Cargando…
Assessment of the diagnostic performance of two new tools versus routine screening instruments for bipolar disorder: a meta-analysis
OBJECTIVE: The present meta-analysis was conducted to determine the diagnostic accuracy of the bipolarity index (BI) and Rapid Mode Screener (RMS) as compared with the Bipolar Spectrum Diagnostic Scale (BSDS), the Hypomania Checklist (HCL-32), and the Mood Disorder Questionnaire (MDQ) in people with...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Associação Brasileira de Psiquiatria
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9169473/ https://www.ncbi.nlm.nih.gov/pubmed/35588536 http://dx.doi.org/10.1590/1516-4446-2021-2334 |
Sumario: | OBJECTIVE: The present meta-analysis was conducted to determine the diagnostic accuracy of the bipolarity index (BI) and Rapid Mode Screener (RMS) as compared with the Bipolar Spectrum Diagnostic Scale (BSDS), the Hypomania Checklist (HCL-32), and the Mood Disorder Questionnaire (MDQ) in people with bipolar disorder (BD). METHODS: We systematically searched five databases using standard search terms, and relevant articles published between May 1990 and November 30, 2021 were collected and reviewed. RESULTS: Ninety-three original studies were included (n=62,291). At the recommended cutoffs for the BI, HCL-32, BSDS, MDQ, and RMS, the pooled sensitivities were 0.82, 0.75, 0.71, 0.71, and 0.78, respectively, while the corresponding pooled specificities were 0.73, 0.63, 0.73, 0.77, and 0.72, respectively. However, there was evidence that the accuracy of the BI was superior to that of the other tests, with a relative diagnostic odds ratio (RDOR) of 1.22 (0.98-1.52, p < 0.0001). The RMS was significantly more accurate than the other tests, with an RDOR (95%CI) of 0.79 (0.67-0.92, p < 0.0001) for the detection of BD type I (BD-I). However, there was evidence that the accuracy of the MDQ was superior to that of the other tests, with an RDOR of 1.93 (0.89-2.79, p = 0.0019), for the detection of BD type II (BD-II). CONCLUSION: The psychometric properties of two new instruments, the BI and RMS, in people with BD were consistent with considerably higher diagnostic accuracy than the HCL-32, BSDS, and MDQ. However, a positive screening should be confirmed by a clinical diagnostic evaluation for BD. |
---|