Cargando…
Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep
This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 1...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9180795/ https://www.ncbi.nlm.nih.gov/pubmed/35682298 http://dx.doi.org/10.3390/ijerph19116714 |
_version_ | 1784723608366481408 |
---|---|
author | Ye Min Soe, Kay Thwe Ishiyama, Hiroyuki Nishiyama, Akira Shimada, Masahiko Maeda, Shigeru |
author_facet | Ye Min Soe, Kay Thwe Ishiyama, Hiroyuki Nishiyama, Akira Shimada, Masahiko Maeda, Shigeru |
author_sort | Ye Min Soe, Kay Thwe |
collection | PubMed |
description | This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 13) and without OSA (w/o-OSA) (n = 10). Three types of MOAs, standard-OA (S-OA), palatal covering-OA (PC-OA), and vertically increasing-OA (VI-OA), were each worn for three nights, and sleep tests with each MOA were performed with a portable device for two nights. Based on the average of the respiratory event index (REI) values for the two nights for each MOA, w/o-OSA participants with an REI ≥ 5.0 were defined as the exacerbation group and those with an REI < 5.0 as the non-exacerbation group. In mild-OSA participants, an REI ≥ 15.0 or REI ≥ baseline REI × 1.5 were defined as the exacerbation group and those with an REI < 15.0 and REI < baseline REI × 1.5 were defined as the non-exacerbation group. The percentage of the exacerbation and non-exacerbation groups with MOA was evaluated in the w/o-OSA and mild-OSA participants. The maxillary and mandibular dental-arch dimension was compared by dentition model analysis. The exacerbation group in w/o-OSA participants (n = 10) comprised 10.0% participants (n = 1) with S-OA, 40.0% (n = 4) with PC-OA, and 30.0% (n = 3) with VI-OA. The exacerbation group in the mild-OSA participants (n = 13) comprised 15.4% subjects (n = 2) with S-OA, 23.1% (n = 3) with PC-OA, and 23.1% (n = 3) in VI-OA. In the model analysis for w/o-OSA, the posterior dental arch width was significantly greater in the exacerbation group than in the non-exacerbation group wearing S-OA (p < 0.05). In addition, the ratio of the maxillary to mandibular dental arch width (anterior dental arch width) was significantly greater in the exacerbation group than in the non-exacerbation group for both PC-OA and VI-OA (p < 0.05). In mild-OSA, the maxillary and mandibular dental arch lengths and the ratio of maxillary to mandibular dental arch width (posterior dental arch width) were significantly smaller in the exacerbation group than in the non-exacerbation group for S-OA (p < 0.05). This study confirmed that wearing an MOA by w/o-OSA and mild-OSA participants may increase the REI during sleep and that PC-OA and VI-OA may increase the REI more than S-OA. The maxillary and mandibular dental-arch dimensions may affect the REI when using an MOA. |
format | Online Article Text |
id | pubmed-9180795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91807952022-06-10 Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep Ye Min Soe, Kay Thwe Ishiyama, Hiroyuki Nishiyama, Akira Shimada, Masahiko Maeda, Shigeru Int J Environ Res Public Health Article This study aimed to analyze the efficacy of maxillary oral appliance (MOA) designs on respiratory variables during sleep. At baseline, 23 participants underwent a sleep test with a portable device for two nights and were categorized as participants with mild obstructive sleep apnea (mild-OSA) (n = 13) and without OSA (w/o-OSA) (n = 10). Three types of MOAs, standard-OA (S-OA), palatal covering-OA (PC-OA), and vertically increasing-OA (VI-OA), were each worn for three nights, and sleep tests with each MOA were performed with a portable device for two nights. Based on the average of the respiratory event index (REI) values for the two nights for each MOA, w/o-OSA participants with an REI ≥ 5.0 were defined as the exacerbation group and those with an REI < 5.0 as the non-exacerbation group. In mild-OSA participants, an REI ≥ 15.0 or REI ≥ baseline REI × 1.5 were defined as the exacerbation group and those with an REI < 15.0 and REI < baseline REI × 1.5 were defined as the non-exacerbation group. The percentage of the exacerbation and non-exacerbation groups with MOA was evaluated in the w/o-OSA and mild-OSA participants. The maxillary and mandibular dental-arch dimension was compared by dentition model analysis. The exacerbation group in w/o-OSA participants (n = 10) comprised 10.0% participants (n = 1) with S-OA, 40.0% (n = 4) with PC-OA, and 30.0% (n = 3) with VI-OA. The exacerbation group in the mild-OSA participants (n = 13) comprised 15.4% subjects (n = 2) with S-OA, 23.1% (n = 3) with PC-OA, and 23.1% (n = 3) in VI-OA. In the model analysis for w/o-OSA, the posterior dental arch width was significantly greater in the exacerbation group than in the non-exacerbation group wearing S-OA (p < 0.05). In addition, the ratio of the maxillary to mandibular dental arch width (anterior dental arch width) was significantly greater in the exacerbation group than in the non-exacerbation group for both PC-OA and VI-OA (p < 0.05). In mild-OSA, the maxillary and mandibular dental arch lengths and the ratio of maxillary to mandibular dental arch width (posterior dental arch width) were significantly smaller in the exacerbation group than in the non-exacerbation group for S-OA (p < 0.05). This study confirmed that wearing an MOA by w/o-OSA and mild-OSA participants may increase the REI during sleep and that PC-OA and VI-OA may increase the REI more than S-OA. The maxillary and mandibular dental-arch dimensions may affect the REI when using an MOA. MDPI 2022-05-31 /pmc/articles/PMC9180795/ /pubmed/35682298 http://dx.doi.org/10.3390/ijerph19116714 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ye Min Soe, Kay Thwe Ishiyama, Hiroyuki Nishiyama, Akira Shimada, Masahiko Maeda, Shigeru Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title | Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title_full | Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title_fullStr | Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title_full_unstemmed | Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title_short | Effect of Different Maxillary Oral Appliance Designs on Respiratory Variables during Sleep |
title_sort | effect of different maxillary oral appliance designs on respiratory variables during sleep |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9180795/ https://www.ncbi.nlm.nih.gov/pubmed/35682298 http://dx.doi.org/10.3390/ijerph19116714 |
work_keys_str_mv | AT yeminsoekaythwe effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep AT ishiyamahiroyuki effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep AT nishiyamaakira effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep AT shimadamasahiko effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep AT maedashigeru effectofdifferentmaxillaryoralappliancedesignsonrespiratoryvariablesduringsleep |