Cargando…

Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints

BACKGROUND: Precise orthognathic surgical splints are important in surgical-orthodontic treatment. This study aimed to propose a standardized protocol for three-dimensional (3D)-printed splints and assess the precision of splints with different occlusal coverage on the dentition (occlusal coverage d...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yipeng, Wang, Peiqi, Xiang, Xiang, Xu, Hui, Tang, Yuting, Zhou, Yumeng, Bai, Ding, Xue, Chaoran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9161535/
https://www.ncbi.nlm.nih.gov/pubmed/35655203
http://dx.doi.org/10.1186/s12903-022-02247-6
_version_ 1784719505879990272
author Wang, Yipeng
Wang, Peiqi
Xiang, Xiang
Xu, Hui
Tang, Yuting
Zhou, Yumeng
Bai, Ding
Xue, Chaoran
author_facet Wang, Yipeng
Wang, Peiqi
Xiang, Xiang
Xu, Hui
Tang, Yuting
Zhou, Yumeng
Bai, Ding
Xue, Chaoran
author_sort Wang, Yipeng
collection PubMed
description BACKGROUND: Precise orthognathic surgical splints are important in surgical-orthodontic treatment. This study aimed to propose a standardized protocol for three-dimensional (3D)-printed splints and assess the precision of splints with different occlusal coverage on the dentition (occlusal coverage depth, OCD), thus optimizing the design of 3D-printed splints to minimize the seemingly unavoidable systematic errors. METHODS: Resin models in optimal occlusion from 19 patients were selected and scanned. Intermediate splints (ISs) and final splints (FSs) with 2-mm, 3-mm, 4-mm, and 5-mm OCDs were fabricated and grouped as IS-2, IS-3, IS-4, IS-5, FS-2, FS-3, FS-4, and FS-5, respectively. The dentitions were occluded with each splint and scanned as a whole to compare with the original occlusion. Translational and rotational deviations of the lower dentition and translational deviations of the landmarks were measured. RESULTS: For vertical translation, the lower dentitions translated inferiorly to the upper dentition in most of the splints, and the translation increased as OCD got larger. Vertical translations of the dentitions in 89.47% of IS-2, 68.42% of IS-3, 42.11% of IS-4, 10.53% of IS-5, 94.74% of FS-2, 63.16% of FS-3, 26.32% of FS-4, and 21.05% of FS-5 splints were below 1 mm, respectively. For pitch rotation, the lower dentitions rotated inferiorly and posteriorly in most groups, and the rotation increased as OCD got larger. Pitch rotations of the dentitions in 100% of IS-2, 89.47% of IS-3, 57.89% of IS-4, 52.63% of IS-5, 100.00% of FS-2, 78.95% of FS-3, 52.63% of FS-4, and 47.37% of FS-5 splints were below 2°, respectively. On the other hand, the transversal and sagittal translations, roll and yaw rotations of most groups were clinically acceptable (translation < 1 mm and rotation < 2°). The deviations of ISs and FSs showed no statistical significance at all levels of coverage (P > 0.05). CONCLUSIONS: A protocol was proposed to generate 3D-printed ISs and FSs with normalized basal planes and standardized OCDs. Deviations of the ISs and FSs were more evident in the vertical dimension and pitch rotation and had a tendency to increase as the OCD got larger. ISs and FSs with both 2-mm and 3-mm OCD are recommendable regarding the precision relative to clinical acceptability. However, considering the fabrication, structural stability, and clinical application, ISs and FSs with 3-mm OCD are recommended for accurate fitting. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12903-022-02247-6.
format Online
Article
Text
id pubmed-9161535
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-91615352022-06-03 Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints Wang, Yipeng Wang, Peiqi Xiang, Xiang Xu, Hui Tang, Yuting Zhou, Yumeng Bai, Ding Xue, Chaoran BMC Oral Health Research BACKGROUND: Precise orthognathic surgical splints are important in surgical-orthodontic treatment. This study aimed to propose a standardized protocol for three-dimensional (3D)-printed splints and assess the precision of splints with different occlusal coverage on the dentition (occlusal coverage depth, OCD), thus optimizing the design of 3D-printed splints to minimize the seemingly unavoidable systematic errors. METHODS: Resin models in optimal occlusion from 19 patients were selected and scanned. Intermediate splints (ISs) and final splints (FSs) with 2-mm, 3-mm, 4-mm, and 5-mm OCDs were fabricated and grouped as IS-2, IS-3, IS-4, IS-5, FS-2, FS-3, FS-4, and FS-5, respectively. The dentitions were occluded with each splint and scanned as a whole to compare with the original occlusion. Translational and rotational deviations of the lower dentition and translational deviations of the landmarks were measured. RESULTS: For vertical translation, the lower dentitions translated inferiorly to the upper dentition in most of the splints, and the translation increased as OCD got larger. Vertical translations of the dentitions in 89.47% of IS-2, 68.42% of IS-3, 42.11% of IS-4, 10.53% of IS-5, 94.74% of FS-2, 63.16% of FS-3, 26.32% of FS-4, and 21.05% of FS-5 splints were below 1 mm, respectively. For pitch rotation, the lower dentitions rotated inferiorly and posteriorly in most groups, and the rotation increased as OCD got larger. Pitch rotations of the dentitions in 100% of IS-2, 89.47% of IS-3, 57.89% of IS-4, 52.63% of IS-5, 100.00% of FS-2, 78.95% of FS-3, 52.63% of FS-4, and 47.37% of FS-5 splints were below 2°, respectively. On the other hand, the transversal and sagittal translations, roll and yaw rotations of most groups were clinically acceptable (translation < 1 mm and rotation < 2°). The deviations of ISs and FSs showed no statistical significance at all levels of coverage (P > 0.05). CONCLUSIONS: A protocol was proposed to generate 3D-printed ISs and FSs with normalized basal planes and standardized OCDs. Deviations of the ISs and FSs were more evident in the vertical dimension and pitch rotation and had a tendency to increase as the OCD got larger. ISs and FSs with both 2-mm and 3-mm OCD are recommendable regarding the precision relative to clinical acceptability. However, considering the fabrication, structural stability, and clinical application, ISs and FSs with 3-mm OCD are recommended for accurate fitting. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12903-022-02247-6. BioMed Central 2022-06-02 /pmc/articles/PMC9161535/ /pubmed/35655203 http://dx.doi.org/10.1186/s12903-022-02247-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Wang, Yipeng
Wang, Peiqi
Xiang, Xiang
Xu, Hui
Tang, Yuting
Zhou, Yumeng
Bai, Ding
Xue, Chaoran
Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title_full Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title_fullStr Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title_full_unstemmed Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title_short Effect of occlusal coverage depths on the precision of 3D-printed orthognathic surgical splints
title_sort effect of occlusal coverage depths on the precision of 3d-printed orthognathic surgical splints
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9161535/
https://www.ncbi.nlm.nih.gov/pubmed/35655203
http://dx.doi.org/10.1186/s12903-022-02247-6
work_keys_str_mv AT wangyipeng effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT wangpeiqi effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT xiangxiang effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT xuhui effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT tangyuting effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT zhouyumeng effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT baiding effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints
AT xuechaoran effectofocclusalcoveragedepthsontheprecisionof3dprintedorthognathicsurgicalsplints