Cargando…
Electromagnetically-driven integrated microfluidic platform using reverse transcription loop-mediated isothermal amplification for detection of severe acute respiratory syndrome coronavirus 2
Rapid, sensitive and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is of great need for effective quarantining and treatment. Real-time reverse-transcription polymerase chain reaction requiring thermocyling has been commonly used for diagnosis of SARS-CoV-2 thoug...
Autores principales: | Tsai, Yu-Shiuan, Wang, Chih-Hung, Tsai, Huey-Pin, Shan, Yan-Shen, Lee, Gwo-Bin |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9167649/ https://www.ncbi.nlm.nih.gov/pubmed/35715135 http://dx.doi.org/10.1016/j.aca.2022.340036 |
Ejemplares similares
-
An integrated microfluidic platform featuring real-time reverse transcription loop-mediated isothermal amplification for detection of COVID-19
por: Jhou, You-Ru, et al.
Publicado: (2022) -
A Digital Microfluidics Platform for Loop-Mediated Isothermal Amplification Detection
por: Coelho, Beatriz Jorge, et al.
Publicado: (2017) -
Loop-Mediated Isothermal Amplification–Based Microfluidic Platforms for the Detection of Viral Infections
por: Zeng, Yuanyuan, et al.
Publicado: (2022) -
Reverse transcriptase loop-mediated isothermal amplification for the detection of feline coronavirus
por: Stranieri, Angelica, et al.
Publicado: (2017) -
Reverse transcription-loop-mediated isothermal amplification for the detection of rodent coronaviruses
por: Hanaki, Ken-Ichi, et al.
Publicado: (2013)