Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test
INTRODUCTION: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Som...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cirurgia Cardiovascular
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9162417/ https://www.ncbi.nlm.nih.gov/pubmed/35605215 http://dx.doi.org/10.21470/1678-9741-2021-0272 |
_version_ | 1784719700076265472 |
---|---|
author | Mota, Andre Lupp Gaia, Diego Felipe da Fonseca, José Honório Palma |
author_facet | Mota, Andre Lupp Gaia, Diego Felipe da Fonseca, José Honório Palma |
author_sort | Mota, Andre Lupp |
collection | PubMed |
description | INTRODUCTION: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. METHODS: One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. RESULTS: All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. CONCLUSION: All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses. |
format | Online Article Text |
id | pubmed-9162417 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
record_format | MEDLINE/PubMed |
spelling | pubmed-91624172022-06-13 Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test Mota, Andre Lupp Gaia, Diego Felipe da Fonseca, José Honório Palma Braz J Cardiovasc Surg Original Article INTRODUCTION: Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. METHODS: One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. RESULTS: All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. CONCLUSION: All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses. Sociedade Brasileira de Cirurgia Cardiovascular 2022 /pmc/articles/PMC9162417/ /pubmed/35605215 http://dx.doi.org/10.21470/1678-9741-2021-0272 Text en https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mota, Andre Lupp Gaia, Diego Felipe da Fonseca, José Honório Palma Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title | Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title_full | Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title_fullStr | Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title_full_unstemmed | Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title_short | Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test |
title_sort | ring fracture of brazilian aortic valve bioprostheses using non-compliant high-pressure transcatheter balloon, an ex vivo test |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9162417/ https://www.ncbi.nlm.nih.gov/pubmed/35605215 http://dx.doi.org/10.21470/1678-9741-2021-0272 |
work_keys_str_mv | AT motaandrelupp ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest AT gaiadiegofelipe ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest AT dafonsecajosehonoriopalma ringfractureofbrazilianaorticvalvebioprosthesesusingnoncomplianthighpressuretranscatheterballoonanexvivotest |