Cargando…
Clinical reliability and usability of smartphone goniometers for hip range of motion measurement
[Purpose] This study aimed to utilize the objective measurements and a survey questionnaire for assessing the intra- and inter-rater reliability, measurement time, and usability of a smartphone application type of goniometer to measure the hip joint angles. [Participants and Methods] Three examiners...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9170486/ https://www.ncbi.nlm.nih.gov/pubmed/35698549 http://dx.doi.org/10.1589/jpts.34.433 |
_version_ | 1784721437218570240 |
---|---|
author | Takeda, Yugo Furukawa, Katsuhiro |
author_facet | Takeda, Yugo Furukawa, Katsuhiro |
author_sort | Takeda, Yugo |
collection | PubMed |
description | [Purpose] This study aimed to utilize the objective measurements and a survey questionnaire for assessing the intra- and inter-rater reliability, measurement time, and usability of a smartphone application type of goniometer to measure the hip joint angles. [Participants and Methods] Three examiners (physiotherapists) measured the hip joint range of motion using universal and smartphone goniometers on 30 daycare center rehabilitation patients. Reliability was calculated using the intra-class correlation coefficient. The examiners completed a questionnaire survey for assessing the usability of the goniometers. [Results] The intra-rater reliability was high, but the inter-rater reliability was low. Measurement times using the two instruments showed no difference. The usability questionnaire findings suggested that the smartphone goniometer was easier to use than the universal goniometer. [Conclusion] Reliability within the raters was high, but reliability among the raters was low. However, both goniometric devices provided a satisfactory range of motion measurement data when a single evaluator used the same device for all measurements. |
format | Online Article Text |
id | pubmed-9170486 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-91704862022-06-12 Clinical reliability and usability of smartphone goniometers for hip range of motion measurement Takeda, Yugo Furukawa, Katsuhiro J Phys Ther Sci Original Article [Purpose] This study aimed to utilize the objective measurements and a survey questionnaire for assessing the intra- and inter-rater reliability, measurement time, and usability of a smartphone application type of goniometer to measure the hip joint angles. [Participants and Methods] Three examiners (physiotherapists) measured the hip joint range of motion using universal and smartphone goniometers on 30 daycare center rehabilitation patients. Reliability was calculated using the intra-class correlation coefficient. The examiners completed a questionnaire survey for assessing the usability of the goniometers. [Results] The intra-rater reliability was high, but the inter-rater reliability was low. Measurement times using the two instruments showed no difference. The usability questionnaire findings suggested that the smartphone goniometer was easier to use than the universal goniometer. [Conclusion] Reliability within the raters was high, but reliability among the raters was low. However, both goniometric devices provided a satisfactory range of motion measurement data when a single evaluator used the same device for all measurements. The Society of Physical Therapy Science 2022-06-06 2022-06 /pmc/articles/PMC9170486/ /pubmed/35698549 http://dx.doi.org/10.1589/jpts.34.433 Text en 2022©by the Society of Physical Therapy Science. Published by IPEC Inc. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. (CC-BY-NC-ND 4.0: https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Original Article Takeda, Yugo Furukawa, Katsuhiro Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title | Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title_full | Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title_fullStr | Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title_full_unstemmed | Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title_short | Clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
title_sort | clinical reliability and usability of smartphone goniometers for hip range of motion measurement |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9170486/ https://www.ncbi.nlm.nih.gov/pubmed/35698549 http://dx.doi.org/10.1589/jpts.34.433 |
work_keys_str_mv | AT takedayugo clinicalreliabilityandusabilityofsmartphonegoniometersforhiprangeofmotionmeasurement AT furukawakatsuhiro clinicalreliabilityandusabilityofsmartphonegoniometersforhiprangeofmotionmeasurement |