Cargando…
IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T
INTRODUCTION: In hospitals with heavily utilised MRI scanners, it may not be possible to schedule the patient on 1 particular scanner for all scans and thus this project was carried out to determine if there is any significant difference in the spectroscopy profile between 1.5 T and 3T MRI scanners...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9164728/ http://dx.doi.org/10.1093/neuonc/noac079.282 |
_version_ | 1784720204828246016 |
---|---|
author | Tang, Phua Hwee Nisa, Sameema |
author_facet | Tang, Phua Hwee Nisa, Sameema |
author_sort | Tang, Phua Hwee |
collection | PubMed |
description | INTRODUCTION: In hospitals with heavily utilised MRI scanners, it may not be possible to schedule the patient on 1 particular scanner for all scans and thus this project was carried out to determine if there is any significant difference in the spectroscopy profile between 1.5 T and 3T MRI scanners late year 2021. AIM: To describe the MR spectroscopy profile of normal brain tissue performed on 1.5T and 3T MRI scanners in KK Women’s and Children’s Hospital. METHODS: Three healthy adult volunteers with normal body mass index underwent MRI brain scans after informed consent in this Institute Review Board approved study. MRI brain scans were performed on 1.5T General Electric MRI scanner and 3T Siemens Skyra MRI scanner 1 week apart. NAA/Cr, Cho/Cr and Cho/ NAA values were obtained from the right and left cerebral hemispheres. RESULTS: Average NAA/Cr in the right cerebral hemisphere is 2.06+/-0.10 at 1.5T. Average NAA/Cr in the left cerebral hemisphere is 2.01+/-0.23 at 1.5T. Average NAA/Cr in the right cerebral hemisphere is 1.56+/-0.09 at 3T. Average NAA/Cr in the left cerebral hemisphere is 1.81+/-0.29 at 3T. Average Cho/Cr in the right cerebral hemisphere 1.06+/-0.14 at 1.5T. Average Cho/Cr in the left cerebral hemisphere is 1.11+/-0.22 at 1.5T. Average Cho/Cr in the right cerebral hemisphere is 0.90+/-0.05 at 3T. Average Cho/Cr in the left cerebral hemisphere is 0.95+/-0.27 at 3T. Average Cho/NAA in the right cerebral hemisphere is 0.51+/-0.06 at 1.5T. Average Cho/NAA in the left cerebral hemisphere is 0.58+/-0.00 at 1.5T. Average Cho/NAA in the right cerebral hemisphere is 0.55+/-0.05 at 3T. Average Cho/NAA in the left cerebral hemisphere is 0.52+/-0.07 at 3T. CONCLUSION: MR spectroscopy values obtained from 1.5T and 3T MRI scanners show no significant difference(P>0.05). |
format | Online Article Text |
id | pubmed-9164728 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-91647282022-06-05 IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T Tang, Phua Hwee Nisa, Sameema Neuro Oncol Imaging INTRODUCTION: In hospitals with heavily utilised MRI scanners, it may not be possible to schedule the patient on 1 particular scanner for all scans and thus this project was carried out to determine if there is any significant difference in the spectroscopy profile between 1.5 T and 3T MRI scanners late year 2021. AIM: To describe the MR spectroscopy profile of normal brain tissue performed on 1.5T and 3T MRI scanners in KK Women’s and Children’s Hospital. METHODS: Three healthy adult volunteers with normal body mass index underwent MRI brain scans after informed consent in this Institute Review Board approved study. MRI brain scans were performed on 1.5T General Electric MRI scanner and 3T Siemens Skyra MRI scanner 1 week apart. NAA/Cr, Cho/Cr and Cho/ NAA values were obtained from the right and left cerebral hemispheres. RESULTS: Average NAA/Cr in the right cerebral hemisphere is 2.06+/-0.10 at 1.5T. Average NAA/Cr in the left cerebral hemisphere is 2.01+/-0.23 at 1.5T. Average NAA/Cr in the right cerebral hemisphere is 1.56+/-0.09 at 3T. Average NAA/Cr in the left cerebral hemisphere is 1.81+/-0.29 at 3T. Average Cho/Cr in the right cerebral hemisphere 1.06+/-0.14 at 1.5T. Average Cho/Cr in the left cerebral hemisphere is 1.11+/-0.22 at 1.5T. Average Cho/Cr in the right cerebral hemisphere is 0.90+/-0.05 at 3T. Average Cho/Cr in the left cerebral hemisphere is 0.95+/-0.27 at 3T. Average Cho/NAA in the right cerebral hemisphere is 0.51+/-0.06 at 1.5T. Average Cho/NAA in the left cerebral hemisphere is 0.58+/-0.00 at 1.5T. Average Cho/NAA in the right cerebral hemisphere is 0.55+/-0.05 at 3T. Average Cho/NAA in the left cerebral hemisphere is 0.52+/-0.07 at 3T. CONCLUSION: MR spectroscopy values obtained from 1.5T and 3T MRI scanners show no significant difference(P>0.05). Oxford University Press 2022-06-03 /pmc/articles/PMC9164728/ http://dx.doi.org/10.1093/neuonc/noac079.282 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the Society for Neuro-Oncology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Imaging Tang, Phua Hwee Nisa, Sameema IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title | IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title_full | IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title_fullStr | IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title_full_unstemmed | IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title_short | IMG-06. Comparing between MR spectroscopy done at 1.5T and 3T |
title_sort | img-06. comparing between mr spectroscopy done at 1.5t and 3t |
topic | Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9164728/ http://dx.doi.org/10.1093/neuonc/noac079.282 |
work_keys_str_mv | AT tangphuahwee img06comparingbetweenmrspectroscopydoneat15tand3t AT nisasameema img06comparingbetweenmrspectroscopydoneat15tand3t |