full Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title_fullStr Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title_full_unstemmed Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title_short Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy
title_sort comparison of ocular morphological parameters related to lens position by anterior segment optical coherence tomography and ultrasound biomicroscopy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9159221/
https://www.ncbi.nlm.nih.gov/pubmed/35685518
http://dx.doi.org/10.1155/2022/7599631
work_keys_str_mv AT yuzhiying comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT wangfenglei comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT dongfang comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT lina comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT wangdabo comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy
AT wangling comparisonofocularmorphologicalparametersrelatedtolenspositionbyanteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopy