Cargando…

Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration

IFAS systems are inherently complex due to the hybrid use of both suspended and attached bacterial colonies for the purpose of pollutant degradation as part of wastewater treatment. This poses challenges when attempting to represent these systems mathematically due to the vast number of parameters i...

Descripción completa

Detalles Bibliográficos
Autores principales: Pryce, D., Kapelan, Z., Memon, F. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9177546/
https://www.ncbi.nlm.nih.gov/pubmed/35676437
http://dx.doi.org/10.1038/s41598-022-13779-w
_version_ 1784722905208193024
author Pryce, D.
Kapelan, Z.
Memon, F. A.
author_facet Pryce, D.
Kapelan, Z.
Memon, F. A.
author_sort Pryce, D.
collection PubMed
description IFAS systems are inherently complex due to the hybrid use of both suspended and attached bacterial colonies for the purpose of pollutant degradation as part of wastewater treatment. This poses challenges when attempting to represent these systems mathematically due to the vast number of parameters involved. Besides becoming convoluted, large effort will be incurred during model calibration. This paper demonstrates a systematic approach to calibration of an IFAS process model that incorporates two sensitivity analyses to identify influential parameters and detect collinearity from a subset of 68 kinetic and stoichiometric parameters, and the use of the Nelder–Mead optimization algorithm to estimate the required values of these parameters. The model considers the removal of three critical pollutants including biochemical oxygen demand (BOD), total nitrogen (TN) and total suspended solids (TSS). Results from the sensitivity analyses identified four parameters that were the primary influence on the model. The model was found to be most sensitive to the two stoichiometric parameters including aerobic heterotrophic yield on soluble substrate whose total effects were responsible for 92.4% of the model’s BOD output sensitivity and 92.8% of the model’s TSS output sensitivity. The anoxic heterotrophic yield on soluble substrate was observed to be responsible for 54.3% of the model’s TN output sensitivity. To a lesser extent the two kinetic parameters, aerobic heterotrophic decay rate and reduction factor for denitrification on nitrite, were responsible for only 8.0% and 13.1% of the model’s BOD and TN output sensitivities respectively. Parameter estimation identified the need for only minor adjustments to default values in order to achieve sufficient accuracy of simulation with deviation from observed data to be only ± 3.6 mg/L, ± 1.3 mg/L, and ± 9.5 mg/L for BOD, TN and TSS respectively. Validation showed the model was limited in its capacity to predict system behaviour under extreme dissolved oxygen stress.
format Online
Article
Text
id pubmed-9177546
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-91775462022-06-10 Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration Pryce, D. Kapelan, Z. Memon, F. A. Sci Rep Article IFAS systems are inherently complex due to the hybrid use of both suspended and attached bacterial colonies for the purpose of pollutant degradation as part of wastewater treatment. This poses challenges when attempting to represent these systems mathematically due to the vast number of parameters involved. Besides becoming convoluted, large effort will be incurred during model calibration. This paper demonstrates a systematic approach to calibration of an IFAS process model that incorporates two sensitivity analyses to identify influential parameters and detect collinearity from a subset of 68 kinetic and stoichiometric parameters, and the use of the Nelder–Mead optimization algorithm to estimate the required values of these parameters. The model considers the removal of three critical pollutants including biochemical oxygen demand (BOD), total nitrogen (TN) and total suspended solids (TSS). Results from the sensitivity analyses identified four parameters that were the primary influence on the model. The model was found to be most sensitive to the two stoichiometric parameters including aerobic heterotrophic yield on soluble substrate whose total effects were responsible for 92.4% of the model’s BOD output sensitivity and 92.8% of the model’s TSS output sensitivity. The anoxic heterotrophic yield on soluble substrate was observed to be responsible for 54.3% of the model’s TN output sensitivity. To a lesser extent the two kinetic parameters, aerobic heterotrophic decay rate and reduction factor for denitrification on nitrite, were responsible for only 8.0% and 13.1% of the model’s BOD and TN output sensitivities respectively. Parameter estimation identified the need for only minor adjustments to default values in order to achieve sufficient accuracy of simulation with deviation from observed data to be only ± 3.6 mg/L, ± 1.3 mg/L, and ± 9.5 mg/L for BOD, TN and TSS respectively. Validation showed the model was limited in its capacity to predict system behaviour under extreme dissolved oxygen stress. Nature Publishing Group UK 2022-06-08 /pmc/articles/PMC9177546/ /pubmed/35676437 http://dx.doi.org/10.1038/s41598-022-13779-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Pryce, D.
Kapelan, Z.
Memon, F. A.
Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title_full Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title_fullStr Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title_full_unstemmed Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title_short Modelling the performance of an integrated fixed-film activated sludge (IFAS) system: a systematic approach to automated calibration
title_sort modelling the performance of an integrated fixed-film activated sludge (ifas) system: a systematic approach to automated calibration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9177546/
https://www.ncbi.nlm.nih.gov/pubmed/35676437
http://dx.doi.org/10.1038/s41598-022-13779-w
work_keys_str_mv AT pryced modellingtheperformanceofanintegratedfixedfilmactivatedsludgeifassystemasystematicapproachtoautomatedcalibration
AT kapelanz modellingtheperformanceofanintegratedfixedfilmactivatedsludgeifassystemasystematicapproachtoautomatedcalibration
AT memonfa modellingtheperformanceofanintegratedfixedfilmactivatedsludgeifassystemasystematicapproachtoautomatedcalibration