Cargando…
Analytical evaluation of thirty-two severe acute respiratory syndrome 2 lateral flow antigen tests demonstrates sensitivity remains with the SARS-CoV-2 Gamma lineage
BACKGROUND: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. METHODS: A...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Medicina Tropical - SBMT
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9176730/ https://www.ncbi.nlm.nih.gov/pubmed/35674553 http://dx.doi.org/10.1590/0037-8682-0016-2022 |
Sumario: | BACKGROUND: The emergence of variants of concern (VOCs) requires an ongoing assessment of the performance of antigen lateral flow tests (Ag-RDTs). The limit of detection (LOD) of 32 Ag-RDTs was evaluated using the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Gamma variant. METHODS: Ag-RDTs were performed according to the manufacturer’s instructions with a clinical isolate of the Gamma variant. RESULTS: Twenty-eight of the 32 Ag-RDTs exceeded the World Health Organization criteria. CONCLUSIONS: This comprehensive analytical evaluation of Ag-RDTs demonstrated that the test performance was maintained with Gamma VOC. |
---|