Cargando…

Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field

PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with...

Descripción completa

Detalles Bibliográficos
Autores principales: Essig, Peter, Sauer, Yannick, Wahl, Siegfried
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160499/
https://www.ncbi.nlm.nih.gov/pubmed/35639406
http://dx.doi.org/10.1167/tvst.11.5.29
_version_ 1784719282735677440
author Essig, Peter
Sauer, Yannick
Wahl, Siegfried
author_facet Essig, Peter
Sauer, Yannick
Wahl, Siegfried
author_sort Essig, Peter
collection PubMed
description PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. METHODS: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. RESULTS: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. CONCLUSIONS: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. TRANSLATIONAL RELEVANCE: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases.
format Online
Article
Text
id pubmed-9160499
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-91604992022-06-03 Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field Essig, Peter Sauer, Yannick Wahl, Siegfried Transl Vis Sci Technol Article PURPOSE: This study proposes a novel approach for objective and automated peripheral contrast sensitivity (CS) testing using reflexive saccades. Here the CS was examined in various areas the of visual field (VF) using a live analysis of gaze data. For validation of the new test, we examined CS with an established procedure of identifying the orientation of a contrast stimulus. METHODS: To perform and validate the saccade-based testing, two separate measurement events were performed. In the first, participants were asked to execute a saccade toward a newly-appeared stimulus in their VF. After the saccade execution or stimulus expiry, reporting the target orientation was required in a four-alternatives forced choice (4AFC). Therefore the first measurement yields two outcomes (objective and subjective). In the second measurement, only the identification of the stimulus orientation was requested, while fixating a central mark. Stimulus contrast was controlled by an adaptive psychometric procedure in both measurements. RESULTS: The study found strong correlations (all r ≥ 0.79) of CS values for all three possible testing methods (saccade-based responding in saccadic measurements, keyboard-based responding in saccadic measurements, keyboard-based responding in non-saccadic measurements), showing the feasibility of employment of reflexive saccades in such testing. Second, this study shows a significant influence of eccentricity and direction of the stimulus on the CS function. CONCLUSIONS: CS measured with reflexive saccades is comparable to other testing methods over several areas of the participant's VF. Hence, we propose it as a novel and objective testing procedure for CS measurements. TRANSLATIONAL RELEVANCE: Assessment of CS using reflexive saccades extends the portfolio of suggested eye movement-based tests, allowing objective examination across the VF, which might be helpful especially in the early detection of various eye diseases. The Association for Research in Vision and Ophthalmology 2022-05-31 /pmc/articles/PMC9160499/ /pubmed/35639406 http://dx.doi.org/10.1167/tvst.11.5.29 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Article
Essig, Peter
Sauer, Yannick
Wahl, Siegfried
Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title_full Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title_fullStr Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title_full_unstemmed Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title_short Reflexive Saccades Used for Objective and Automated Measurements of Contrast Sensitivity in Selected Areas of Visual Field
title_sort reflexive saccades used for objective and automated measurements of contrast sensitivity in selected areas of visual field
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9160499/
https://www.ncbi.nlm.nih.gov/pubmed/35639406
http://dx.doi.org/10.1167/tvst.11.5.29
work_keys_str_mv AT essigpeter reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield
AT saueryannick reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield
AT wahlsiegfried reflexivesaccadesusedforobjectiveandautomatedmeasurementsofcontrastsensitivityinselectedareasofvisualfield