Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules

Ultrafast, portable, and inexpensive molecular diagnostic platforms are critical for clinical diagnosis and on-site detection. There are currently no available real-time polymerase chain reaction (PCR) devices able to meet the demands of point-of-care testing, as the heating and cooling processes ca...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Shan, Song, Xiaojun, Zhu, Kun, Shao, Quanyu, Chen, Yinhang, Cheng, Wei, Lei, Zhijing, Chen, Yu, Luo, Yun, Jin, Dazhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9162139/
https://www.ncbi.nlm.nih.gov/pubmed/35662850
http://dx.doi.org/10.3389/fbioe.2022.895236
_version_ 1784719634216255488
author Lin, Shan
Song, Xiaojun
Zhu, Kun
Shao, Quanyu
Chen, Yinhang
Cheng, Wei
Lei, Zhijing
Chen, Yu
Luo, Yun
Jin, Dazhi
author_facet Lin, Shan
Song, Xiaojun
Zhu, Kun
Shao, Quanyu
Chen, Yinhang
Cheng, Wei
Lei, Zhijing
Chen, Yu
Luo, Yun
Jin, Dazhi
author_sort Lin, Shan
collection PubMed
description Ultrafast, portable, and inexpensive molecular diagnostic platforms are critical for clinical diagnosis and on-site detection. There are currently no available real-time polymerase chain reaction (PCR) devices able to meet the demands of point-of-care testing, as the heating and cooling processes cannot be avoided. In this study, the dual temperature modules were first designed to process microfluidic chips automatically circulating between them. Thus, a novel ultrafast molecular diagnostic real-time PCR device (approximately 18 and 23 min for DNA and RNA detection, respectively) with two channels (FAM and Cy5) for the detection of 12 targets was developed. The device contained three core functional components, including temperature control, optics, and motion, which were integrated into a portable compact box. The temperature modules accurately control temperature in rapid thermal cycles with less than ±0.1 °C, ±1 °C and ±0.5 °C for the temperature fluctuation, uniformity, and error of indication, respectively. The average coefficient of variation (CV) of the fluorescence intensity (FI) for all 12 wells was 2.3% for FAM and 2.7% for Cy5. There was a good linear relationship between the concentrations of fluorescent dye and the FIs of FAM and Cy5(R (2) = 0.9990 and 0.9937), and the average CVs of the Ct values calculated by the embedded software were 1.4% for FAM and Cy5, respectively. The 100 double-blind mocked sputum and 249 clinical stool samples were analyzed by the ultrafast real-time PCR device in comparison with the DAAN Gene SARS-CoV-2 kit run on the ABI 7500 instrument and Xpert C. difficile/Epi, respectively. Among the 249 stool samples, the ultrafast real-time PCR device detected toxigenic C. difficile in 54 samples (54/249, 21.7%) with a specificity and positive predictive values of 99.0 and 96.3%, which were higher than the Xpert C. difficile/Epi values of 94.4 and 88.1% (p > 0.05). The ultrafast real-time PCR device detected 15 SARS-CoV-2 positive samples, which has a 100% concordance with that obtained by the DAAN Gene SARS-CoV-2 kit. This study demonstrated that the ultrafast real-time PCR device integrated with microfluidic chips and dual temperature modules is an ultrafast, reliable, easy-to-use, and cost-effective molecular diagnostic platform for clinical diagnosis and on-site testing, especially in resource-limited settings.
format Online
Article
Text
id pubmed-9162139
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-91621392022-06-03 Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules Lin, Shan Song, Xiaojun Zhu, Kun Shao, Quanyu Chen, Yinhang Cheng, Wei Lei, Zhijing Chen, Yu Luo, Yun Jin, Dazhi Front Bioeng Biotechnol Bioengineering and Biotechnology Ultrafast, portable, and inexpensive molecular diagnostic platforms are critical for clinical diagnosis and on-site detection. There are currently no available real-time polymerase chain reaction (PCR) devices able to meet the demands of point-of-care testing, as the heating and cooling processes cannot be avoided. In this study, the dual temperature modules were first designed to process microfluidic chips automatically circulating between them. Thus, a novel ultrafast molecular diagnostic real-time PCR device (approximately 18 and 23 min for DNA and RNA detection, respectively) with two channels (FAM and Cy5) for the detection of 12 targets was developed. The device contained three core functional components, including temperature control, optics, and motion, which were integrated into a portable compact box. The temperature modules accurately control temperature in rapid thermal cycles with less than ±0.1 °C, ±1 °C and ±0.5 °C for the temperature fluctuation, uniformity, and error of indication, respectively. The average coefficient of variation (CV) of the fluorescence intensity (FI) for all 12 wells was 2.3% for FAM and 2.7% for Cy5. There was a good linear relationship between the concentrations of fluorescent dye and the FIs of FAM and Cy5(R (2) = 0.9990 and 0.9937), and the average CVs of the Ct values calculated by the embedded software were 1.4% for FAM and Cy5, respectively. The 100 double-blind mocked sputum and 249 clinical stool samples were analyzed by the ultrafast real-time PCR device in comparison with the DAAN Gene SARS-CoV-2 kit run on the ABI 7500 instrument and Xpert C. difficile/Epi, respectively. Among the 249 stool samples, the ultrafast real-time PCR device detected toxigenic C. difficile in 54 samples (54/249, 21.7%) with a specificity and positive predictive values of 99.0 and 96.3%, which were higher than the Xpert C. difficile/Epi values of 94.4 and 88.1% (p > 0.05). The ultrafast real-time PCR device detected 15 SARS-CoV-2 positive samples, which has a 100% concordance with that obtained by the DAAN Gene SARS-CoV-2 kit. This study demonstrated that the ultrafast real-time PCR device integrated with microfluidic chips and dual temperature modules is an ultrafast, reliable, easy-to-use, and cost-effective molecular diagnostic platform for clinical diagnosis and on-site testing, especially in resource-limited settings. Frontiers Media S.A. 2022-05-19 /pmc/articles/PMC9162139/ /pubmed/35662850 http://dx.doi.org/10.3389/fbioe.2022.895236 Text en Copyright © 2022 Lin, Song, Zhu, Shao, Chen, Cheng, Lei, Chen, Luo and Jin. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Lin, Shan
Song, Xiaojun
Zhu, Kun
Shao, Quanyu
Chen, Yinhang
Cheng, Wei
Lei, Zhijing
Chen, Yu
Luo, Yun
Jin, Dazhi
Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title_full Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title_fullStr Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title_full_unstemmed Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title_short Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules
title_sort performance evaluation of a novel ultrafast molecular diagnostic device integrated with microfluidic chips and dual temperature modules
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9162139/
https://www.ncbi.nlm.nih.gov/pubmed/35662850
http://dx.doi.org/10.3389/fbioe.2022.895236
work_keys_str_mv AT linshan performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT songxiaojun performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT zhukun performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT shaoquanyu performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT chenyinhang performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT chengwei performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT leizhijing performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT chenyu performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT luoyun performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules
AT jindazhi performanceevaluationofanovelultrafastmoleculardiagnosticdeviceintegratedwithmicrofluidicchipsanddualtemperaturemodules