Cargando…

Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite

AIM: Evaluate the effect of different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface micro-hardness, and depth of cure of bulk-fill composite. METHODS: Bulk fill composite specimens of 4 mm depth, 4 mm width, and 4 mm length were prepared. Five groups were...

Descripción completa

Detalles Bibliográficos
Autores principales: Tirumala, Dabburi, Sravanthi, Tammineedi, Nagesh, Bolla, Sunil, Chukka Ram, Chowdary, Basam Ram, Swapnika, Polineni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iuliu Hatieganu University of Medicine and Pharmacy 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176310/
https://www.ncbi.nlm.nih.gov/pubmed/35721033
http://dx.doi.org/10.15386/mpr-2012
_version_ 1784722638088699904
author Tirumala, Dabburi
Sravanthi, Tammineedi
Nagesh, Bolla
Sunil, Chukka Ram
Chowdary, Basam Ram
Swapnika, Polineni
author_facet Tirumala, Dabburi
Sravanthi, Tammineedi
Nagesh, Bolla
Sunil, Chukka Ram
Chowdary, Basam Ram
Swapnika, Polineni
author_sort Tirumala, Dabburi
collection PubMed
description AIM: Evaluate the effect of different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface micro-hardness, and depth of cure of bulk-fill composite. METHODS: Bulk fill composite specimens of 4 mm depth, 4 mm width, and 4 mm length were prepared. Five groups were designed based on a light source under which composite samples were condensed. Group 1: dental chair light without filter, Group 2: microscopic light without filter, Group 3: microscopic light with a yellow filter, Group 4: microscopic light with a green filter, Group 5: dental chair light with a red filter. After condensation, the samples were subjected to curing using Bluephase NM curing light. The parameters like volumetric shrinkage, surface hardness, and depth of cure were measured for all the samples. The results were subjected to statistical analysis using one-way ANOVA, followed by post-hoc Tukey tests. RESULTS: Group-2 showed the highest mean volumetric shrinkage (14.514%), surface micro-hardness (58.065 kg/m2), depth of cure (0.831%), whereas group-5 showed the least volumetric shrinkage (7.386%), surface micro-hardness (46.536 kg/m(2)), and depth of cure (0.789%). Working time was 40 seconds for group-2, whereas the remaining groups were allowed to complete 1-minute condensation. A statistically significant difference was shown between groups 1 and 5 (p=0.050), 2 and 5 (p=0.007) for volumetric shrinkage. Regarding surface micro-hardness, a statistically significant difference was observed between all the groups (p=0.001) except group-3, group-4 (p=0.100). There was no statistically significant difference between all the groups except group 2 and 5 for depth of cure (p=0.016). CONCLUSION: Microscope light without filter showed the highest surface hardness and depth of cure. However, the highest volumetric shrinkage and lesser working time were also observed, which are undesirable. Use of filters during composite manipulation showed less detrimental effects on depth of cure, volumetric shrinkage and working time. Overall, composite condensed under filters showed acceptable properties.
format Online
Article
Text
id pubmed-9176310
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Iuliu Hatieganu University of Medicine and Pharmacy
record_format MEDLINE/PubMed
spelling pubmed-91763102022-06-17 Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite Tirumala, Dabburi Sravanthi, Tammineedi Nagesh, Bolla Sunil, Chukka Ram Chowdary, Basam Ram Swapnika, Polineni Med Pharm Rep Original Research AIM: Evaluate the effect of different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface micro-hardness, and depth of cure of bulk-fill composite. METHODS: Bulk fill composite specimens of 4 mm depth, 4 mm width, and 4 mm length were prepared. Five groups were designed based on a light source under which composite samples were condensed. Group 1: dental chair light without filter, Group 2: microscopic light without filter, Group 3: microscopic light with a yellow filter, Group 4: microscopic light with a green filter, Group 5: dental chair light with a red filter. After condensation, the samples were subjected to curing using Bluephase NM curing light. The parameters like volumetric shrinkage, surface hardness, and depth of cure were measured for all the samples. The results were subjected to statistical analysis using one-way ANOVA, followed by post-hoc Tukey tests. RESULTS: Group-2 showed the highest mean volumetric shrinkage (14.514%), surface micro-hardness (58.065 kg/m2), depth of cure (0.831%), whereas group-5 showed the least volumetric shrinkage (7.386%), surface micro-hardness (46.536 kg/m(2)), and depth of cure (0.789%). Working time was 40 seconds for group-2, whereas the remaining groups were allowed to complete 1-minute condensation. A statistically significant difference was shown between groups 1 and 5 (p=0.050), 2 and 5 (p=0.007) for volumetric shrinkage. Regarding surface micro-hardness, a statistically significant difference was observed between all the groups (p=0.001) except group-3, group-4 (p=0.100). There was no statistically significant difference between all the groups except group 2 and 5 for depth of cure (p=0.016). CONCLUSION: Microscope light without filter showed the highest surface hardness and depth of cure. However, the highest volumetric shrinkage and lesser working time were also observed, which are undesirable. Use of filters during composite manipulation showed less detrimental effects on depth of cure, volumetric shrinkage and working time. Overall, composite condensed under filters showed acceptable properties. Iuliu Hatieganu University of Medicine and Pharmacy 2022-04 2022-04-28 /pmc/articles/PMC9176310/ /pubmed/35721033 http://dx.doi.org/10.15386/mpr-2012 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
spellingShingle Original Research
Tirumala, Dabburi
Sravanthi, Tammineedi
Nagesh, Bolla
Sunil, Chukka Ram
Chowdary, Basam Ram
Swapnika, Polineni
Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title_full Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title_fullStr Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title_full_unstemmed Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title_short Effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
title_sort effect of the different chromatic filters of the dental operating microscope on the volumetric shrinkage, surface hardness, and depth of cure of bulk fill composite
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176310/
https://www.ncbi.nlm.nih.gov/pubmed/35721033
http://dx.doi.org/10.15386/mpr-2012
work_keys_str_mv AT tirumaladabburi effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite
AT sravanthitammineedi effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite
AT nageshbolla effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite
AT sunilchukkaram effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite
AT chowdarybasamram effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite
AT swapnikapolineni effectofthedifferentchromaticfiltersofthedentaloperatingmicroscopeonthevolumetricshrinkagesurfacehardnessanddepthofcureofbulkfillcomposite