Cargando…
An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approac...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176175/ https://www.ncbi.nlm.nih.gov/pubmed/35696866 http://dx.doi.org/10.1016/j.bios.2022.114454 |
_version_ | 1784722608033366016 |
---|---|
author | Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa, Javier Gimenez-Romero, David Maquieira, Ángel Morais, Sergi |
author_facet | Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa, Javier Gimenez-Romero, David Maquieira, Ángel Morais, Sergi |
author_sort | Teixeira, William |
collection | PubMed |
description | The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 μL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98–100%) and specificity (84–98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests. |
format | Online Article Text |
id | pubmed-9176175 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-91761752022-06-09 An all-in-one point-of-care testing device for multiplexed detection of respiratory infections Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa, Javier Gimenez-Romero, David Maquieira, Ángel Morais, Sergi Biosens Bioelectron Article The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 μL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98–100%) and specificity (84–98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests. Elsevier B.V. 2022-10-01 2022-06-08 /pmc/articles/PMC9176175/ /pubmed/35696866 http://dx.doi.org/10.1016/j.bios.2022.114454 Text en © 2022 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Teixeira, William Pallás-Tamarit, Yeray Juste-Dolz, Augusto Sena-Torralba, Amadeo Gozalbo-Rovira, Roberto Rodríguez-Díaz, Jesús Navarro, David Carrascosa, Javier Gimenez-Romero, David Maquieira, Ángel Morais, Sergi An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title | An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title_full | An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title_fullStr | An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title_full_unstemmed | An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title_short | An all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
title_sort | all-in-one point-of-care testing device for multiplexed detection of respiratory infections |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176175/ https://www.ncbi.nlm.nih.gov/pubmed/35696866 http://dx.doi.org/10.1016/j.bios.2022.114454 |
work_keys_str_mv | AT teixeirawilliam anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT pallastamarityeray anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT justedolzaugusto anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT senatorralbaamadeo anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT gozalboroviraroberto anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT rodriguezdiazjesus anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT navarrodavid anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT carrascosajavier anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT gimenezromerodavid anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT maquieiraangel anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT moraissergi anallinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT teixeirawilliam allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT pallastamarityeray allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT justedolzaugusto allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT senatorralbaamadeo allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT gozalboroviraroberto allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT rodriguezdiazjesus allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT navarrodavid allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT carrascosajavier allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT gimenezromerodavid allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT maquieiraangel allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections AT moraissergi allinonepointofcaretestingdeviceformultiplexeddetectionofrespiratoryinfections |