Cargando…

An all-in-one point-of-care testing device for multiplexed detection of respiratory infections

The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approac...

Descripción completa

Detalles Bibliográficos
Autores principales: Teixeira, William, Pallás-Tamarit, Yeray, Juste-Dolz, Augusto, Sena-Torralba, Amadeo, Gozalbo-Rovira, Roberto, Rodríguez-Díaz, Jesús, Navarro, David, Carrascosa, Javier, Gimenez-Romero, David, Maquieira, Ángel, Morais, Sergi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176175/
https://www.ncbi.nlm.nih.gov/pubmed/35696866
http://dx.doi.org/10.1016/j.bios.2022.114454
_version_ 1784722608033366016
author Teixeira, William
Pallás-Tamarit, Yeray
Juste-Dolz, Augusto
Sena-Torralba, Amadeo
Gozalbo-Rovira, Roberto
Rodríguez-Díaz, Jesús
Navarro, David
Carrascosa, Javier
Gimenez-Romero, David
Maquieira, Ángel
Morais, Sergi
author_facet Teixeira, William
Pallás-Tamarit, Yeray
Juste-Dolz, Augusto
Sena-Torralba, Amadeo
Gozalbo-Rovira, Roberto
Rodríguez-Díaz, Jesús
Navarro, David
Carrascosa, Javier
Gimenez-Romero, David
Maquieira, Ángel
Morais, Sergi
author_sort Teixeira, William
collection PubMed
description The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 μL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98–100%) and specificity (84–98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests.
format Online
Article
Text
id pubmed-9176175
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-91761752022-06-09 An all-in-one point-of-care testing device for multiplexed detection of respiratory infections Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa, Javier Gimenez-Romero, David Maquieira, Ángel Morais, Sergi Biosens Bioelectron Article The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 μL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98–100%) and specificity (84–98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests. Elsevier B.V. 2022-10-01 2022-06-08 /pmc/articles/PMC9176175/ /pubmed/35696866 http://dx.doi.org/10.1016/j.bios.2022.114454 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Teixeira, William
Pallás-Tamarit, Yeray
Juste-Dolz, Augusto
Sena-Torralba, Amadeo
Gozalbo-Rovira, Roberto
Rodríguez-Díaz, Jesús
Navarro, David
Carrascosa, Javier
Gimenez-Romero, David
Maquieira, Ángel
Morais, Sergi
An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title_full An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title_fullStr An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title_full_unstemmed An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title_short An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
title_sort all-in-one point-of-care testing device for multiplexed detection of respiratory infections
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176175/
https://www.ncbi.nlm.nih.gov/pubmed/35696866
http://dx.doi.org/10.1016/j.bios.2022.114454
work_keys_str_mv AT teixeirawilliam anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT pallastamarityeray anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT justedolzaugusto anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT senatorralbaamadeo anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT gozalboroviraroberto anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT rodriguezdiazjesus anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT navarrodavid anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT carrascosajavier anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT gimenezromerodavid anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT maquieiraangel anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT moraissergi anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT teixeirawilliam allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT pallastamarityeray allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT justedolzaugusto allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT senatorralbaamadeo allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT gozalboroviraroberto allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT rodriguezdiazjesus allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT navarrodavid allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT carrascosajavier allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT gimenezromerodavid allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT maquieiraangel allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections
AT moraissergi allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections