Cargando…

Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies

This study tests the geometrical parameterization method for Electrical Bio-Impedance Spectroscopy (EBIS) readings previously proposed by one of the authors. This method uses the data of just three frequencies (therefore called 3P method). The test was carried out by the analysis of parameterization...

Descripción completa

Detalles Bibliográficos
Autores principales: González-Correa, C. A., Jaimes, S. A., Cárdenas-Jiménez, J. I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9166711/
https://www.ncbi.nlm.nih.gov/pubmed/35661777
http://dx.doi.org/10.1038/s41598-022-13299-7
_version_ 1784720665752895488
author González-Correa, C. A.
Jaimes, S. A.
Cárdenas-Jiménez, J. I.
author_facet González-Correa, C. A.
Jaimes, S. A.
Cárdenas-Jiménez, J. I.
author_sort González-Correa, C. A.
collection PubMed
description This study tests the geometrical parameterization method for Electrical Bio-Impedance Spectroscopy (EBIS) readings previously proposed by one of the authors. This method uses the data of just three frequencies (therefore called 3P method). The test was carried out by the analysis of parameterization from 26 spectra (selected from 13 data sets) by the non-linear square (NLS) method, the 3P method and a combination of the two (3P-NLS). Additionally, the behaviour of the 3P method for 4 levels of noise and 3 different ways of segmenting the spectra were also explored with a MATLAB simulation of 400 spectra. Finally, a system for the classification of EBIS readings is presented, based on deviations of the raw data from the semi-circle obtained by the parameterization methods. Overall, the results suggest a very good performance of the 3P method when compared with the other two. The 3P method performs very well with levels of noise of 1 and 2%, but performs poorly with levels of noise of 5% and 10%. The results support the idea that the 3P method could be used with confidence for the parameterization of EBIS spectra, after the selection of three adequate frequencies according to specific applications.
format Online
Article
Text
id pubmed-9166711
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-91667112022-06-05 Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies González-Correa, C. A. Jaimes, S. A. Cárdenas-Jiménez, J. I. Sci Rep Article This study tests the geometrical parameterization method for Electrical Bio-Impedance Spectroscopy (EBIS) readings previously proposed by one of the authors. This method uses the data of just three frequencies (therefore called 3P method). The test was carried out by the analysis of parameterization from 26 spectra (selected from 13 data sets) by the non-linear square (NLS) method, the 3P method and a combination of the two (3P-NLS). Additionally, the behaviour of the 3P method for 4 levels of noise and 3 different ways of segmenting the spectra were also explored with a MATLAB simulation of 400 spectra. Finally, a system for the classification of EBIS readings is presented, based on deviations of the raw data from the semi-circle obtained by the parameterization methods. Overall, the results suggest a very good performance of the 3P method when compared with the other two. The 3P method performs very well with levels of noise of 1 and 2%, but performs poorly with levels of noise of 5% and 10%. The results support the idea that the 3P method could be used with confidence for the parameterization of EBIS spectra, after the selection of three adequate frequencies according to specific applications. Nature Publishing Group UK 2022-06-03 /pmc/articles/PMC9166711/ /pubmed/35661777 http://dx.doi.org/10.1038/s41598-022-13299-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
González-Correa, C. A.
Jaimes, S. A.
Cárdenas-Jiménez, J. I.
Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title_full Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title_fullStr Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title_full_unstemmed Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title_short Preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
title_sort preliminary study on parameterization of raw electrical bioimpedance data with 3 frequencies
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9166711/
https://www.ncbi.nlm.nih.gov/pubmed/35661777
http://dx.doi.org/10.1038/s41598-022-13299-7
work_keys_str_mv AT gonzalezcorreaca preliminarystudyonparameterizationofrawelectricalbioimpedancedatawith3frequencies
AT jaimessa preliminarystudyonparameterizationofrawelectricalbioimpedancedatawith3frequencies
AT cardenasjimenezji preliminarystudyonparameterizationofrawelectricalbioimpedancedatawith3frequencies