Cargando…

Long-term follow-up of thoracoscopic ablation in long-standing persistent atrial fibrillation

OBJECTIVES: Catheter ablation of long-standing persistent atrial fibrillation (LSPAF) remains challenging, with suboptimal success rates obtained following multiple procedures. Thoracoscopic ablation has shown effective at creating transmural lesions around the pulmonary veins and box; however, long...

Descripción completa

Detalles Bibliográficos
Autores principales: Harlaar, Niels, Oudeman, Maurice A, Trines, Serge A, de Ruiter, Gijsbert S, Mertens, Bart J, Khan, Muchtair, Klautz, Robert J M, Zeppenfeld, Katja, Tjon, Andrew, Braun, Jerry, van Brakel, Thomas J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9159446/
https://www.ncbi.nlm.nih.gov/pubmed/34957518
http://dx.doi.org/10.1093/icvts/ivab355
Descripción
Sumario:OBJECTIVES: Catheter ablation of long-standing persistent atrial fibrillation (LSPAF) remains challenging, with suboptimal success rates obtained following multiple procedures. Thoracoscopic ablation has shown effective at creating transmural lesions around the pulmonary veins and box; however, long-term rhythm follow-up data are lacking. This study aims, for the first time, to assess the long-term outcomes of thoracoscopic pulmonary vein and box ablation in LSPAF. METHODS: Rhythm follow-up consisted of continuous rhythm monitoring using implanted loop recorders or 24-h Holter recordings. Rhythm status and touch-up interventions were assessed up to 5 years. RESULTS: Seventy-seven patients with symptomatic LSPAF underwent thoracoscopic ablation in 2 centres. Freedom from atrial arrhythmias at 5 years was 50% following a single thoracoscopic procedure and 68% allowing endocardial touch-up procedures (performed in 21% of patients). The mean atrial fibrillation burden in patients with continuous monitoring was reduced from 100% preoperatively to 0.1% at the end of the blanking period and 8.0% during the second year. Antiarrhythmic drug use decreased from 49.4% preoperative to 12.1% and 14.3% at 2 and 5 years, respectively (P < 0.001). Continuous rhythm monitoring resulted in higher recurrence detection rates compared to 24-h Holter monitoring at 2-year follow-up (hazard ratio: 6.5, P = 0.003), with comparable recurrence rates at 5-year follow-up. CONCLUSIONS: Thoracoscopic pulmonary vein and box isolation are effective in long-term restoration of sinus rhythm in LSPAF, especially when complemented by endocardial touch-up procedures, as demonstrated by the 68% freedom rate at 5 years. Continuous rhythm monitoring revealed earlier, but not more numerous documentation of recurrences at 5-year follow-up.