Cargando…

Veno-Arterial Extracorporeal Membrane Oxygenation in Elective High-Risk Percutaneous Coronary Interventions

BACKGROUND: The safety and feasibility of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) as mechanical circulatory support in high-risk percutaneous coronary intervention (HR-PCI) remain unclear. METHODS: This retrospective study included patients with complex and high-risk coronary art...

Descripción completa

Detalles Bibliográficos
Autores principales: Bai, Ming, Lu, Andong, Pan, Chenliang, Hu, Sixiong, Qu, Wenjing, Zhao, Jing, Zhang, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9178105/
https://www.ncbi.nlm.nih.gov/pubmed/35692539
http://dx.doi.org/10.3389/fmed.2022.913403
Descripción
Sumario:BACKGROUND: The safety and feasibility of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) as mechanical circulatory support in high-risk percutaneous coronary intervention (HR-PCI) remain unclear. METHODS: This retrospective study included patients with complex and high-risk coronary artery disease who underwent elective PCI with VA-ECMO support pre-operatively during March 2019–December 2020. Rates of VA-ECMO-related complications, complications during PCI, death, myocardial infarction, and stroke during hospitalisation and 1-year post-operatively were analysed. RESULTS: Overall, 36 patients (average age: 63.6 ± 8.9 years) underwent PCI. The average duration of VA-ECMO support was 12.5 (range, 3.0–26.3) h. Intra-aortic balloon pump counterpulsation was used in 44.4% of patients. The SYNTAX score was 34.6 ± 8.4 pre-operatively and 10.8 ± 8.8 post-operatively (P < 0.001). Intraoperative complications included pericardial tamponade (N = 2, 5.6%), acute left-sided heart failure (N = 1, 2.8%), malignant arrhythmia requiring electrocardioversion (N = 2, 5.6%), and no deaths. Blood haemoglobin levels before PCI and 24 h after VA-ECMO withdrawal were 145.4 ± 20.2 g/L and 105.7 ± 21.7 g/L, respectively (P < 0.001). Outcomes during hospitalisation included death (N = 1, 2.8%), stroke (N = 1, 2.8%), lower limb ischaemia (N = 2, 5.6%), lower limb deep venous thrombosis (N = 1, 2.8%), cannulation site haematoma (N = 2, 5.6%), acute renal injury (N = 2, 5.6%), bacteraemia (N = 2, 5.6%), bleeding requiring blood transfusion (N = 5, 13.9%), and no recurrent myocardial infarctions. Within 1 year post-operatively, two patients (5.6%) were hospitalised for heart failure. CONCLUSIONS: Veno-arterial extracorporeal membrane oxygenation mechanical circulation support during HR-PCI is a safe and feasible strategy for achieving revascularisation in complex and high-risk coronary artery lesions. VA-ECMO-related complications require special attention.