Cargando…

Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms

Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedur...

Descripción completa

Detalles Bibliográficos
Autores principales: Vivanco-Suarez, Juan, Feigen, Chaim, Javed, Kainaat, Dardick, Joseph M., Holland, Ryan, Mendez-Ruiz, Alan, Ortega-Gutierrez, Santiago, Haranhalli, Neil, Altschul, David J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9163419/
https://www.ncbi.nlm.nih.gov/pubmed/35669008
http://dx.doi.org/10.1016/j.dib.2022.108299
_version_ 1784719916924928000
author Vivanco-Suarez, Juan
Feigen, Chaim
Javed, Kainaat
Dardick, Joseph M.
Holland, Ryan
Mendez-Ruiz, Alan
Ortega-Gutierrez, Santiago
Haranhalli, Neil
Altschul, David J.
author_facet Vivanco-Suarez, Juan
Feigen, Chaim
Javed, Kainaat
Dardick, Joseph M.
Holland, Ryan
Mendez-Ruiz, Alan
Ortega-Gutierrez, Santiago
Haranhalli, Neil
Altschul, David J.
author_sort Vivanco-Suarez, Juan
collection PubMed
description Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, or Surpass Streamline on 126 subjects with intracranial aneurysms [1]. The retrospective data were collected from electronic medical records at two large tertiary centers. Baseline patient data included age, sex, and medical comorbidities. The dataset also describes aneurysm characteristics including laterality, anatomic location, morphology, dome height, and neck width. In addition, digital subtraction images showing the internal carotid artery tortuosity were included for aneurysms in the anterior cerebral circulation [2]. Procedural data include case duration, radiation exposure, number of flow diverters deployed, and complications encountered during deployment. In addition, data related to the duration of hospitalization and postoperative adverse events are included. Finally, time to follow up and rates of total aneurysm obliteration at first and second postoperative visits are included. This data is propensity score matching are included. This data is presented as a starting point for future prospective comparisons in the safety and efficacy of flow diverters as more devices become approved and commercially available.
format Online
Article
Text
id pubmed-9163419
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-91634192022-06-05 Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms Vivanco-Suarez, Juan Feigen, Chaim Javed, Kainaat Dardick, Joseph M. Holland, Ryan Mendez-Ruiz, Alan Ortega-Gutierrez, Santiago Haranhalli, Neil Altschul, David J. Data Brief Data Article Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, or Surpass Streamline on 126 subjects with intracranial aneurysms [1]. The retrospective data were collected from electronic medical records at two large tertiary centers. Baseline patient data included age, sex, and medical comorbidities. The dataset also describes aneurysm characteristics including laterality, anatomic location, morphology, dome height, and neck width. In addition, digital subtraction images showing the internal carotid artery tortuosity were included for aneurysms in the anterior cerebral circulation [2]. Procedural data include case duration, radiation exposure, number of flow diverters deployed, and complications encountered during deployment. In addition, data related to the duration of hospitalization and postoperative adverse events are included. Finally, time to follow up and rates of total aneurysm obliteration at first and second postoperative visits are included. This data is propensity score matching are included. This data is presented as a starting point for future prospective comparisons in the safety and efficacy of flow diverters as more devices become approved and commercially available. Elsevier 2022-05-21 /pmc/articles/PMC9163419/ /pubmed/35669008 http://dx.doi.org/10.1016/j.dib.2022.108299 Text en © 2022 The Author(s). Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Vivanco-Suarez, Juan
Feigen, Chaim
Javed, Kainaat
Dardick, Joseph M.
Holland, Ryan
Mendez-Ruiz, Alan
Ortega-Gutierrez, Santiago
Haranhalli, Neil
Altschul, David J.
Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title_full Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title_fullStr Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title_full_unstemmed Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title_short Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms
title_sort dataset on flow diversion procedures performed with the pipeline embolization device, pipeline flex, and surpass streamline for intracranial aneurysms
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9163419/
https://www.ncbi.nlm.nih.gov/pubmed/35669008
http://dx.doi.org/10.1016/j.dib.2022.108299
work_keys_str_mv AT vivancosuarezjuan datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT feigenchaim datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT javedkainaat datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT dardickjosephm datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT hollandryan datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT mendezruizalan datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT ortegagutierrezsantiago datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT haranhallineil datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms
AT altschuldavidj datasetonflowdiversionproceduresperformedwiththepipelineembolizationdevicepipelineflexandsurpassstreamlineforintracranialaneurysms