Cargando…
Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160499/ https://www.ncbi.nlm.nih.gov/pubmed/35639406 http://dx.doi.org/10.1167/tvst.11.5.29 |
_version_ | 1784719282735677440 |
---|---|
author | Essig, Peter Sauer, Yannick Wahl, Siegfried |
author_facet | Essig, Peter Sauer, Yannick Wahl, Siegfried |
author_sort | Essig, Peter |
collection | PubMed |
description | PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. METHODS: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. RESULTS: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. CONCLUSIONS: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. TRANSLATIONAL RELEVANCE: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases. |
format | Online Article Text |
id | pubmed-9160499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-91604992022-06-03 Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field Essig, Peter Sauer, Yannick Wahl, Siegfried Transl Vis Sci Technol Article PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. METHODS: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. RESULTS: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. CONCLUSIONS: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. TRANSLATIONAL RELEVANCE: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases. The Association for Research in Vision and Ophthalmology 2022-05-31 /pmc/articles/PMC9160499/ /pubmed/35639406 http://dx.doi.org/10.1167/tvst.11.5.29 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License. |
spellingShingle | Article Essig, Peter Sauer, Yannick Wahl, Siegfried Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title | Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title_full | Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title_fullStr | Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title_full_unstemmed | Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title_short | Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field |
title_sort | reflexive saccades used for objective and automated measurements of contrast sensitivity in selected areas of visual field |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160499/ https://www.ncbi.nlm.nih.gov/pubmed/35639406 http://dx.doi.org/10.1167/tvst.11.5.29 |
work_keys_str_mv | AT essigpeter reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield AT saueryannick reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield AT wahlsiegfried reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield |