Cargando…

Respiratory distress observation scales to predict weaning outcome

BACKGROUND: Whether dyspnea is present before starting a spontaneous breathing trial (SBT) and whether it may affect the outcome of the SBT is unknown. Mechanical Ventilation—Respiratory Distress Observation Scale (MV-RDOS) has been proposed as a reliable surrogate of dyspnea in non-communicative in...

Descripción completa

Detalles Bibliográficos
Autores principales: Decavèle, Maxens, Rozenberg, Emmanuel, Niérat, Marie-Cécile, Mayaux, Julien, Morawiec, Elise, Morélot-Panzini, Capucine, Similowski, Thomas, Demoule, Alexandre, Dres, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9169318/
https://www.ncbi.nlm.nih.gov/pubmed/35668459
http://dx.doi.org/10.1186/s13054-022-04028-7
Descripción
Sumario:BACKGROUND: Whether dyspnea is present before starting a spontaneous breathing trial (SBT) and whether it may affect the outcome of the SBT is unknown. Mechanical Ventilation—Respiratory Distress Observation Scale (MV-RDOS) has been proposed as a reliable surrogate of dyspnea in non-communicative intubated patients. In the present study, we sought (1) to describe the evolution of the MV-RDOS during a SBT and (2) to investigate whether MV-RDOS can predict the outcome of the SBT. METHODS: Prospective, single-center study in a twenty-two bed ICU in a tertiary center. Patients intubated since more 48 h who had failed a first SBT were eligible if they meet classical readiness to wean criteria. The MV-RDOS was assessed before, at 2-min, 15-min and 30-min (end) of the SBT. The presence of clinically important dyspnea was inferred by a MV-RDOS value ≥  2.6. RESULTS: Fifty-eight patients (age 63 [51–70], SAPS II 66 [51–76]; med [IQR]) were included. Thirty-three (57%) patients failed the SBT, whose 18 (55%) failed before 15-min. Twenty-five (43%) patients successfully passed the SBT. A MV-RDOS ≥ 2.6 was present in ten (17%) patients before to start the SBT. All these ten patients subsequently failed the SBT. A MV-RDOS ≥ 2.6 at 2-min predicted a SBT failure with a 51% sensibility and a 88% specificity (AUC 0.741 95% confidence interval [CI] 0.616–0.866, p = 0.002). Best cut-off value at 2-min was 4.3 and predicted SBT failure with a 27% sensibility and a 96% specificity. CONCLUSION: Despite patients met classical readiness to wean criteria, respiratory distress assessed with the MV-RDOS was frequent at the beginning of SBT. Measuring MV-RDOS before to initiate a SBT could avoid undue procedure and reduce patient’s exposure to unnecessary mechanical ventilation weaning failure and distress. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13054-022-04028-7.