Cargando…

Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep

This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Ye Min Soe, Kay Thwe, Ishiyama, Hiroyuki, Nishiyama, Akira, Shimada, Masahiko, Maeda, Shigeru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9180795/
https://www.ncbi.nlm.nih.gov/pubmed/35682298
http://dx.doi.org/10.3390/ijerph19116714
_version_ 1784723608366481408
author Ye Min Soe, Kay Thwe
Ishiyama, Hiroyuki
Nishiyama, Akira
Shimada, Masahiko
Maeda, Shigeru
author_facet Ye Min Soe, Kay Thwe
Ishiyama, Hiroyuki
Nishiyama, Akira
Shimada, Masahiko
Maeda, Shigeru
author_sort Ye Min Soe, Kay Thwe
collection PubMed
description This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 13) and without OSA (w/o-OSA) (n = 10). Three types of MOAs, standard-OA (S-OA), palatal covering-OA (PC-OA), and vertically increasing-OA (VI-OA), were each worn for three nights, and sleep tests with each MOA were performed with a portable device for two nights. Based on the average of the respiratory event index (REI) values for the two nights for each MOA, w/o-OSA participants with an REI ≥ 5.0 were defined as the exacerbation group and those with an REI < 5.0 as the non-exacerbation group. In mild-OSA participants, an REI ≥ 15.0 or REI ≥ baseline REI × 1.5 were defined as the exacerbation group and those with an REI < 15.0 and REI < baseline REI × 1.5 were defined as the non-exacerbation group. The percentage of the exacerbation and non-exacerbation groups with MOA was evaluated in the w/o-OSA and mild-OSA participants. The maxillary and mandibular dental-arch dimension was compared by dentition model analysis. The exacerbation group in w/o-OSA participants (n = 10) comprised 10.0% participants (n = 1) with S-OA, 40.0% (n = 4) with PC-OA, and 30.0% (n = 3) with VI-OA. The exacerbation group in the mild-OSA participants (n = 13) comprised 15.4% subjects (n = 2) with S-OA, 23.1% (n = 3) with PC-OA, and 23.1% (n = 3) in VI-OA. In the model analysis for w/o-OSA, the posterior dental arch width was significantly greater in the exacerbation group than in the non-exacerbation group wearing S-OA (p < 0.05). In addition, the ratio of the maxillary to mandibular dental arch width (anterior dental arch width) was significantly greater in the exacerbation group than in the non-exacerbation group for both PC-OA and VI-OA (p < 0.05). In mild-OSA, the maxillary and mandibular dental arch lengths and the ratio of maxillary to mandibular dental arch width (posterior dental arch width) were significantly smaller in the exacerbation group than in the non-exacerbation group for S-OA (p < 0.05). This study confirmed that wearing an MOA by w/o-OSA and mild-OSA participants may increase the REI during sleep and that PC-OA and VI-OA may increase the REI more than S-OA. The maxillary and mandibular dental-arch dimensions may affect the REI when using an MOA.
format Online
Article
Text
id pubmed-9180795
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91807952022-06-10 Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep Ye Min Soe, Kay Thwe Ishiyama, Hiroyuki Nishiyama, Akira Shimada, Masahiko Maeda, Shigeru Int J Environ Res Public Health Article This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 13) and without OSA (w/o-OSA) (n = 10). Three types of MOAs, standard-OA (S-OA), palatal covering-OA (PC-OA), and vertically increasing-OA (VI-OA), were each worn for three nights, and sleep tests with each MOA were performed with a portable device for two nights. Based on the average of the respiratory event index (REI) values for the two nights for each MOA, w/o-OSA participants with an REI ≥ 5.0 were defined as the exacerbation group and those with an REI < 5.0 as the non-exacerbation group. In mild-OSA participants, an REI ≥ 15.0 or REI ≥ baseline REI × 1.5 were defined as the exacerbation group and those with an REI < 15.0 and REI < baseline REI × 1.5 were defined as the non-exacerbation group. The percentage of the exacerbation and non-exacerbation groups with MOA was evaluated in the w/o-OSA and mild-OSA participants. The maxillary and mandibular dental-arch dimension was compared by dentition model analysis. The exacerbation group in w/o-OSA participants (n = 10) comprised 10.0% participants (n = 1) with S-OA, 40.0% (n = 4) with PC-OA, and 30.0% (n = 3) with VI-OA. The exacerbation group in the mild-OSA participants (n = 13) comprised 15.4% subjects (n = 2) with S-OA, 23.1% (n = 3) with PC-OA, and 23.1% (n = 3) in VI-OA. In the model analysis for w/o-OSA, the posterior dental arch width was significantly greater in the exacerbation group than in the non-exacerbation group wearing S-OA (p < 0.05). In addition, the ratio of the maxillary to mandibular dental arch width (anterior dental arch width) was significantly greater in the exacerbation group than in the non-exacerbation group for both PC-OA and VI-OA (p < 0.05). In mild-OSA, the maxillary and mandibular dental arch lengths and the ratio of maxillary to mandibular dental arch width (posterior dental arch width) were significantly smaller in the exacerbation group than in the non-exacerbation group for S-OA (p < 0.05). This study confirmed that wearing an MOA by w/o-OSA and mild-OSA participants may increase the REI during sleep and that PC-OA and VI-OA may increase the REI more than S-OA. The maxillary and mandibular dental-arch dimensions may affect the REI when using an MOA. MDPI 2022-05-31 /pmc/articles/PMC9180795/ /pubmed/35682298 http://dx.doi.org/10.3390/ijerph19116714 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ye Min Soe, Kay Thwe
Ishiyama, Hiroyuki
Nishiyama, Akira
Shimada, Masahiko
Maeda, Shigeru
Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title_full Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title_fullStr Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title_full_unstemmed Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title_short Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
title_sort effect of different maxillary oral appliance designs on respiratory variables during sleep
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9180795/
https://www.ncbi.nlm.nih.gov/pubmed/35682298
http://dx.doi.org/10.3390/ijerph19116714
work_keys_str_mv AT yeminsoekaythwe effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep
AT ishiyamahiroyuki effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep
AT nishiyamaakira effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep
AT shimadamasahiko effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep
AT maedashigeru effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep