Cargando…

Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts

Accurate motor timing requires the temporally precise coupling between sensory input and motor output including the adjustment of movements with respect to changes in the environment. Such error correction has been related to a cerebello-thalamo-cortical network. At least partially distinct networks...

Descripción completa

Detalles Bibliográficos
Autores principales: Pollok, Bettina, Jurkiewicz, Martin, Krause, Vanessa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9159881/
https://www.ncbi.nlm.nih.gov/pubmed/35662740
http://dx.doi.org/10.1155/2022/9419154
_version_ 1784719154761170944
author Pollok, Bettina
Jurkiewicz, Martin
Krause, Vanessa
author_facet Pollok, Bettina
Jurkiewicz, Martin
Krause, Vanessa
author_sort Pollok, Bettina
collection PubMed
description Accurate motor timing requires the temporally precise coupling between sensory input and motor output including the adjustment of movements with respect to changes in the environment. Such error correction has been related to a cerebello-thalamo-cortical network. At least partially distinct networks for the correction of perceived (i.e., conscious) as compared to nonperceived (i.e., nonconscious) errors have been suggested. While the cerebellum, the premotor, and the prefrontal cortex seem to be involved in conscious error correction, the network subserving nonconscious error correction is less clear. The present study is aimed at investigating the functional contribution of the primary motor cortex (M1) for both types of error correction in the temporal domain. To this end, anodal transcranial direct current stimulation (atDCS) was applied to the left M1 in a group of 18 healthy young volunteers during a resting period of 10 minutes. Sensorimotor synchronization as well as error correction of the right index finger was tested immediately prior to and after atDCS. Sham stimulation served as control condition. To induce error correction, nonconscious and conscious temporal step-changes were interspersed in a sequence of an isochronous auditory pacing signal in either direction (i.e., negative or positive) yielding either shorter or longer intervals. Prior to atDCS, faster error correction in conscious as compared to nonconscious trials was observed replicating previous findings. atDCS facilitated nonconscious error correction, but only in trials with negative step-changes yielding shorter intervals. In contrast to this, neither tapping speed nor synchronization performance with respect to the isochronous pacing signal was significantly modulated by atDCS. The data suggest M1 as part of a network distinctively contributing to the correction of nonconscious negative step-changes going beyond sensorimotor synchronization.
format Online
Article
Text
id pubmed-9159881
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91598812022-06-02 Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts Pollok, Bettina Jurkiewicz, Martin Krause, Vanessa Neural Plast Research Article Accurate motor timing requires the temporally precise coupling between sensory input and motor output including the adjustment of movements with respect to changes in the environment. Such error correction has been related to a cerebello-thalamo-cortical network. At least partially distinct networks for the correction of perceived (i.e., conscious) as compared to nonperceived (i.e., nonconscious) errors have been suggested. While the cerebellum, the premotor, and the prefrontal cortex seem to be involved in conscious error correction, the network subserving nonconscious error correction is less clear. The present study is aimed at investigating the functional contribution of the primary motor cortex (M1) for both types of error correction in the temporal domain. To this end, anodal transcranial direct current stimulation (atDCS) was applied to the left M1 in a group of 18 healthy young volunteers during a resting period of 10 minutes. Sensorimotor synchronization as well as error correction of the right index finger was tested immediately prior to and after atDCS. Sham stimulation served as control condition. To induce error correction, nonconscious and conscious temporal step-changes were interspersed in a sequence of an isochronous auditory pacing signal in either direction (i.e., negative or positive) yielding either shorter or longer intervals. Prior to atDCS, faster error correction in conscious as compared to nonconscious trials was observed replicating previous findings. atDCS facilitated nonconscious error correction, but only in trials with negative step-changes yielding shorter intervals. In contrast to this, neither tapping speed nor synchronization performance with respect to the isochronous pacing signal was significantly modulated by atDCS. The data suggest M1 as part of a network distinctively contributing to the correction of nonconscious negative step-changes going beyond sensorimotor synchronization. Hindawi 2022-05-25 /pmc/articles/PMC9159881/ /pubmed/35662740 http://dx.doi.org/10.1155/2022/9419154 Text en Copyright © 2022 Bettina Pollok et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Pollok, Bettina
Jurkiewicz, Martin
Krause, Vanessa
Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title_full Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title_fullStr Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title_full_unstemmed Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title_short Anodal Transcranial Direct Current Stimulation (atDCS) of the Primary Motor Cortex (M1) Facilitates Nonconscious Error Correction of Negative Phase Shifts
title_sort anodal transcranial direct current stimulation (atdcs) of the primary motor cortex (m1) facilitates nonconscious error correction of negative phase shifts
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9159881/
https://www.ncbi.nlm.nih.gov/pubmed/35662740
http://dx.doi.org/10.1155/2022/9419154
work_keys_str_mv AT pollokbettina anodaltranscranialdirectcurrentstimulationatdcsoftheprimarymotorcortexm1facilitatesnonconsciouserrorcorrectionofnegativephaseshifts
AT jurkiewiczmartin anodaltranscranialdirectcurrentstimulationatdcsoftheprimarymotorcortexm1facilitatesnonconsciouserrorcorrectionofnegativephaseshifts
AT krausevanessa anodaltranscranialdirectcurrentstimulationatdcsoftheprimarymotorcortexm1facilitatesnonconsciouserrorcorrectionofnegativephaseshifts