A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft

We describe an infrequent case of endoleak Type-III due to an unrecognized, inadvertent bilateral limb deployment into the same limb gate of the Ovation aortic endograft, accompanied by thrombosis and acute ischemia. The following computed tomography angiography revealed the open limb gate with the...

Descripción completa

Detalles Bibliográficos
Autores principales: Georgakarakos, Efstratios, Koutsoumpelis, Andreas, Kostoglou, Panagiotis, Tasopoulou, Kalliopi-Maria, Argyriou, Christos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers, Inc. 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9179207/
https://www.ncbi.nlm.nih.gov/pubmed/35640586
http://dx.doi.org/10.1055/s-0042-1743197
_version_ 1784723217993170944
author Georgakarakos, Efstratios
Koutsoumpelis, Andreas
Kostoglou, Panagiotis
Tasopoulou, Kalliopi-Maria
Argyriou, Christos
author_facet Georgakarakos, Efstratios
Koutsoumpelis, Andreas
Kostoglou, Panagiotis
Tasopoulou, Kalliopi-Maria
Argyriou, Christos
author_sort Georgakarakos, Efstratios
collection PubMed
description We describe an infrequent case of endoleak Type-III due to an unrecognized, inadvertent bilateral limb deployment into the same limb gate of the Ovation aortic endograft, accompanied by thrombosis and acute ischemia. The following computed tomography angiography revealed the open limb gate with the characteristic of radio-opaque polymer in the sealing rings. Intraoperative angiographies via the brachial route identified the open limb gate and facilitated the successful use of an occluding plug to manage the Type-III endoleak.
format Online
Article
Text
id pubmed-9179207
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Thieme Medical Publishers, Inc.
record_format MEDLINE/PubMed
spelling pubmed-91792072022-06-10 A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft Georgakarakos, Efstratios Koutsoumpelis, Andreas Kostoglou, Panagiotis Tasopoulou, Kalliopi-Maria Argyriou, Christos Aorta (Stamford) We describe an infrequent case of endoleak Type-III due to an unrecognized, inadvertent bilateral limb deployment into the same limb gate of the Ovation aortic endograft, accompanied by thrombosis and acute ischemia. The following computed tomography angiography revealed the open limb gate with the characteristic of radio-opaque polymer in the sealing rings. Intraoperative angiographies via the brachial route identified the open limb gate and facilitated the successful use of an occluding plug to manage the Type-III endoleak. Thieme Medical Publishers, Inc. 2022-05-31 /pmc/articles/PMC9179207/ /pubmed/35640586 http://dx.doi.org/10.1055/s-0042-1743197 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ) https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Georgakarakos, Efstratios
Koutsoumpelis, Andreas
Kostoglou, Panagiotis
Tasopoulou, Kalliopi-Maria
Argyriou, Christos
A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title_full A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title_fullStr A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title_full_unstemmed A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title_short A Misdiagnosed Case of Endoleak Type-III Caused by Inadvertent Bilateral Limb Insertion in the Same Limb Gate of the Ovation Endograft
title_sort misdiagnosed case of endoleak type-iii caused by inadvertent bilateral limb insertion in the same limb gate of the ovation endograft
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9179207/
https://www.ncbi.nlm.nih.gov/pubmed/35640586
http://dx.doi.org/10.1055/s-0042-1743197
work_keys_str_mv AT georgakarakosefstratios amisdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT koutsoumpelisandreas amisdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT kostogloupanagiotis amisdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT tasopouloukalliopimaria amisdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT argyriouchristos amisdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT georgakarakosefstratios misdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT koutsoumpelisandreas misdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT kostogloupanagiotis misdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT tasopouloukalliopimaria misdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft
AT argyriouchristos misdiagnosedcaseofendoleaktypeiiicausedbyinadvertentbilaterallimbinsertioninthesamelimbgateoftheovationendograft